Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-02-15
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2022-07-20
|
Related Activity
Type |
Referral |
Activity Nr |
1865565 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2022-04-15 |
Abatement Due Date |
2022-05-09 |
Current Penalty |
6339.6 |
Initial Penalty |
10566.0 |
Final Order |
2022-05-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces were kept in a clean, orderly, and sanitary condition. (a) No. 1 Blow Fill Machine - On or about February 15, 2022 the employer did not ensure walking-working surfaces were kept in a clean, orderly, and sanitary condition, exposing employees to slip and fall hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 C02 I |
Issuance Date |
2022-04-15 |
Current Penalty |
6339.6 |
Initial Penalty |
10566.0 |
Final Order |
2022-05-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) No. 1 Blow Fill - On or about February 15, 2022 the employer did not guard a rotating shaft exposing employees to a caught-in hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2022-04-15 |
Current Penalty |
5283.6 |
Initial Penalty |
8806.0 |
Final Order |
2022-05-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye. (a) Facility - On or about February 5, 2022, the employer did not report a hospitalization that the employee suffered as a result of work-related injury on February 4th, 2022. The hospitalization was reported on February 10, 2022. |
|
|