Name: | Conlee Construction Services, LLC |
Jurisdiction: | MISSISSIPPI |
Business Type: | Limited Liability Company |
Status: | Good Standing |
Effective Date: | 14 Jan 2014 (11 years ago) |
Business ID: | 1034199 |
ZIP code: | 38650 |
County: | Union |
State of Incorporation: | MISSISSIPPI |
Principal Office Address: | 1557 State Road 30 W, Suite AMyrtle, MS 38650 |
Type | Company Name | Company Number | State |
---|---|---|---|
Headquarter of | Conlee Construction Services, LLC, ALABAMA | 001-089-557 | ALABAMA |
Name | Role | Address |
---|---|---|
Greg Conlee | Agent | 6 CR 281, Oxford, MS 38655 |
Name | Role | Address |
---|---|---|
Greg N Conlee | Manager | 6 CR 281, Oxford, MS 38655 |
Type | Status | Filed Date | Description |
---|---|---|---|
Annual Report LLC | Filed | 2025-01-15 | Annual Report For Conlee Construction Services, LLC |
Annual Report LLC | Filed | 2024-01-30 | Annual Report For Conlee Construction Services, LLC |
Annual Report LLC | Filed | 2023-01-20 | Annual Report For Conlee Construction Services, LLC |
Annual Report LLC | Filed | 2022-09-09 | Annual Report For Conlee Construction Services, LLC |
Amendment Form | Filed | 2022-09-09 | Amendment For Conlee Construction Services, LLC |
Notice to Dissolve/Revoke | Filed | 2022-09-05 | Notice of Intent to Dissolve: AR: Conlee Construction Services, LLC |
Annual Report LLC | Filed | 2021-09-20 | Annual Report For Conlee Construction Services, LLC |
Notice to Dissolve/Revoke | Filed | 2021-09-07 | Notice of Intent to Dissolve: AR: Conlee Construction Services, LLC |
Annual Report LLC | Filed | 2020-09-24 | Annual Report For Conlee Construction Services, LLC |
Notice to Dissolve/Revoke | Filed | 2020-08-28 | Notice to Dissolve/Revoke |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345291041 | 0419400 | 2021-05-05 | 1000 JEFFERSON AVENUE, OXFORD, MS, 38655 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1765060 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1530721 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2021-07-28 |
Current Penalty | 3400.0 |
Initial Penalty | 5461.0 |
Final Order | 2021-08-25 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (a) South Outside Form Wall - On or about May 5, 2021 the employer did not ensure that scaffolding was fully planked exposing employees to a fall hazard. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2021-07-28 |
Current Penalty | 3400.0 |
Initial Penalty | 5461.0 |
Final Order | 2021-08-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. (a) South Outside Form Wall - On or about May 5, 2021 the employer did not ensure employees were protected from falls when working above ten feet from scaffolding, exposing employees to fall hazards. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260651 I03 |
Issuance Date | 2021-07-28 |
Current Penalty | 2800.0 |
Initial Penalty | 4681.0 |
Final Order | 2021-08-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(i)(3):Sidewalks, pavements and appurtenant structure shall not be undermined unless a support system or another method of protection is provided to protect employees from the possible collapse of such structures. (a) North Jobsite - On or about May 5, 2021 the employer did not install a support system for an undermined concrete sidewalk exposing employees to a struck-by hazard. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260651 J01 |
Issuance Date | 2021-07-28 |
Current Penalty | 3400.0 |
Initial Penalty | 5461.0 |
Final Order | 2021-08-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(j)(1): Adequate protection shall be provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face. Such protection shall consist of scaling to remove loose material; installation of protective barricades at intervals as necessary on the face to stop and contain falling material; or other means that provide equivalent protection. (a) North Jobsite - On or about May 5, 2021 the employer did not install a support system for a vertical wall excavation exposing employees to a struck-by hazard. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19260701 B |
Issuance Date | 2021-07-28 |
Current Penalty | 0.0 |
Initial Penalty | 4681.0 |
Final Order | 2021-08-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement. (a) Northwest Jobsite - On or about May 5, 2021 the employer did not install protective caps over exposed rebar exposing employees to an impalement hazard. |
Date of last update: 18 Feb 2025
Sources: Mississippi Secretary of State