Search icon

United Solutions, Corp

Company Details

Name: United Solutions, Corp
Jurisdiction: MISSISSIPPI
Business Type: Profit Corporation
Status: Good Standing
Effective Date: 01 Jan 2025 (4 months ago)
Business ID: 1468752
State of Incorporation: MISSISSIPPI

Agent

Name Role Address
JC Scott Agent 7375 AYLESBURY LN, OLIVE BRANCH, MS 38654-9686

Incorporator

Name Role Address
JC Scott III Incorporator 7375 AYLESBURY LN, OLIVE BRANCH, MS 38654-9686

Filings

Type Status Filed Date Description
Formation Form Filed 2024-12-14 Formation For United Solutions, Corp

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345338172 0419400 2021-05-28 1052 INDUSTRIAL PARK RD., SARDIS, MS, 38666
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2021-08-10
Emphasis L: HINOISE, P: HINOISE
Case Closed 2021-09-24
342651106 0419400 2017-09-15 INDUSTRIAL DRIVE, SARDIS, MS, 38666
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2017-09-15
Case Closed 2017-12-13

Related Activity

Type Complaint
Activity Nr 1262068
Safety Yes
Health Yes
339075392 0419400 2013-05-16 INDUSTRIAL DRIVE, SARDIS, MS, 38666
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2013-05-16
Emphasis L: HINOISE
Case Closed 2013-05-28

Related Activity

Type Inspection
Activity Nr 800401
Health Yes
338004013 0419400 2012-12-07 INDUSTRIAL DRIVE, SARDIS, MS, 38666
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2013-01-03
Emphasis L: HINOISE
Case Closed 2013-05-03

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C04 II B
Issuance Date 2013-01-29
Abatement Due Date 2013-03-18
Current Penalty 1417.8
Initial Penalty 2363.0
Final Order 2013-02-08
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. (a) Plastic Line - On or about December 11, 2012 specific lockout procedures had not been developed for employees working on injection molding machines on plactic line.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100303 F02
Issuance Date 2013-01-29
Abatement Due Date 2013-02-25
Current Penalty 850.8
Initial Penalty 1418.0
Final Order 2013-02-08
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Front, Office - On or about December 11, 2012 circuit breaker lectrical panel controling office power was not labeled.
Citation ID 02001
Citaton Type Other
Standard Cited 19100146 C03
Issuance Date 2013-01-29
Abatement Due Date 2013-03-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-02-08
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(c)(3): When the employer decided that its employees would not enter permit spaces, the employer did not comply with 29 CFR 1910.146(c)(1), 29 CFR 1910.146(c)(2), 29 CFR 1910.146(c)(6), and 29 CFR 1910.146(c)(8: (a) Vessells, Outside - On or about December 7, 2012 the employer failed to evaluate the workplace and post the signs indicating the vessels containing propylene pellets as a confined space.

Date of last update: 26 Mar 2025

Sources: Mississippi Secretary of State