344449236
|
0419400
|
2019-11-08
|
781 COUNTY ROAD 549, RIPLEY, MS, 38663
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-11-08
|
Case Closed |
2019-11-11
|
Related Activity
Type |
Inspection |
Activity Nr |
1398061 |
Safety |
Yes |
|
|
343980611
|
0419400
|
2019-04-30
|
781 COUNTY ROAD 549, RIPLEY, MS, 38663
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-05-01
|
Emphasis |
N: AMPUTATE, L: FORKLIFT
|
Case Closed |
2020-07-16
|
Related Activity
Type |
Complaint |
Activity Nr |
1449459 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2019-06-20 |
Abatement Due Date |
2019-08-05 |
Current Penalty |
9900.0 |
Initial Penalty |
13260.0 |
Final Order |
2019-07-16 |
Nr Instances |
3 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Optimizer 1 - On or about April 30, 2019 the employer did not provide adequate guarding for the saw blade on the Optimizer, exposing employees to amputation hazards. (b) Optimizer 2 - On or about April 30, 2019 the employer did not provide adequate guarding for the saw blade on the Optimizer, exposing employees to amputation hazards. (c) Optimizer 3 - On or about April 30, 2019 the employer did not provide adequate guarding for the saw blade on the Optimizer, exposing employees to amputation hazards. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100219 C02 I |
Issuance Date |
2019-06-20 |
Abatement Due Date |
2019-08-05 |
Current Penalty |
9472.0 |
Initial Penalty |
9472.0 |
Final Order |
2019-07-16 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) Vacuum pumps outside main building - On or about April 30, 2019, the employer did not provide adequate guarding for the rotating drive shafts of two vacuum pumps were not guarded. Employees that clean and provide maintenance are exposed to being caught-in the unguarded rotating drive shafts. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100219 C04 I |
Issuance Date |
2019-06-20 |
Abatement Due Date |
2019-08-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-07-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft. (a) Planer/Rip Facility - On or about April 30, 2019, The employer did not ensure that a rotating shaft end at the end of transfer conveyor was adequately guarded, exposing employees to a caught-in hazard. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2019-06-20 |
Abatement Due Date |
2019-08-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-07-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: (a) Planer/Rip Facility - On or about April 30, 2019 the employer did not ensure the drive chain and sprocket was adequately guarded at the end of transfer conveyor, exposing employees to a caught-in hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100252 B02 III |
Issuance Date |
2019-06-20 |
Abatement Due Date |
2019-07-22 |
Current Penalty |
0.0 |
Initial Penalty |
5683.0 |
Final Order |
2019-07-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields or required to wear protective goggles. (a) Facility - On or about April 30, 2019, the employer did not provide adequate protection for employees working near arc welding rays, exposing employees to eye hazards. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2019-06-20 |
Abatement Due Date |
2019-08-05 |
Current Penalty |
9472.0 |
Initial Penalty |
9472.0 |
Final Order |
2019-07-16 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Planer/Rip Saw Building. North and West Wall - On or about April 30, 2019 the employer did not ensure that electrical disconnects were adequately marked to indicate their purpose preventing employees from correctly identifying the electrical disconnects that controlled the equipment, exposing employees to fire hazards and amputation. (b) Main Production Building. South Wall - On or about April 30, 2019 the employer did not ensure that electrical disconnects were adequately marked to indicate their purpose preventing employees from correctly identifying the electrical disconnects that controlled the equipment, exposing employees to fire hazards and amputation. |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2019-06-20 |
Abatement Due Date |
2019-07-22 |
Current Penalty |
6250.0 |
Initial Penalty |
47360.0 |
Final Order |
2019-07-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition. (a) Planer/Rip Facility North Wall - On or about April 30, 2019 the employer did not ensure aisles and passageway to critical equipment disconnects were kept clean and passable exposing employees to trip hazards when attempting to access the electrical panels for performing energy control procedures. Industrial Timber, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.22(a)(1)), which was contained in OSHA inspection number 1162197, citation number 01, item number 001 and was affirmed as a final order on September 07, 2016, with respect to a workplace located at 781 CR 549 in Ripley, MS 38663. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 II |
Issuance Date |
2019-06-20 |
Abatement Due Date |
2019-07-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-07-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed (a) Main Building South Wall - On or about April 30, 2019, the employer did not ensure openings in the top of a 240 volt control panel were closed in a heavy wood dust environment, exposing employees to a fire hazard. |
|
|
343342010
|
0419400
|
2018-07-25
|
200 MCCOMB AVE., SALTILLO, MS, 38866
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2018-07-25
|
Case Closed |
2018-07-31
|
Related Activity
Type |
Inspection |
Activity Nr |
1296895 |
Safety |
Yes |
|
|
342968955
|
0419400
|
2018-02-21
|
200 MCCOMB AVE., SALTILLO, MS, 38866
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-02-22
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2018-06-01
|
Related Activity
Type |
Referral |
Activity Nr |
1311398 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2018-04-05 |
Abatement Due Date |
2018-04-27 |
Current Penalty |
6852.0 |
Initial Penalty |
12934.0 |
Final Order |
2018-04-27 |
Nr Instances |
3 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: (a) Facility - On or about February 21, 2018 employees are exposed to being struck by a cut-off saw blade because the saw guard is not properly adjusted. |
|
|
342597010
|
0419400
|
2017-08-28
|
781 COUNTY ROAD 549, RIPLEY, MS, 38663
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-09-13
|
Emphasis |
N: DUSTEXPL
|
Case Closed |
2017-12-13
|
Related Activity
Type |
Referral |
Activity Nr |
1255914 |
Safety |
Yes |
|
|
342571916
|
0419400
|
2017-08-18
|
1 BAUHAUS DRIVE, SALTILLO, MS, 38866
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-08-18
|
Case Closed |
2017-11-03
|
Related Activity
Type |
Inspection |
Activity Nr |
1214514 |
Health |
Yes |
|
|
342145141
|
0419400
|
2017-03-08
|
1 BAUHAUS DRIVE, SALTILLO, MS, 38866
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-03-09
|
Emphasis |
L: HINOISE
|
Case Closed |
2017-05-09
|
Related Activity
Type |
Complaint |
Activity Nr |
1186784 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100213 I01 |
Issuance Date |
2017-03-29 |
Abatement Due Date |
2017-04-10 |
Current Penalty |
3911.4 |
Initial Penalty |
6519.0 |
Final Order |
2017-04-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: (a) Router Area/ Band saw: On about March 8, 2017, the unused portion on the band saw was not guarded. |
|
|
341666022
|
0419400
|
2016-08-03
|
781 COUNTY ROAD 549, RIPLEY, MS, 38663
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-09-16
|
Emphasis |
N: LEAD
|
Case Closed |
2016-12-14
|
Related Activity
Type |
Referral |
Activity Nr |
1118209 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100095 C01 |
Issuance Date |
2016-10-18 |
Abatement Due Date |
2016-12-02 |
Current Penalty |
1515.6 |
Initial Penalty |
2526.0 |
Final Order |
2016-12-05 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: (a) Woodworking Area - On or about September 8, 2016 a panel saw operator was exposed to an 8-hr TWA of 87.6 dBA or an equivalent dose of 71.5% during a sampling period of 360 minutes on 09/08/16. Exposure calculations include a zero increment for the time not sampled. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100141 D02 II |
Issuance Date |
2016-10-18 |
Abatement Due Date |
2016-12-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-12-05 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: (a) Restrooms - On or about September 8, 2016 the restrooms at the facility was not equipped with hot running water. |
|
|
313631525
|
0419400
|
2010-06-16
|
1199 WEST BANKHEAD STREET, NEW ALBANY, MS, 38652
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2010-06-17
|
Emphasis |
S: POWERED IND VEHICLE, N: DUSTEXPL
|
Case Closed |
2011-08-04
|
Related Activity
Type |
Complaint |
Activity Nr |
207562638 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2010-07-22 |
Abatement Due Date |
2010-08-17 |
Current Penalty |
500.0 |
Initial Penalty |
500.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100037 A03 |
Issuance Date |
2010-07-22 |
Abatement Due Date |
2010-08-17 |
Current Penalty |
500.0 |
Initial Penalty |
500.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2010-07-22 |
Abatement Due Date |
2010-08-17 |
Current Penalty |
500.0 |
Initial Penalty |
500.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 III |
Issuance Date |
2010-07-22 |
Abatement Due Date |
2010-08-17 |
Current Penalty |
500.0 |
Initial Penalty |
500.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040029 A |
Issuance Date |
2010-07-22 |
Abatement Due Date |
2010-09-07 |
Current Penalty |
500.0 |
Initial Penalty |
500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
00 |
|
|
308771377
|
0419400
|
2006-07-14
|
220 SOUTH STREET, SHANNON, MS, 38868
|
|
Inspection Type |
Monitoring
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2006-07-14
|
Case Closed |
2006-07-24
|
Related Activity
Type |
Inspection |
Activity Nr |
308770767 |
|
|
308770767
|
0419400
|
2006-05-16
|
220 SOUTH STREET, SHANNON, MS, 38868
|
|
Inspection Type |
Complaint |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2006-06-09 |
Case Closed |
2006-12-06 |
Related Activity
Type |
Complaint |
Activity Nr |
204192017 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100037 K02 |
Issuance Date |
2006-06-14 |
Abatement Due Date |
2006-07-11 |
Current Penalty |
500.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 IIB |
Issuance Date |
2006-06-14 |
Abatement Due Date |
2006-08-01 |
Current Penalty |
900.0 |
Initial Penalty |
1250.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2006-06-14 |
Abatement Due Date |
2006-07-03 |
Current Penalty |
900.0 |
Initial Penalty |
1250.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100151 B |
Issuance Date |
2006-06-14 |
Abatement Due Date |
2006-08-19 |
Current Penalty |
630.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
14 |
Gravity |
04 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2006-06-14 |
Abatement Due Date |
2006-08-19 |
Current Penalty |
500.0 |
Initial Penalty |
700.0 |
Nr Instances |
3 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19100213 H01 |
Issuance Date |
2006-06-14 |
Abatement Due Date |
2006-07-11 |
Current Penalty |
900.0 |
Initial Penalty |
1250.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19100213 H04 |
Issuance Date |
2006-06-14 |
Abatement Due Date |
2006-07-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2006-06-14 |
Abatement Due Date |
2006-07-11 |
Current Penalty |
370.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 A01 |
Issuance Date |
2006-06-14 |
Abatement Due Date |
2006-07-18 |
Nr Instances |
4 |
Nr Exposed |
15 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100037 Q02 |
Issuance Date |
2006-06-14 |
Abatement Due Date |
2006-07-11 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100178 P01 |
Issuance Date |
2006-06-14 |
Abatement Due Date |
2006-07-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
|