Search icon

JONES LUMBER NATCHEZ, LLC

Company Details

Name: JONES LUMBER NATCHEZ, LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Good Standing
Effective Date: 06 Oct 2015 (9 years ago)
Business ID: 1077240
ZIP code: 39402
County: Lamar
State of Incorporation: MISSISSIPPI
Principal Office Address: 16 Office Park Drive, Suite 10Hattiesburg, MS 39402
Historical names: JONES LUMBER GLOSTER, LLC

Agent

Name Role Address
Capitol Corporate Services, Inc. Agent 248 E Capitol St., Ste 840, Jackson, MS 39201

Organizer

Name Role Address
Joseph M Stinson Organizer P O Drawer 408, 1108 Beulah Avenue, Tylertown, MS 39667

Manager

Name Role Address
JJ Management, LLC Manager 16 Office Park Drive Ste 10, Hattiesburg, MS 39402

Filings

Type Status Filed Date Description
Annual Report LLC Filed 2024-04-15 Annual Report For JONES LUMBER NATCHEZ, LLC
Annual Report LLC Filed 2023-01-31 Annual Report For JONES LUMBER NATCHEZ, LLC
Amendment Form Filed 2022-10-20 Amendment For JONES LUMBER GLOSTER, LLC
Amendment Form Filed 2022-10-05 Amendment For JONES LUMBER GLOSTER, LLC
Annual Report LLC Filed 2022-02-21 Annual Report For JONES LUMBER GLOSTER, LLC
Annual Report LLC Filed 2021-03-16 Annual Report For JONES LUMBER GLOSTER, LLC
Annual Report LLC Filed 2020-03-09 Annual Report For JONES LUMBER GLOSTER, LLC
Amendment Form Filed 2020-02-12 Amendment For JONES LUMBER GLOSTER, LLC
Annual Report LLC Filed 2019-01-11 Annual Report For JONES LUMBER GLOSTER, LLC
Annual Report LLC Filed 2018-02-23 Annual Report For JONES LUMBER GLOSTER, LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341870376 0419400 2016-10-26 2485 HIGHWAY 24, GLOSTER, MS, 39638
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2016-10-27
Emphasis L: LEAD, N: LEAD
Case Closed 2017-03-29

Related Activity

Type Referral
Activity Nr 1148832
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2017-02-23
Abatement Due Date 2017-02-27
Current Penalty 4563.0
Initial Penalty 7605.0
Final Order 2017-03-27
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. (a) On or about October 26, 2016 the rotating knife sharpener was not equipped with a guard to protect employees wearing loose clothing that could resulting into struck-by hazards.
341851657 0419400 2016-10-18 2485 HIGHWAY 24 31.19105614; -90.9557002, GLOSTER, MS, 39638
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2016-10-19
Emphasis L: FORKLIFT, L: LEAD, N: AMPUTATE, N: LEAD
Case Closed 2017-01-23

Related Activity

Type Referral
Activity Nr 1145580
Safety Yes
Type Inspection
Activity Nr 1186799
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 D04 I
Issuance Date 2016-12-20
Abatement Due Date 2017-01-12
Current Penalty 7482.6
Initial Penalty 12471.0
Final Order 2017-01-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) At the oversize conveyor - On or about October 12, 2016, there was no lockout/tagout device affixed to the control for the oversize conveyor.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100303 B02
Issuance Date 2016-12-20
Abatement Due Date 2017-01-05
Current Penalty 4275.6
Initial Penalty 7126.0
Final Order 2017-01-16
Nr Instances 1
Nr Exposed 34
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) In the break room - On or about Oct 25, 2016, two re-locatable power taps (RLPT) on the left side entering the break room were daisy chained together. A third RLPT was plugged into an extension cord reel.
Citation ID 02001
Citaton Type Other
Standard Cited 19100132 D02
Issuance Date 2016-12-20
Abatement Due Date 2017-01-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-01-16
Nr Instances 1
Nr Exposed 34
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: (a) At the facility - On or about October 19, 2016, the employer did not have the required hazard assessment for the workplace, there was no person certifying that the evaluation had been performed.
Citation ID 02002
Citaton Type Other
Standard Cited 19100265 D02 I D
Issuance Date 2016-12-20
Abatement Due Date 2016-12-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-01-16
Nr Instances 1
Nr Exposed 34
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.265(d)(2)(i)(d): Sign(s) were not posted prohibiting unauthorized foot or vehicle traffic in log unloading and storage area(s): (a) Log storage and handling yard - On or about October 19, 2016, there was no signs posted prohibiting unauthorized foot or vehicle traffic in the yard.
341581338 0419400 2016-06-20 2485 HIGHWAY 24 N 31.19110; -90.95566 W, GLOSTER, MS, 39638
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2016-06-23
Emphasis L: FORKLIFT, N: AMPUTATE
Case Closed 2017-01-18

Related Activity

Type Referral
Activity Nr 1102499
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2016-12-20
Abatement Due Date 2017-01-12
Current Penalty 7482.6
Initial Penalty 12471.0
Final Order 2017-01-17
Nr Instances 1
Nr Exposed 26
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Old Saw Mill, Throughout - On or about June 20, 2016 no energy control program, including machine-specific procedures, had been fully developed or implemented to protect employees from electrical shock or unexpected start-up while performing maintenance on the following: the Head (rig) Saw, the Log Carriage, the Edger, the two Chippers, the Trim Saws, the Roller Bed, the Lumber Conveying Chains, the Shaker Screen, the Vibrators, etc.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100265 C05 II
Issuance Date 2016-12-20
Abatement Due Date 2017-01-12
Current Penalty 3634.2
Initial Penalty 6057.0
Final Order 2017-01-17
Nr Instances 1
Nr Exposed 26
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.265(c)(5)(ii): Stairways were not provided with a standard handrail on at least one side or on any open side: (a) Old Saw Mill; West of Scale House-Office, at North end of Employee Break Room - There were no standard handrails on either side of the 47 inch wide by 27 inch high by 4 risers high concrete steps leading to and from the north end of the Employee Break Room.
Citation ID 02001
Citaton Type Other
Standard Cited 19100022 B01
Issuance Date 2016-12-20
Abatement Due Date 2017-01-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-01-17
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(b)(1): 29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. (a) Scale House - Office, on floor between Office Manager's Desk and the Hewlett-Packard Printer-Scanner - On or about June 21, 2016 employees were exposed to a tripping hazard due to an unprotected round black cord running along the floor.

Date of last update: 20 Feb 2025