Search icon

139 McDonnell LLC

Company Details

Name: 139 McDonnell LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Good Standing
Effective Date: 16 Feb 2017 (8 years ago)
Business ID: 1111825
ZIP code: 39576
County: Hancock
State of Incorporation: MISSISSIPPI
Principal Office Address: 304 highway 90 , Unit BWaveland, MS 39576
Historical names: Beach Club Apts

Agent

Name Role Address
Rujian Zhang Agent 304 highway 90, Suite B, Waveland, MS 39576

Manager

Name Role Address
Rujian Zhang Manager 133 Briarfield Avenue, Unit A23, Biloxi, MS 39531
FRANK ZHANG Manager 304 Highway 90, Unit B, Waveland, MS 39576

Filings

Type Status Filed Date Description
Annual Report LLC Filed 2025-01-22 Annual Report For 139 McDonnell LLC
Annual Report LLC Filed 2024-03-14 Annual Report For 139 McDonnell LLC
Annual Report LLC Filed 2023-04-16 Annual Report For 139 McDonnell LLC
Fictitious Name Renewal Filed 2022-10-04 Fictitious Name Renewal For 139 McDonnell LLC
Annual Report LLC Filed 2022-04-10 Annual Report For 139 McDonnell LLC
Annual Report LLC Filed 2021-04-14 Annual Report For 139 McDonnell LLC
Annual Report LLC Filed 2020-01-25 Annual Report For 139 McDonnell LLC
Annual Report LLC Filed 2019-03-13 Annual Report For 139 McDonnell LLC
Annual Report LLC Filed 2018-04-04 Annual Report For 139 McDonnell LLC
Fictitious Name Registration Filed 2017-03-14 Fictitious Name Registration For 139 McDonnell LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342642014 0419400 2017-09-15 139 MC DONNELL ST., BILOXI, MS, 39531
Inspection Type Planned
Scope NoInspection
Safety/Health Safety
Close Conference 2017-09-15
Emphasis L: FALL, P: FALL
Case Closed 2017-10-27

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260416 A03
Issuance Date 2017-10-02
Abatement Due Date 2017-10-04
Current Penalty 0.0
Initial Penalty 3803.0
Final Order 2017-10-27
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into pysical or electrical contact with the electric power circuit. (a) Outside edge of roof around building - On or about September 15, 2017 employees repairing roof of 2 story apartment building were working around the energized 3 phase 120volt main building electrical supply lines that were not marked or protected to prevent accidental contact by employees.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260453 B02 IV
Issuance Date 2017-10-02
Abatement Due Date 2017-10-04
Current Penalty 0.0
Initial Penalty 3803.0
Final Order 2017-10-27
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: (a) South side of building - On or about September 15, 2017 employee working from elevated aerial basket was standing on the mid rail with one leg and the other leg on the roofs edge repairing damaged roof material.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2017-10-02
Abatement Due Date 2017-10-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-10-27
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: (a) South side of building - On or about September 15, 2017 employee operating Genie aerial lift 17 feet high with no fall protection to prevent employee from being ejected out of basket.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2017-10-02
Abatement Due Date 2017-10-04
Current Penalty 0.0
Initial Penalty 3803.0
Final Order 2017-10-27
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. (a) Along the entire roof perimeter - On or about September 15, 2017 employees working from 2 story apartment building repairing damaged roof with no type of fall protection to prevent them from falling off the roof.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2017-10-02
Abatement Due Date 2017-10-04
Current Penalty 0.0
Initial Penalty 3803.0
Final Order 2017-10-27
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) South East side of building - On or about September 15, 2017 employees repairing roof gained access to the roof using an aluminum extension ladder that did go 3 feet past the edge of the roof.

Date of last update: 31 Mar 2025