Search icon

AZZ Galvanizing - Kosciusko, LLC

Company Details

Name: AZZ Galvanizing - Kosciusko, LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Withdrawn
Effective Date: 11 Jun 2015 (10 years ago)
Business ID: 1069265
State of Incorporation: DELAWARE
Principal Office Address: 3100 W. 7th Street, Suite 500Fort Worth, TX 76107
Historical names: AZZ Galvanizing - Kosciusko

Agent

Name Role Address
C. T. CORPORATION SYSTEM Agent 645 LAKELAND DRIVE EAST DR., STE 101, FLOWOOD, MS 39232

Member

Name Role Address
AZZ Acquisition Sub, LLC Member 3100 W. 7th Street, Suite 500, Fort Worth, TX 76107

Filings

Type Status Filed Date Description
Withdrawal Filed 2017-09-15 Withdrawal For AZZ Galvanizing - Kosciusko, LLC
Annual Report LLC Filed 2017-03-21 Annual Report For AZZ Galvanizing - Kosciusko, LLC
Annual Report LLC Filed 2016-03-30 Annual Report For AZZ Galvanizing - Kosciusko, LLC
Fictitious Name Registration Filed 2016-02-05 Fictitious Name Registration For AZZ Galvanizing - Kosciusko, LLC
Formation Form Filed 2015-06-11 Formation For AZZ Galvanizing - Kosciusko, LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341428084 0419400 2016-04-27 2235 ATTALA ROAD 2202, KOSCIUSKO, MS, 39090
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2016-05-05
Case Closed 2016-08-26

Related Activity

Type Complaint
Activity Nr 1084503
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2016-08-01
Abatement Due Date 2016-09-14
Current Penalty 5000.0
Initial Penalty 5500.0
Final Order 2016-08-17
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): Public Law 91-596, the Occupational Safety and Health Act of 1970, Section 5(a)(1): The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or are likely to cause death or serious physical harm to his employees, in that employees were exposed to: Structural steel components were not designed to tolerate corrosion and were not protected against corrosion that impairs the strength or serviceability of the structure according to the American Institute of Steel Construction, Inc. Manual of Steel Construction ninth edition. (a) 2235 Attala Road 2202 in Kosciusko, MS - On or about April 27 to May 5, 2016, there were two columns on the South end of dip tanks of hydrochloric acid solutions that were corroded to the center core of the flanges on the steel I-beams.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100022 B01
Issuance Date 2016-08-01
Abatement Due Date 2016-08-23
Current Penalty 5000.0
Initial Penalty 7000.0
Final Order 2016-08-17
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. (a) 2235 Attala Road 2202 in Kosciusko, MS - On or about April 27 to May 5, 2016, the two walkways (catwalks) between the acid tanks were not kept in good repair. The legs supporting the walkways were damaged and corroded to the point that some were bent, broken, and/or missing.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100023 C03
Issuance Date 2016-08-01
Abatement Due Date 2016-08-23
Current Penalty 5000.0
Initial Penalty 5500.0
Final Order 2016-08-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board. (a) 2235 Attala Road 2202 in Kosciusko, MS - On or about April 27 to May 5, 2016, employees were not protected from falling into the hydrochloric acid solutions used to clean the steel because top guard rails were bent down or missing along the catwalks between the acid tanks and guard rails were missing on the ends of the acid tanks where employees walk from one tank to another.
Citation ID 01004
Citaton Type Other
Standard Cited 19100179 E02 I
Issuance Date 2016-08-01
Abatement Due Date 2016-08-16
Current Penalty 3000.0
Initial Penalty 4400.0
Final Order 2016-08-17
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.179(e)(2)(i): Crane(s) were not provided with bridge bumpers or other automatic means providing equivalent effect: (a) 2235 Attala Road 2202 in Kosciusko, MS - On or about April 27 to May 5, 2016, three of the four bumper were missing on the 10 ton crane in use at the facility. A wood board was attached with wire for one of the four missing bumpers.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100179 L03 I
Issuance Date 2016-08-01
Abatement Due Date 2016-08-16
Current Penalty 0.0
Initial Penalty 5500.0
Final Order 2016-08-17
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.179(l)(3)(i): Unsafe condition(s) disclosed during the frequent or periodic inspection(s) required by 29 CFR 1910.179(j) were not corrected before operation of the crane(s) was resumed: (a) 2235 Attala Road 2202 in Kosciusko, MS - On or about April 27 to May 5, 2016, the motor on the North end of the bridge was not bolted on as required. It had heavy metal wire wrapped around the motor.

Date of last update: 29 Mar 2025