Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-04-03
|
Emphasis |
L: FORKLIFT, N: AMPUTATE, N: DUSTEXPL
|
Case Closed |
2014-11-20
|
Related Activity
Type |
Complaint |
Activity Nr |
878345 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
965839 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2014-07-30 |
Abatement Due Date |
2014-09-16 |
Current Penalty |
3500.0 |
Initial Penalty |
5000.0 |
Final Order |
2014-08-20 |
Nr Instances |
1 |
Nr Exposed |
103 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that caused or were likely to cause death or serious physical harm in that employees were exposed to combustible dust explosion, deflagration, or other fire hazards while working at or near dust collection system which were not adequately designed to prevent or minimize employee exposure in the event of a deflagration or other uncontrolled fire event: (a) 115 Ford Street in Pontotoc, MS - On or about April 3, 2014, employees were exposed to combustible dust fire and explosion hazards due to the employer's failure to protect the three dust collection systems with isolation devices. (b) 115 Ford Street in Pontotoc, MS - On or about April 3, 2014, employees were exposed to combustible dust fire and explosion hazards due to the employer's failure to provide permanent grounding and bonding of the outside storage trailers/bins subject to the accumulation of static electric charge. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 C02 I |
Issuance Date |
2014-07-30 |
Abatement Due Date |
2014-08-18 |
Current Penalty |
1500.0 |
Initial Penalty |
5000.0 |
Final Order |
2014-08-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) 115 Ford Street in Pontotoc, MS - On or about April 3, 2014, the horizontal shaft on the blower/exhaust fan for number 3 cyclone/bag house was not guarded to prevent employees from contacting the shaft. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100219 D01 |
Issuance Date |
2014-07-30 |
Abatement Due Date |
2014-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-08-20 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) 115 Ford Street in Pontotoc, MS - On or about April 3, 2014, the pulleys on the motor and blower/exhaust fan for cyclone/bag-house number 1 were not guarded on the back side. (b) 115 Ford Street in Pontotoc, MS - On or about April 3, 2014, the pulleys on the motor and blower/exhaust fan for cyclone/bag-house number 3 were not guarded on the back side. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100219 E03 I |
Issuance Date |
2014-07-30 |
Abatement Due Date |
2014-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-08-20 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): (a) 115 Ford Street in Pontotoc, MS - On or about April 3, 2014, the belts on the motor and blower/exhaust fan for cyclone/bag-house number 1 were not enclosed by a guard. (b) 115 Ford Street in Pontotoc, MS - On or about April 3, 2014, the belts on the motor and blower/exhaust fan for cyclone/bag-house number 3 were not enclosed by a guard. |
|
|