Filings

Type Status Filed Date Description
Admin Dissolution Filed 2024-12-01 Action of Intent to Dissolve: AR: Victor Jr. Roofing LLC
Notice to Dissolve/Revoke Filed 2024-09-01 Notice of Intent to Dissolve: AR: Victor Jr. Roofing LLC
Annual Report LLC Filed 2023-08-03 Annual Report For Victor Jr. Roofing LLC
Formation Form Filed 2022-04-22 Formation For Victor Jr. Roofing LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346227044 0419400 2022-09-14 15373 SAINT CHARLES ST, GULFPORT, MS, 39503
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2022-09-14
Emphasis L: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1622696
Safety Yes
Type Inspection
Activity Nr 1622690
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2022-12-13
Abatement Due Date 2023-01-06
Current Penalty 3108.0
Initial Penalty 3108.0
Final Order 2023-01-26
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) North side of building- On or about September 14, 2022, employees were exposed to a fall hazard while working on edge of the roof without any flagging, personal fall arrest systems, or safety net systems.
Citation ID 02001
Citaton Type Other
Standard Cited 19100178 L06
Issuance Date 2022-12-13
Abatement Due Date 2023-01-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-01-26
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) North side of building- On or about September 14, 2022, the employer did certify that an employee operating Genie All Terrain Forklift N94348 had been trained.
Citation ID 02002
Citaton Type Other
Standard Cited 19261053 B01
Issuance Date 2022-12-13
Abatement Due Date 2023-01-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-01-26
Nr Instances 2
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. (a) (LOCATION) (IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS) (a) North side of building - On or about September 14, 2022, employees used an aluminum extension ladder to gain access to the upper level that did not extend 3 feet above the landing surface, exposing them to fall hazards.