Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-01-24
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2023-08-10
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2023-03-07 |
Abatement Due Date |
2023-04-05 |
Current Penalty |
2679.0 |
Initial Penalty |
4465.0 |
Final Order |
2023-04-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. (a) Wet Polish - On or about January 24, 2023, the employer did not ensure walking-working surfaces were free of standing water, exposing employees to slip and fall hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2023-03-07 |
Abatement Due Date |
2023-04-05 |
Current Penalty |
2679.0 |
Initial Penalty |
4465.0 |
Final Order |
2023-04-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. (a) Facility - On or about January 24, 2023 the employer did not have an energy control program for employees that perform servicing and maintenance for 2 Northwood CNC Routers, YUKON Bridge Saw and a Streamline Waterjet Intensifier with energy control procedures, documented training, and periodic inspections, exposing employees to amputation hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100029 B02 |
Issuance Date |
2023-03-07 |
Abatement Due Date |
2023-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-04-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.29(b)(2): The employer did not ensure that guardrail systems met the requirement that midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent intermediate members that are installed between the walking-working surface and the top edge of the guardrail system as follows when there is not a wall or parapet that is at least 21 inches (53 cm) high. (a) Second Level Storage Area - On or about January 24, 2023 storage area guardrail did not have a midrail exposing employees to a fall hazard. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100303 F02 |
Issuance Date |
2023-03-07 |
Abatement Due Date |
2023-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-04-10 |
Nr Instances |
3 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. (a) Facility - On or about January 24, 2023 the employer did not identify the purpose of breakers on electrical breaker cabinets exposing employees to electrical hazards. |
|
Citation ID |
02003A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2023-03-07 |
Abatement Due Date |
2023-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-04-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met. (a) Facility - On or about January 24, 2023, the employer had not developed and implemented a written hazard communication program governing the usage of hazardous chemicals, such as but not limited to, lacquer thinner and integra adhesives, exposing employees to eye and skin irritation when using these products. |
|
Citation ID |
02003B |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2023-03-07 |
Abatement Due Date |
2023-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-04-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Facility - On or about January 24, 2023, the employer did not complete effective information and training to employees that use the following chemical products, but not limited to, lacquer thinner and integra adhesives, exposing the employees to eye and skin irritation when using these products. |
|
|