342984507
|
0419400
|
2018-03-01
|
504 DEWEY AVE, OCEAN SPRINGS, MS, 39564
|
|
Inspection Type |
FollowUp
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2018-03-01
|
Emphasis |
L: FALL
|
Case Closed |
2018-03-05
|
Related Activity
Type |
Inspection |
Activity Nr |
1243080 |
Safety |
Yes |
|
|
342430808
|
0419400
|
2017-06-28
|
504 DEWEY AVE., OCEAN SPRINGS, MS, 39564
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-06-28
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-11-02
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2017-08-23 |
Abatement Due Date |
2017-08-25 |
Current Penalty |
2000.0 |
Initial Penalty |
3803.0 |
Final Order |
2017-09-08 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) (a) North and South exterior of house - On or about June 28, 2017 employees were working from welded tubular framed scaffolding applying siding to exterior of house that was not fully planked. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2017-08-23 |
Abatement Due Date |
2017-08-25 |
Current Penalty |
2000.0 |
Initial Penalty |
3803.0 |
Final Order |
2017-09-08 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: (a) North and south side of house - On or about June 28, 2017 employees applying siding to exterior of house were working on tubular framed scaffolding where the support post were not on base plates or firm foundation. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260454 A |
Issuance Date |
2017-08-23 |
Abatement Due Date |
2017-08-31 |
Current Penalty |
2000.0 |
Initial Penalty |
3803.0 |
Final Order |
2017-09-08 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) North and South side of house - On or about June 28, 2017 employees were working from welded tubular scaffolding applying siding to house wall that were not trained by a person qualified to recognize hazards. |
|
|