Search icon

Maple Land and Timber LLC

Company Details

Name: Maple Land and Timber LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Good Standing
Effective Date: 28 Sep 2012 (12 years ago)
Business ID: 1008927
ZIP code: 38824
County: Prentiss
State of Incorporation: MISSISSIPPI
Principal Office Address: 257 Hwy 30 WestBaldwyn, MS 38824

Agent

Name Role Address
Karen Edge Agent 405 W College St, PO Box 328, Booneville, MS 38829

Organizer

Name Role Address
Dipen M Shah Organizer 10576 ARCOLE COURT, WELLINGTON, FL 33449

Manager

Name Role Address
Dipen Shah Manager 14415 Seattle Slew Lane, Sun City, FL 33573

Member

Name Role Address
Dipen Shah Member 14415 Seattle Slew Lane, Sun City, FL 33573

Filings

Type Status Filed Date Description
Annual Report LLC Filed 2024-03-06 Annual Report For Maple Land and Timber LLC
Annual Report LLC Filed 2023-01-31 Annual Report For Maple Land and Timber LLC
Annual Report LLC Filed 2022-08-31 Annual Report For Maple Land and Timber LLC
Annual Report LLC Filed 2021-09-16 Annual Report For Maple Land and Timber LLC
Notice to Dissolve/Revoke Filed 2021-09-07 Notice of Intent to Dissolve: AR: Maple Land and Timber LLC
Annual Report LLC Filed 2020-03-31 Annual Report For Maple Land and Timber LLC
Amendment Form Filed 2020-03-10 Amendment For Maple Land and Timber LLC
Agent Resignation Filed 2019-11-12 Agent Resignation For
Annual Report LLC Filed 2019-04-12 Annual Report For Maple Land and Timber LLC
Amendment Form Filed 2018-11-13 Amendment For Maple Land and Timber LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339600751 0419400 2014-02-25 257 HWY 30 W., BALDWYN, MS, 38824
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-02-25
Emphasis L: FALL, N: AMPUTATE
Case Closed 2019-03-25

Related Activity

Type Complaint
Activity Nr 873411
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100219 D01
Issuance Date 2014-03-18
Abatement Due Date 2014-04-11
Current Penalty 2450.0
Initial Penalty 4900.0
Final Order 2014-04-11
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Mill No.1 and Mill No. 2 - On or about February 25, 2014 employees were exposed to amputation hazards while working near motor drive pulley systems. Pulleys and belts were not guarded on the following: (1) Mill No. 1, West End - Wood chipper/hog. (2) Mill No. 1, Saw Carriage - Main drive pulley system (3) Mill No. 1, East Side - Two piston type air compressor main drive pulley systems. (4) Mill No. 2, Saw Carriage Platform, West Side - Two motor drive pulley systems.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100265 C04 II
Issuance Date 2014-03-18
Abatement Due Date 2014-04-04
Current Penalty 2100.0
Initial Penalty 4200.0
Final Order 2014-04-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.265(c)(4)(ii): Walkway(s) were not evenly floored: (a) Mill No. 1, Saw Carriage Area, East End - On or about February 25, 2014 employees were exposed to a 6 foot fall hazard while accessing or egressing the saw carriage. The walkway did not have an evenly floored expanded metal platform.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100265 C04 IV
Issuance Date 2014-03-18
Abatement Due Date 2014-04-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.265(c)(4)(iv): Elevated platform(s), 4 feet or more from the floor level, were not provided with a standard railing: (a) Mill No. 1, Saw Carriage Area, East End - On or about February 25, 2014 employees were exposed to a 6 foot fall hazard while accessing or egressing the saw carriage area. Elevated platform did not have standard railings.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100265 C05 II
Issuance Date 2014-03-18
Abatement Due Date 2014-04-11
Current Penalty 2100.0
Initial Penalty 4200.0
Final Order 2014-04-11
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.265(c)(5)(ii): Stairways were not provided with a standard handrail on at least one side or on any open side: (a) Mill No. 1, Saw Carriage Access Platform, East Side - On or about February 25, 2014 employees were exposed to a 6 foot fall hazard while using a stair to access or egress the saw carriage platform. Standard handrails were not provided on each open side of stair. (b) Mill No. 2, Saw Carriage Platform, West Side - On or about February 25, 2014 employees were exposed to a 36 inch fall hazard while using a stair to access or egress the saw carriage platform. Standard handrails were not provided on each open side of stair.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100265 C18 I
Issuance Date 2014-03-18
Abatement Due Date 2014-04-11
Current Penalty 1750.0
Initial Penalty 3500.0
Final Order 2014-04-11
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.265(c)(18)(i): Pulley(s), sprocket(s), sheave(s), drum(s) and block(s) of conveyor(s) were not arranged to prevent the possibility of injury due to hands or parts of clothing being caught between the belt(s) and pulley(s) or chain(s) and sprockets: (a) Mill No. 1, Outfeed Conveyor - On or about February 25, 2014 employees were exposed to amputation hazards from ingoing nip points while working near the chain outfeed conveyor. There was no guard protecting employees from getting caught in running nip points.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100333 C03 I A 1
Issuance Date 2014-03-18
Abatement Due Date 2014-05-02
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2014-04-11
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.333(c)(3)(i)(A)(1): When an unqualified person was working in an elevated position near overhead lines with voltages to ground rated at 50 kV or below, the location was not such that the person and the longest conductive object he or she could contact was 10 feet or more from the overhead lines: (a) Mill No. 1, Log Deck - On or about February 25, 2014 an employee was exposed to electric shock hazard from overhead electric power lines while using a stationary mount loader to load logs onto Mill No. 1's log deck. The conductive loader boom was located within 10 feet of overhead electric power lines.
Citation ID 02001
Citaton Type Other
Standard Cited 19100106 B06
Issuance Date 2014-03-18
Abatement Due Date 2014-04-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-11
Nr Instances 1
Nr Exposed 14
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(b)(6): In locations where flammable vapors may be present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition. Sources of ignition may include open flames, lightning, smoking, hot surfaces, frictional heat, sparks (static, electrical, and mechanical), spontaneous ignition, chemical and physical-chemical reactions, and radiant heat: (a) Mill No. 2, South Side - On or about February 25, 2014 employees were exposed to fire hazards while working near or walking by an aboveground diesel fuel tank. "No Smoking" signs were not posted.
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2014-03-18
Abatement Due Date 2014-05-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-11
Nr Instances 1
Nr Exposed 14
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Sawmill - On or about February 25, 2014 employees were exposed to hazardous chemicals, such as, motor oil, hydraulic fluid and diesel fuel. The employer had not developed a written hazard communication program.

Date of last update: 16 Feb 2025

Sources: Mississippi Secretary of State