Search icon

SmartStop Self Storage, Inc.

Company Details

Name: SmartStop Self Storage, Inc.
Jurisdiction: MISSISSIPPI
Business Type: Profit Corporation
Status: Revoked
Effective Date: 21 Sep 2015 (10 years ago)
Business ID: 1076166
State of Incorporation: MARYLAND
Principal Office Address: 111 Corporate Drive, Suite 120Ladera Ranch, CA 92694

President

Name Role Address
H. Michael Schwartz President 111 Corporate Drive, Suite 120, Ladera Ranch, CA 92694

Agent

Name Role Address
C. T. CORPORATION SYSTEM Agent 645 LAKELAND DRIVE EAST DR., STE 101, FLOWOOD, MS 39232

Filings

Type Status Filed Date Description
Admin Dissolution Filed 2016-11-30 Admin Dissolution
Notice to Dissolve/Revoke Filed 2016-09-06 Notice to Dissolve/Revoke
Formation Form Filed 2015-09-21 Formation For SmartStop Self Storage, Inc.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339029019 0419400 2013-04-25 426 CHRISTINE DRIVE, RIDGELAND, MS, 39157
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-04-26
Emphasis L: FALL
Case Closed 2013-06-20

Related Activity

Type Complaint
Activity Nr 814972
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2013-05-10
Abatement Due Date 2013-05-24
Current Penalty 2160.0
Initial Penalty 3600.0
Final Order 2013-05-31
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees exposed to a fall hazard: (a) On Site Property Manager's Apartment - On or about April 26, 2013, an employee was exposed to a fall hazard when using the top step of a 8 foot fiberglass step ladder to access the top of apartment in order to empty containers filled with rain water.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100023 C01
Issuance Date 2013-05-10
Abatement Due Date 2013-05-24
Current Penalty 2160.0
Initial Penalty 3600.0
Final Order 2013-05-31
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. (a) Upstairs Self Storage Units - On or about April 26, 2013, an employee was exposed to a 10 feet fall hazard when changing out fluorescent light bulbs from the top storage units lacking standard railings or fall arrest systems.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100303 F
Issuance Date 2013-05-10
Abatement Due Date 2013-05-24
Current Penalty 1620.0
Initial Penalty 2700.0
Final Order 2013-05-31
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(f): Each service, feeder and branch circuit, at its disconnecting means or over current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Maintenance Storage Room - On or about April 25, 2013 the breakers in the electrical panel box were not labeled.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100303 G02 I
Issuance Date 2013-05-10
Abatement Due Date 2013-05-22
Current Penalty 2700.0
Initial Penalty 4500.0
Final Order 2013-05-31
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): (a) Maintenance Storage Room - On or about April 25, 2013, live parts located in the main power box were not guarded against accidential contact in that the front covers were missing.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100332 B02
Issuance Date 2013-05-10
Abatement Due Date 2013-05-24
Current Penalty 3780.0
Initial Penalty 6300.0
Final Order 2013-05-31
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.332(b)(2): Employees, who were not qualified persons, were not trained in and familiar with any electrically related safety practices not specifically addressed by 29 CFR 1910.331 through 29 CFR 1910.335, but which were necessary for their safety. (a) Self Storage Area - On or about April 25, 2013 unqualified employee has had little to know training on the removal and installation of ballast.