Name: | Old Byram Masonry of Mississippi, LLC |
Jurisdiction: | MISSISSIPPI |
Business Type: | Limited Liability Company |
Status: | Dissolved |
Effective Date: | 02 Mar 2016 (9 years ago) |
Business ID: | 1087172 |
ZIP code: | 39170 |
County: | Hinds |
State of Incorporation: | MISSISSIPPI |
Principal Office Address: | 4799 Old Jackson RdTerry, MS 39170 |
Name | Role | Address |
---|---|---|
McGee Tax Law, PLLC | Agent | 125 S. Congress St. Suite 1240, Jackson, MS 39201 |
Name | Role | Address |
---|---|---|
Chad Griggs | Member | 4799 Old Jackson Road, Terry, MS 39170 |
Type | Status | Filed Date | Description |
---|---|---|---|
Admin Dissolution | Filed | 2019-11-22 | Admin Dissolution: AR |
Notice to Dissolve/Revoke | Filed | 2019-08-22 | Notice to Dissolve/Revoke |
Annual Report LLC | Filed | 2018-05-07 | Annual Report For Old Byram Masonry of Mississippi, LLC |
Annual Report LLC | Filed | 2017-01-23 | Annual Report For Old Byram Masonry of Mississippi, LLC |
Annual Report LLC | Filed | 2016-04-06 | Annual Report For Old Byram Masonry of Mississippi, LLC |
Formation Form | Filed | 2016-03-02 | Formation For Old Byram Masonry of Mississippi, LLC |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341935195 | 0419400 | 2016-11-28 | 1724 OLD FANNIN RD, FLOWOOD, MS, 39232 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2017-04-26 |
Current Penalty | 4183.0 |
Initial Penalty | 4183.0 |
Final Order | 2017-06-28 |
Nr Instances | 12 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (a) Front of the building - On or about November 28, 2016 employees were exposed to a fall hazard while working on a scaffold 13 feet 1 inch above concrete that was not fully decked or planked. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2017-04-26 |
Current Penalty | 4183.0 |
Initial Penalty | 4183.0 |
Final Order | 2017-06-28 |
Nr Instances | 3 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers: (a) Front of the building - On or about November 28, 2016 employees were exposed to a fall hazard while working on a scaffold 13 feet 1 inch above concrete with no guardrails installed. |
Citation ID | 02001 |
Citaton Type | Repeat |
Standard Cited | 19260451 E01 |
Issuance Date | 2017-04-26 |
Current Penalty | 8366.0 |
Initial Penalty | 8366.0 |
Final Order | 2017-06-28 |
Nr Instances | 4 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. (a) Front of the building - On or about November 28, 2016 employees were exposed to a fall hazard while working on a scaffold 13 feet 1 inch above concrete with a ladder that did reach the top platform. The ladder did not reach the 2nd level of the scaffold. Employees were forced to climb the frame and cross-braces to reach the top platform. OLD BYRAM MASONERY, LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.451(E)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1143034 CITATION NUMBER 1, ITEM NUMBER 1, ISSUED ON JULY 6, 2016 WITH A FINAL ORDER DATE OF SEPTEMBER 13, 2016 WITH RESPECT TO A WORKPLACE LOCATED AT 5657 HWY 25, FLOWOOD, MS 29232. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2016-04-22 |
Emphasis | L: FALL, L: FORKLIFT, P: FALL |
Case Closed | 2019-11-26 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2016-07-06 |
Abatement Due Date | 2016-07-12 |
Current Penalty | 2520.0 |
Initial Penalty | 2520.0 |
Final Order | 2016-09-14 |
Nr Instances | 4 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as used as a means of access. (a) Front of the building - On or about April 22, 2016 employees were exposed to a fall hazard while working on a scaffold 13.8 feet above the ground with a ladder that did reach the top platform. The ladder was 12.2 feet long and only reached the 2nd level of the scaffold. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G04 I |
Issuance Date | 2016-07-06 |
Abatement Due Date | 2016-07-12 |
Current Penalty | 2520.0 |
Initial Penalty | 2520.0 |
Final Order | 2016-09-14 |
Nr Instances | 4 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. (a) Front of the building - On or about April 22, 2016 employees were exposed to a fall hazard while working on a scaffold 13.8 feet above the ground with incomplete guardrails installed. The guardrails were missing in several sections of the scaffold. |
Date of last update: 30 Mar 2025