Name: | Myco Construction, Inc. |
Jurisdiction: | MISSISSIPPI |
Business Type: | Profit Corporation |
Status: | Dissolved |
Effective Date: | 29 Apr 2014 (11 years ago) |
Business ID: | 1040475 |
ZIP code: | 39503 |
County: | Harrison |
State of Incorporation: | MISSISSIPPI |
Principal Office Address: | 11190 LANDON LAKE BLVD, 11190 LANDON LAKE BLVDGulfport, MS 39503 |
Fictitious names: |
Myco Custom Painting & Drywall |
Name | Role | Address |
---|---|---|
Hernandez, Miguel | Agent | 11314 Riverbend Dr, Gulfport, MS 39503 |
Name | Role | Address |
---|---|---|
MIGUEL HERNANDEZ Sr | President | 11190 LANDON LAKE BLVD, GULFPORT, MS 39503 |
Name | Role | Address |
---|---|---|
MIGUEL HERNANDEZ Sr | Treasurer | 11190 LANDON LAKE BLVD, GULFPORT, MS 39503 |
Name | Role | Address |
---|---|---|
Miguel Hernandez | Incorporator | 11314 Riverbend Dr, Gulfport, MS 39503 |
Name | Role | Address |
---|---|---|
JOSEPH HERNANDEZ | Secretary | 11190 LANDON LAKE BLVD, GULFPORT, MS 39503 |
Type | Status | Filed Date | Description |
---|---|---|---|
Admin Dissolution | Filed | 2024-12-01 | Action of Intent to Dissolve: AR: Myco Construction, Inc. |
Notice to Dissolve/Revoke | Filed | 2024-09-01 | Notice of Intent to Dissolve: AR: Myco Construction, Inc. |
Annual Report | Filed | 2023-01-20 | Annual Report For Myco Construction, Inc. |
Annual Report | Filed | 2022-03-04 | Annual Report For Myco Construction, Inc. |
Annual Report | Filed | 2021-09-21 | Annual Report For Myco Construction, Inc. |
Notice to Dissolve/Revoke | Filed | 2021-09-07 | Notice of Intent to Dissolve: AR: Myco Construction, Inc. |
Fictitious Name Registration | Filed | 2020-11-10 | Fictitious Name Registration For Myco Construction, Inc. |
Annual Report | Filed | 2020-10-23 | Annual Report For Myco Construction, Inc. |
Notice to Dissolve/Revoke | Filed | 2020-08-28 | Notice to Dissolve/Revoke |
Annual Report | Filed | 2019-01-22 | Annual Report For Myco Construction, Inc. |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343028122 | 0419400 | 2018-03-19 | 521 2ND STREET, GULFPORT, MS, 39507 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
342189248 | 0419400 | 2017-03-22 | 521 2ND ST., GULFPORT, MS, 39507 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2017-06-14 |
Abatement Due Date | 2017-06-16 |
Current Penalty | 3422.0 |
Initial Penalty | 3422.0 |
Final Order | 2017-07-11 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: (a) South side of roof - On or about March 22, 2017 employees were working on top of the house attaching shingles not protected from falling with the use a fall protection system. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260502 D15 |
Issuance Date | 2017-06-14 |
Abatement Due Date | 2017-06-16 |
Current Penalty | 3422.0 |
Initial Penalty | 3422.0 |
Final Order | 2017-07-11 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person. (a) South side of roof - On or about March 22, 2017 employees attaching shingles to the roof has the vertical lifeline rope wrapped around the stack of shingles and not attached to an anchor point capable of holding 5,000 pounds. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2017-06-14 |
Abatement Due Date | 2017-06-16 |
Current Penalty | 1956.0 |
Initial Penalty | 1956.0 |
Final Order | 2017-07-11 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. (a) North side of house - On or about March 22, 2017 employees roofing the house gained access to the roof using a "little giant tri-folding ladder" that was not tall enough to extend 3 feet above the roofs edge and it was not tied off to keep it from falling. |