Search icon

SMITH MASONRY LLC

Company Details

Name: SMITH MASONRY LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Good Standing
Effective Date: 20 May 2015 (10 years ago)
Business ID: 1067879
ZIP code: 39475
County: Lamar
State of Incorporation: MISSISSIPPI
Principal Office Address: 314 MAX WHITE RDPURVIS, MS 39475

Agent

Name Role Address
LINDA S SMITH Agent 314 MAX WHITE RD, PURVIS, MS 39475

Member

Name Role Address
RUSTY B SMITH Member 314 MAX WHITE RD, PURVIS, MS 39475
LINDA S SMITH Member 314 MAX WHITE RD, PURVIS, MS 39475

Filings

Type Status Filed Date Description
Annual Report LLC Filed 2025-03-02 Annual Report For SMITH MASONRY LLC
Registered Agent Change of Address Filed 2024-11-08 Agent Address Change For LINDA S SMITH
Annual Report LLC Filed 2024-02-26 Annual Report For SMITH MASONRY LLC
Annual Report LLC Filed 2023-02-16 Annual Report For SMITH MASONRY LLC
Annual Report LLC Filed 2022-03-10 Annual Report For SMITH MASONRY LLC
Annual Report LLC Filed 2021-02-18 Annual Report For SMITH MASONRY LLC
Annual Report LLC Filed 2020-02-20 Annual Report For SMITH MASONRY LLC
Annual Report LLC Filed 2019-02-16 Annual Report For SMITH MASONRY LLC
Annual Report LLC Filed 2018-02-13 Annual Report For SMITH MASONRY LLC
Annual Report LLC Filed 2017-02-02 Annual Report For SMITH MASONRY LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344385117 0419400 2019-10-17 101 HIGHWAY 11, POPLARVILLE, MS, 39470
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-10-17
Emphasis L: FORKLIFT, P: FORKLIFT
Case Closed 2020-01-07

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260602 D
Issuance Date 2019-11-05
Abatement Due Date 2019-12-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-12-05
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l): (a) Throughout the job site - On or about October 17, 2019 the employer failed to insure that the forklift operator had a current certificate of training before allowing him to operate the All-Terrain forklift exposing employees to struck by hazards.
341359750 0419400 2016-03-28 WEST OF I55 ON HWY 28, HAZLEHURST, MS, 39083
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-03-28
Emphasis N: CTARGET, P: FALL, L: FALL, L: FORKLIFT
Case Closed 2017-05-10

Related Activity

Type Inspection
Activity Nr 1135986
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 A01
Issuance Date 2016-05-24
Abatement Due Date 2016-05-31
Current Penalty 1630.0
Initial Penalty 2200.0
Final Order 2016-06-08
Nr Instances 10
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(1): Scaffold(s) and scaffold(s) component(s) were not capable of supporting, without failure, its own weight and at least four times the maximum intended load applied or transmitted to it: (a) Emergency Room Entrance - On or about March 28, 2016 two employees were exposed to a falls from a scaffold 10 feet 4 inches above ground overloaded with bricks. Scaffold platform was sagging from the weight of the bricks.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2016-05-24
Abatement Due Date 2016-05-31
Current Penalty 1630.0
Initial Penalty 2200.0
Final Order 2016-06-08
Nr Instances 10
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: (a) Emergency Room Entrance - On or about March 28, 2016 two employees were exposed to a fall hazard while working on a scaffold 10 feet 4 inches above the ground that was not mounted on base-plates.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2016-05-24
Abatement Due Date 2016-05-31
Current Penalty 1630.0
Initial Penalty 2200.0
Final Order 2016-06-08
Nr Instances 10
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: (a) Emergency Room Entrance - On or about March 28, 2016 employees were exposed to fall hazard while working on a scaffold without training on how to recognize, prevent and eliminate fall hazards.
Citation ID 02001
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2016-05-24
Abatement Due Date 2016-05-31
Current Penalty 1630.0
Initial Penalty 4400.0
Final Order 2016-06-08
Nr Instances 10
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: (a) Emergency Room Entrance - On or about March 28, 2016 employees were exposed to a fall hazard while working on a scaffold 10 feet 4 inches above the ground that was missing interior cross-braces.
Citation ID 03001
Citaton Type Other
Standard Cited 19260451 F03
Issuance Date 2016-05-24
Abatement Due Date 2016-05-31
Current Penalty 440.0
Initial Penalty 440.0
Final Order 2016-06-08
Nr Instances 10
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) Emergency Room Entrance - On or about March 28, 2016 two employees were exposed to a fall hazard from a scaffold 10 feet 4 inches above the ground was not inspected prior to use. The scaffold was overloaded with bricks, no base-plates installed, missing interior cross-braces, not fully decked or planked and had no guardrails installed.
313627549 0419400 2009-10-29 55 ARENA DRIVE, HATTIESBURG, MS, 39401
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2009-10-29
Emphasis S: COMMERCIAL CONSTR, L: FALL, S: FALL FROM HEIGHT
Case Closed 2009-11-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2009-11-10
Abatement Due Date 2009-11-19
Current Penalty 1000.0
Initial Penalty 1000.0
Nr Instances 1
Nr Exposed 2
Gravity 04
Citation ID 02001
Citaton Type Other
Standard Cited 19260501 B04 II
Issuance Date 2009-11-10
Abatement Due Date 2009-11-16
Nr Instances 2
Nr Exposed 2
Gravity 01
304313489 0419400 2002-03-22 1021 POPPS FERRY ROAD, BILOXI, MS, 39530
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2002-03-22
Emphasis L: FALL, S: CONSTRUCTION
Case Closed 2002-04-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B07
Issuance Date 2002-04-01
Abatement Due Date 2002-04-05
Current Penalty 300.0
Initial Penalty 450.0
Nr Instances 1
Nr Exposed 5
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2002-04-01
Abatement Due Date 2002-04-05
Current Penalty 400.0
Initial Penalty 600.0
Nr Instances 6
Nr Exposed 5
Gravity 02
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2002-04-01
Abatement Due Date 2002-04-05
Current Penalty 700.0
Initial Penalty 1050.0
Nr Instances 4
Nr Exposed 5
Gravity 05
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2002-04-01
Abatement Due Date 2002-04-05
Current Penalty 700.0
Initial Penalty 1050.0
Nr Instances 6
Nr Exposed 5
Gravity 05
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 F04
Issuance Date 2002-04-01
Abatement Due Date 2002-04-05
Current Penalty 700.0
Initial Penalty 1050.0
Nr Instances 8
Nr Exposed 5
Gravity 05