Search icon

Webster Industries, Inc.

Company Details

Name: Webster Industries, Inc.
Jurisdiction: MISSISSIPPI
Business Type: Profit Corporation
Status: Good Standing
Effective Date: 19 Sep 2016 (9 years ago)
Business ID: 1101495
State of Incorporation: OHIO
Principal Office Address: 325 Hall StreetTiffin, OH 44883

Agent

Name Role Address
CORPORATION SERVICE COMPANY Agent 109 Executive Drive, Suite 3, Madison, MS 39110

Treasurer

Name Role Address
Steven Hickey Treasurer 325 Hall St, Tiffin, OH 44883

Chief Financial Officer

Name Role Address
Steven Hickey Chief Financial Officer 325 Hall St, Tiffin, OH 44883

Secretary

Name Role Address
Brent Howard Secretary 84-88 S. Washington St, P.O. Box 767, Tiffin, OH 44883

Director

Name Role Address
Andrew Felter Director 325 Hall St., Tiffin, OH 44883

President

Name Role Address
Andrew Felter President 325 Hall St., Tiffin, OH 44883

Chief Executive Officer

Name Role Address
Andrew Felter Chief Executive Officer 325 Hall St., Tiffin, OH 44883

Filings

Type Status Filed Date Description
Annual Report Filed 2025-03-26 Annual Report For Webster Industries, Inc.
Annual Report Filed 2024-07-08 Annual Report For Webster Industries, Inc.
Annual Report Filed 2023-04-15 Annual Report For Webster Industries, Inc.
Annual Report Filed 2022-05-24 Annual Report For Webster Industries, Inc.
Registered Agent Change of Address Filed 2022-03-31 Agent Address Change For CORPORATION SERVICE COMPANY
Annual Report Filed 2021-04-12 Annual Report For Webster Industries, Inc.
Annual Report Filed 2020-04-10 Annual Report For Webster Industries, Inc.
Annual Report Filed 2019-03-26 Annual Report For Webster Industries, Inc.
Amendment Form Filed 2018-07-16 Amendment For Webster Industries, Inc.
Annual Report Filed 2018-03-27 Annual Report For Webster Industries, Inc.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340794809 0419400 2015-07-22 3800 2ND STREET, MERIDIAN, MS, 39301
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2015-07-22
Emphasis N: PMETALS
Case Closed 2015-07-30

Related Activity

Type Inspection
Activity Nr 1045617
Health Yes
340456177 0419400 2015-03-10 3800 2ND STREET, MERIDIAN, MS, 39301
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2015-03-11
Emphasis N: PMETALS, P: PMETALS
Case Closed 2015-06-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100023 C01
Issuance Date 2015-06-02
Current Penalty 2040.0
Initial Penalty 3400.0
Final Order 2015-06-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: (a) Storage Above Office - On or about March 10, 2015, the open sided floor above the office was not guarded by standard guard rails.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100253 B02 II
Issuance Date 2015-06-02
Current Penalty 2040.0
Initial Penalty 3400.0
Final Order 2015-06-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: (a) Rear of Plant - On or about March 10, 2015 oxygen, acetylene and other LP gas cylinders were not secured to prevent them from being knock over.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100253 B04 III
Issuance Date 2015-06-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-16
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: (a) Rear of the Plant - Oxygen and Acetylene was stored together.
Citation ID 02001
Citaton Type Other
Standard Cited 19040029 A
Issuance Date 2015-06-02
Abatement Due Date 2015-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-16
Nr Instances 1
Nr Exposed 18
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent. (a) Meridian Location - On or about March 10, 2015 the employer was not maintaining the OSHA 300 - A for the previous years of 2012, 2013 and 2014. Abatement Certification and Documentation is required
Citation ID 02002
Citaton Type Other
Standard Cited 19100303 G01 III
Issuance Date 2015-06-02
Abatement Due Date 2015-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-16
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1)(iii): The employer did not ensure that at least one entrance of sufficient area was provided to give access to the working space about electric equipment 600 Volts, nominal, or less. (a) Maintenance Shop - On or about March 10, 2015, the Ingersoll Rand Air Compressor and the dryer were located in a manner that blocked access to the electrical breaker box.
Citation ID 02003A
Citaton Type Other
Standard Cited 19101200 F05 I
Issuance Date 2015-06-02
Abatement Due Date 2015-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-16
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: (a)Welding Operation - On or about March 11, 2015 the garden sprayer containing mineral spirit was not labeled with the identity of the product contained therein.
Citation ID 02003B
Citaton Type Other
Standard Cited 19101200 F05 II
Issuance Date 2015-06-02
Abatement Due Date 2015-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-16
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: (a)Welding Area - on or about March 11, 2015 the employer had not labeled the garden sprayer containing mineral spirits with the appropriate hazard warning.

Date of last update: 30 Mar 2025