Search icon

Five Star Products, Inc.

Branch

Company Details

Name: Five Star Products, Inc.
Jurisdiction: MISSISSIPPI
Business Type: Profit Corporation
Status: Good Standing
Effective Date: 22 Dec 2020 (4 years ago)
Branch of: Five Star Products, Inc., CONNECTICUT (Company Number 0110765)
Business ID: 1249947
State of Incorporation: CONNECTICUT
Principal Office Address: 2 ENTERPRISE DRIVE, STE. 303Shelton, CT 06484
Fictitious names: Five Star Marine

Agent

Name Role Address
CORPORATION SERVICE COMPANY Agent 109 Executive Drive, Suite 3, Madison, MS 39110

Director

Name Role Address
Lawrence Shapiro Director 2 Enterprise Drive, Ste. 303, Shelton, CT 06484
Charles N. Babcock Director 2 Enterprise Drive, Ste. 303, Shelton, CT 06484
Kevin B. Murphy Director 2 Enterprise Drive, Ste. 303, Shelton, CT 06484
Daniel M. Harrington Director 2 Enterprise Drive, Ste. 303, Shelton, CT 06484
William F. Childs, IV Director 2 Enterprise Drive, Ste. 303, Shelton, CT 06484
Kari Saragusa Director 2 Enterprise Drive, Ste. 303, Shelton, CT 06484

Vice President

Name Role Address
Lawrence Shapiro Vice President 2 Enterprise Drive, Ste. 303, Shelton, CT 06484
Atom Saverse Vice President 2 Enterprise Drive, Ste. 303, Shelton, CT 06484

Treasurer

Name Role Address
Jeff Riveness Treasurer 2 Enterprise Drive, Ste. 303, Shelton, CT 06484

Chief Financial Officer

Name Role Address
Jeff Riveness Chief Financial Officer 2 Enterprise Drive, Ste. 303, Shelton, CT 06484

Secretary

Name Role Address
Charles N. Babcock Secretary 2 Enterprise Drive, Ste. 303, Shelton, CT 06484

Chairman

Name Role Address
Daniel M. Harrington Chairman 2 Enterprise Drive, Ste. 303, Shelton, CT 06484

Filings

Type Status Filed Date Description
Annual Report Filed 2024-02-22 Annual Report For Five Star Products, Inc.
Annual Report Filed 2024-01-30 Annual Report For Five Star Products, Inc.
Annual Report Filed 2023-02-21 Annual Report For Five Star Products, Inc.
Registered Agent Change of Address Filed 2022-03-31 Agent Address Change For CORPORATION SERVICE COMPANY
Annual Report Filed 2022-03-31 Annual Report For Five Star Products, Inc.
Annual Report Filed 2021-06-18 Annual Report For Five Star Products, Inc.
Fictitious Name Registration Filed 2021-01-06 Fictitious Name Registration For Five Star Products, Inc.
Merger Filed 2020-12-23 Merger For Five Star Products, Inc.
Formation Form Filed 2020-12-22 Formation For Five Star Products, Inc.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340017177 0419400 2014-10-14 2910 CR 501, RIPLEY, MS, 38663
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2014-10-14
Emphasis L: FORKLIFT
Case Closed 2014-10-19

Related Activity

Type Inspection
Activity Nr 977410
Health Yes
339774101 0419400 2014-05-16 2910 CR 501, RIPLEY, MS, 38663
Inspection Type Complaint
Scope Complete
Safety/Health Health
Close Conference 2014-07-23
Case Closed 2015-01-06

Related Activity

Type Complaint
Activity Nr 889706
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100107 C05
Issuance Date 2014-08-12
Abatement Due Date 2014-09-08
Current Penalty 1512.0
Initial Penalty 2520.0
Final Order 2014-10-03
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(c)(5): The employer failed to ensure that locations containing both deposits of readily ignitable residue and explosive vapors, there was not electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections. (a) Lay Up - On or about May 16, 2014 deposits of the resin containing methyl ethyl ketone a flammable substance had accumulated on the electrical panels. The panels were not approved Class 1 hazardous locations.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100107 E09
Issuance Date 2014-08-12
Abatement Due Date 2014-09-08
Current Penalty 1512.0
Initial Penalty 2520.0
Final Order 2014-10-03
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(e)(9): 29 CFR 1910.107(e)(9): Flammable liquids for use in spraying operations were transferred from one container to another without both containers being effectively bonded and grounded to prevent discharge sparks of static electricity. (a) Storage Room - On or about May 16, 2014 the resin mixture (Flammable) is poured from a 50 gallon drum to a smaller container. The containers are not bonded and grounded.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2014-08-12
Abatement Due Date 2014-09-29
Current Penalty 972.0
Initial Penalty 1620.0
Final Order 2014-10-03
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Lay Up - On or about May 16, 2014 employees required to wear negative pressure respirators had not received a medical evaluation.
Citation ID 02001
Citaton Type Other
Standard Cited 19100107 G07
Issuance Date 2014-08-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-10-03
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(g)(7): "No smoking" signs in large letters on contrasting color backgrounds were not conspicuously posted at all spraying areas and the paint storage rooms: (a) Lay Up Area - On or about May 16, 2014 employees spray flammable resin in the area without a sign stating "No Smoking".
Citation ID 02002
Citaton Type Other
Standard Cited 19100134 C01
Issuance Date 2014-08-12
Abatement Due Date 2014-09-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-10-03
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Lay Up - On or about May 16, 2014 a written respiratory program had not been developed for employees required to wear negative pressure respiratory protection.

Date of last update: 27 Feb 2025