344385117
|
0419400
|
2019-10-17
|
101 HIGHWAY 11, POPLARVILLE, MS, 39470
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-10-17
|
Emphasis |
L: FORKLIFT, P: FORKLIFT
|
Case Closed |
2020-01-07
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260602 D |
Issuance Date |
2019-11-05 |
Abatement Due Date |
2019-12-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-12-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l): (a) Throughout the job site - On or about October 17, 2019 the employer failed to insure that the forklift operator had a current certificate of training before allowing him to operate the All-Terrain forklift exposing employees to struck by hazards. |
|
|
341359750
|
0419400
|
2016-03-28
|
WEST OF I55 ON HWY 28, HAZLEHURST, MS, 39083
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-03-28
|
Emphasis |
N: CTARGET, P: FALL, L: FALL, L: FORKLIFT
|
Case Closed |
2017-05-10
|
Related Activity
Type |
Inspection |
Activity Nr |
1135986 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 A01 |
Issuance Date |
2016-05-24 |
Abatement Due Date |
2016-05-31 |
Current Penalty |
1630.0 |
Initial Penalty |
2200.0 |
Final Order |
2016-06-08 |
Nr Instances |
10 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(a)(1): Scaffold(s) and scaffold(s) component(s) were not capable of supporting, without failure, its own weight and at least four times the maximum intended load applied or transmitted to it: (a) Emergency Room Entrance - On or about March 28, 2016 two employees were exposed to a falls from a scaffold 10 feet 4 inches above ground overloaded with bricks. Scaffold platform was sagging from the weight of the bricks. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2016-05-24 |
Abatement Due Date |
2016-05-31 |
Current Penalty |
1630.0 |
Initial Penalty |
2200.0 |
Final Order |
2016-06-08 |
Nr Instances |
10 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: (a) Emergency Room Entrance - On or about March 28, 2016 two employees were exposed to a fall hazard while working on a scaffold 10 feet 4 inches above the ground that was not mounted on base-plates. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260454 B |
Issuance Date |
2016-05-24 |
Abatement Due Date |
2016-05-31 |
Current Penalty |
1630.0 |
Initial Penalty |
2200.0 |
Final Order |
2016-06-08 |
Nr Instances |
10 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: (a) Emergency Room Entrance - On or about March 28, 2016 employees were exposed to fall hazard while working on a scaffold without training on how to recognize, prevent and eliminate fall hazards. |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19260452 C02 |
Issuance Date |
2016-05-24 |
Abatement Due Date |
2016-05-31 |
Current Penalty |
1630.0 |
Initial Penalty |
4400.0 |
Final Order |
2016-06-08 |
Nr Instances |
10 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: (a) Emergency Room Entrance - On or about March 28, 2016 employees were exposed to a fall hazard while working on a scaffold 10 feet 4 inches above the ground that was missing interior cross-braces. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19260451 F03 |
Issuance Date |
2016-05-24 |
Abatement Due Date |
2016-05-31 |
Current Penalty |
440.0 |
Initial Penalty |
440.0 |
Final Order |
2016-06-08 |
Nr Instances |
10 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) Emergency Room Entrance - On or about March 28, 2016 two employees were exposed to a fall hazard from a scaffold 10 feet 4 inches above the ground was not inspected prior to use. The scaffold was overloaded with bricks, no base-plates installed, missing interior cross-braces, not fully decked or planked and had no guardrails installed. |
|
|
313627549
|
0419400
|
2009-10-29
|
55 ARENA DRIVE, HATTIESBURG, MS, 39401
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2009-10-29
|
Emphasis |
S: COMMERCIAL CONSTR, L: FALL, S: FALL FROM HEIGHT
|
Case Closed |
2009-11-20
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2009-11-10 |
Abatement Due Date |
2009-11-19 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
04 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260501 B04 II |
Issuance Date |
2009-11-10 |
Abatement Due Date |
2009-11-16 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
01 |
|
|
304313489
|
0419400
|
2002-03-22
|
1021 POPPS FERRY ROAD, BILOXI, MS, 39530
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2002-03-22
|
Emphasis |
L: FALL, S: CONSTRUCTION
|
Case Closed |
2002-04-15
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B07 |
Issuance Date |
2002-04-01 |
Abatement Due Date |
2002-04-05 |
Current Penalty |
300.0 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2002-04-01 |
Abatement Due Date |
2002-04-05 |
Current Penalty |
400.0 |
Initial Penalty |
600.0 |
Nr Instances |
6 |
Nr Exposed |
5 |
Gravity |
02 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 I |
Issuance Date |
2002-04-01 |
Abatement Due Date |
2002-04-05 |
Current Penalty |
700.0 |
Initial Penalty |
1050.0 |
Nr Instances |
4 |
Nr Exposed |
5 |
Gravity |
05 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 II |
Issuance Date |
2002-04-01 |
Abatement Due Date |
2002-04-05 |
Current Penalty |
700.0 |
Initial Penalty |
1050.0 |
Nr Instances |
6 |
Nr Exposed |
5 |
Gravity |
05 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260451 F04 |
Issuance Date |
2002-04-01 |
Abatement Due Date |
2002-04-05 |
Current Penalty |
700.0 |
Initial Penalty |
1050.0 |
Nr Instances |
8 |
Nr Exposed |
5 |
Gravity |
05 |
|
|