Search icon

Rio Lindo of Senatobia LLC

Company Details

Name: Rio Lindo of Senatobia LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Good Standing
Effective Date: 14 Aug 2012 (13 years ago)
Business ID: 1006690
ZIP code: 38668
County: Tate
State of Incorporation: MISSISSIPPI
Principal Office Address: 329 E MAIN ST, PO BOX 1450SENATOBIA, MS 38668

Agent

Name Role Address
Vital, Ricardo Agent 187 E Statelind Rd# 4;Po Box 1450, Southaven, MS 38671

Member

Name Role Address
Ricardo Vital Member PO BOX 1450, SOUTHAVEN, MS 38671

Filings

Type Status Filed Date Description
Annual Report LLC Filed 2024-03-12 Annual Report For Rio Lindo of Senatobia LLC
Annual Report LLC Filed 2023-03-17 Annual Report For Rio Lindo of Senatobia LLC
Annual Report LLC Filed 2022-03-21 Annual Report For Rio Lindo of Senatobia LLC
Annual Report LLC Filed 2021-03-09 Annual Report For Rio Lindo of Senatobia LLC
Annual Report LLC Filed 2020-08-21 Annual Report For Rio Lindo of Senatobia LLC
Annual Report LLC Filed 2019-03-28 Annual Report For Rio Lindo of Senatobia LLC
Reinstatement Filed 2019-03-19 Reinstatement For Rio Lindo of Senatobia LLC
Admin Dissolution Filed 2018-12-10 Admin Dissolution: AR
Notice to Dissolve/Revoke Filed 2018-09-07 Notice to Dissolve/Revoke
Annual Report LLC Filed 2017-06-14 Annual Report For Rio Lindo of Senatobia LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343177358 0419400 2018-05-03 329 E MAIN ST., SENATOBIA, MS, 38668
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2018-05-03
Case Closed 2018-05-23

Related Activity

Type Inspection
Activity Nr 1286428
Safety Yes
342864287 0419400 2018-01-04 329 E MAIN ST., SENATOBIA, MS, 38668
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2018-01-04
Case Closed 2018-05-23

Related Activity

Type Complaint
Activity Nr 1296799
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100303 B07 IV
Issuance Date 2018-03-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 6
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: (a) Kitchen - On or about January 4, 2018 Phillips multi-tap outlet's plastic cover was damaged.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100304 G05
Issuance Date 2018-03-23
Abatement Due Date 2018-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 6
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: (a) Kitchen - On or about January 4, 2018 the following equipment with all metal surfaces were not grounded: chip warmer, fountain machine, refrigerator and 2 sandwich tables.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100305 G01 IV A
Issuance Date 2018-03-23
Abatement Due Date 2018-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 6
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Kitchen - On or about January 4, 2018 an extension cord connected to a Phillips multi-tap outlet was used to power the chip warmer.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100305 G01 IV B
Issuance Date 2018-03-23
Abatement Due Date 2018-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 6
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: (a) Kitchen - On or about January 4, 2018 an extension cord powering the chip warmer was run through the ceiling.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2018-03-23
Abatement Due Date 2018-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 6
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) Kitchen - On or about January 4, 2018 plug attachment on cord powering the chip warmer metal clamp for strain relief was not fastened properly and did not provide strain relief.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2018-03-23
Abatement Due Date 2018-04-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Restaurant - On or about January 4, 2018 the employer had not developed a hazard communication program and employees use chemical products such as, but not limited to, bleach and Pine Sol.
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 G08
Issuance Date 2018-03-23
Abatement Due Date 2018-04-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: (a) Restaurant - On or about January 4, 2018 the employer did not have safety data sheets for chemical products such as, but not limited to, bleach and Pine Sol.
Citation ID 02003
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2018-03-23
Abatement Due Date 2018-04-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Restaurant - On or about January 4, 2018 the employer had not trained employees as required.

Date of last update: 25 Mar 2025