Search icon

Beacon Construction LLC

Company Details

Name: Beacon Construction LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Good Standing
Effective Date: 04 May 2018 (7 years ago)
Business ID: 1145747
ZIP code: 39429
County: Marion
State of Incorporation: MISSISSIPPI
Principal Office Address: 1210 Highway 98 Bypass, 1210 Highway 98 BypassCOLUMBIA, MS 39429

Agent

Name Role Address
Greg Prine Agent 60 Dyess Circle, Columbia, MS 39429

Manager

Name Role Address
GREG K PRINE Manager 1210 Highway 98 Bypass, COLUMBIA, MS 39429

Member

Name Role Address
GREG K PRINE Member 1210 Highway 98 Bypass, COLUMBIA, MS 39429
Beacon Supply Company Inc Member P O Box 968, Columbia, MS 39429

Filings

Type Status Filed Date Description
Annual Report LLC Filed 2024-04-12 Annual Report For Beacon Construction LLC
Annual Report LLC Filed 2023-01-19 Annual Report For Beacon Construction LLC
Annual Report LLC Filed 2022-04-29 Annual Report For Beacon Construction LLC
Annual Report LLC Filed 2021-04-06 Annual Report For Beacon Construction LLC
Annual Report LLC Filed 2020-09-10 Annual Report For Beacon Construction LLC
Notice to Dissolve/Revoke Filed 2020-08-28 Notice to Dissolve/Revoke
Annual Report LLC Filed 2019-04-15 Annual Report For Beacon Construction LLC
Formation Form Filed 2018-04-30 Formation For Beacon Construction LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346088651 0419400 2022-07-19 MS HWY 27 (NORTHBOUND) NEAR HENRY BASS ROAD, MONTICELLO, MS, 39654
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-07-19
Emphasis N: CTARGET, P: CTARGET
Case Closed 2023-04-14

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2022-09-20
Current Penalty 3480.5
Initial Penalty 5801.0
Final Order 2022-10-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1):Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest system: (a) Worksite - Northside box culvert wall: On or about 7/19/2022, an employee was exposed to a fall height of greater than 10 feet while providing instruction to employees inside the box culvert which was being constructed.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261424 A02 II
Issuance Date 2022-09-20
Abatement Due Date 2022-10-13
Current Penalty 2610.5
Initial Penalty 4351.0
Final Order 2022-10-25
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1424(a)(2)(ii): To prevent employees from entering hazard areas, the employer did not erect and maintain control lines, warning lines, railings or similar barriers to mark the boundaries of the hazard areas and/or did not train each employee to understand what these markings signify. Worksite: (a) On or about 7/19/2022, the Link-Belt HSL 138 crane was operated during construction of a culvert and the employer did not erect control lines, warning lines, railings, or similar barriers to mark the boundaries of the hazard areas.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 G08
Issuance Date 2022-09-20
Abatement Due Date 2022-10-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-10-25
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s). (a) Worksite: On or about 7/19/2022, employees were exposed to chemicals such as gasoline, hydraulic fluid, form release, and diesel and the employer did not ensure safety data sheets (SDSs) were maintained in the worksite.
Citation ID 02002
Citaton Type Other
Standard Cited 19260701 B
Issuance Date 2022-09-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-10-25
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b):All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: Northeast side of worksite: (a) On or about 7/19/2022, employees were exposed to unguarded rebar protruding from the ground along a slope.
Citation ID 02003
Citaton Type Other
Standard Cited 19261427 B02
Issuance Date 2022-09-20
Abatement Due Date 2022-10-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-10-25
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1427(b)(2):The trainer did not continuously monitor the operator-in-training on site while operating equipment. (a) Worksite: On or about 7-19-2022, an operator-in-training was permitted to move small equipment with a Link-Belt 138 crane without being continuously monitored.

U.S. Small Business Administration Profile

Status User ID Name of Firm Trade Name UEI Address
Active P2684769 BEACON CONSTRUCTION LLC - HMJZSLDCADA6 1210 HIGHWAY 98 BYP, COLUMBIA, MS, 39429-3703
Capabilities Statement Link -
Phone Number 601-736-2199
Fax Number -
E-mail Address mike.ellis@beaconsupplycompany.com
WWW Page -
E-Commerce Website -
Contact Person MIKE ELLIS
County Code (3 digit) 091
Congressional District 03
Metropolitan Statistical Area -
CAGE Code 99R25
Year Established 2018
Accepts Government Credit Card No
Legal Structure LLC
Ownership and Self-Certifications Self-Certified Small Disadvantaged Business
Business Development Servicing Office MISSISSIPPI DISTRICT OFFICE (SBA office code 0470)
Capabilities Narrative (none given)
Special Equipment/Materials (none given)
Business Type Percentages (none given)
Keywords (none given)
Quality Assurance Standards (none given)
Electronic Data Interchange capable -

SBA Federal Certifications

HUBZone Certified No
Women Owned Certified No
Women Owned Pending No
Economically Disadvantaged Women Owned Certified No
Economically Disadvantaged Women Owned Pending No
Veteran-Owned Small Business Certified No
Veteran-Owned Small Business Joint Venture No
Service-Disabled Veteran-Owned Small Business Certified No
Service-Disabled Veteran-Owned Small Business Joint Venture No

Bonding Levels

Description Construction Bonding Level (per contract)
Level (none given)
Description Construction Bonding Level (aggregate)
Level (none given)
Description Service Bonding Level (per contract)
Level (none given)
Description Service Bonding Level (aggregate)
Level (none given)

NAICS Codes with Size Determinations by NAICS

Primary Yes
Code 237310
NAICS Code's Description Highway, Street, and Bridge Construction
Small Yes

Export Profile (Trade Mission Online)

Exporter Firm hasn't answered this question yet
Export Business Activities (none given)
Exporting to (none given)
Desired Export Business Relationships (none given)
Description of Export Objective(s) (none given)

Date of last update: 23 Feb 2025

Sources: Mississippi Secretary of State