Search icon

ITRON, INC

Company Details

Name: ITRON, INC
Jurisdiction: MISSISSIPPI
Business Type: Profit Corporation
Status: Withdrawn
Effective Date: 25 Oct 2012 (12 years ago)
Business ID: 1010280
State of Incorporation: WASHINGTON
Principal Office Address: 2111 North Molter RoadLiberty Lake, WA 99019

Agent

Name Role Address
NATIONAL REGISTERED AGENTS INC Agent 645 Lakeland East Drive, Suite 101, Flowood, MS 39232

Director

Name Role Address
Philip Mezey Director 2111 North Molter Road, Liberty Lake, WA 99019
Jon Eliassen Director 2111 North Molter Road, Liberty Lake, WA 99019
Kirby Dyess Director 2111 North Molter Road, Liberty Lake, WA 99019
Charles Gaylord Director 2111 North Molter Road, Liberty Lake, WA 99019
Thomas Glanville Director 2111 North Molter Road, Liberty Lake, WA 99019
Sharon Nelson Director 2111 North Molter Road, Liberty Lake, WA 99019
Gary Pruitt Director 2111 North Molter Road, Liberty Lake, WA 99019
Graham Wilson Director 2111 North Molter Road, Liberty Lake, WA 99019
Lynda Ziegler Director 2111 North Molter Road, Liberty Lake, WA 99019
Daniel Pelino Director 2111 North Molter Road, Liberty Lake, WA 99019

President

Name Role Address
Philip Mezey President 2111 North Molter Road, Liberty Lake, WA 99019

Treasurer

Name Role Address
W. Mark Schmitz Treasurer 2111 North Molter Road, Liberty Lake, WA 99019

Vice President

Name Role Address
W. Mark Schmitz Vice President 2111 North Molter Road, Liberty Lake, WA 99019
John W Holleran Vice President 2111 North Molter Road, Liberty Lake, WA 99019

Secretary

Name Role Address
Shannon M. Votava Secretary 2111 North Molter Road, Liberty Lake, WA 99019

Filings

Type Status Filed Date Description
Withdrawal Filed 2016-04-12 Withdrawal For ITRON, INC
Annual Report Filed 2015-03-30 Annual Report For ITRON, INC
Annual Report Filed 2014-04-08 Annual Report
Annual Report Filed 2013-03-25 Annual Report
Formation Form Filed 2012-10-25 Formation
Merger Filed 2012-10-25 Merger

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339406688 0419400 2013-09-04 3010 LAKELAND COVE SUITE S, FLOWOOD, MS, 39232
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-09-05
Case Closed 2014-02-05

Related Activity

Type Complaint
Activity Nr 848387
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100022 A01
Issuance Date 2014-01-15
Abatement Due Date 2014-01-23
Current Penalty 1260.0
Initial Penalty 2100.0
Final Order 2014-01-31
Nr Instances 2
Nr Exposed 8
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: (a) Cert Department - On or about September 5, 2013 electrical cords, cables, equipment and boxes were on floors creating trip hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100303 B02
Issuance Date 2014-01-15
Abatement Due Date 2014-01-23
Current Penalty 1260.0
Initial Penalty 2100.0
Final Order 2014-01-31
Nr Instances 5
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling: (a) Cert Department - During the period July 31, 2013 through September 5, 2013 two electrical outlet boxes were in use lying on floor. The boxes were not mounted. (b) Testing - On or about September 5, 2013 three relocatable power taps (power strips/surge protectors) were used in series to power meter test stations.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2014-01-15
Abatement Due Date 2014-01-23
Current Penalty 1260.0
Initial Penalty 2100.0
Final Order 2014-01-31
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws: (a) Cert Department - On or about September 5, 2013 employee(s) were using a shop made flexible electrical power cord. No strain relief was provided at male plug attachment.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100332 B01
Issuance Date 2014-01-15
Abatement Due Date 2014-02-06
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2014-01-31
Nr Instances 4
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: (a) Cert Department - On or about September 5, 2013 employees exposed to electric shock hazard. Employees were were not trained safety-related work practices.
Citation ID 02001
Citaton Type Other
Standard Cited 19100132 D01
Issuance Date 2014-01-15
Abatement Due Date 2014-02-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-31
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): (a) Cert Department - On or about September 5, 2013 employees worked with electrical conductor and equipment. The employer has not assessed the workplace to determine the use of personal protective equipment.