Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100028 B01 I |
Issuance Date |
2021-09-17 |
Abatement Due Date |
2021-10-12 |
Current Penalty |
1755.6 |
Initial Penalty |
2926.0 |
Final Order |
2021-10-14 |
Nr Instances |
3 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(1)(i): 29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): (a) Repair bays - On or about March 25, 2021 the employer allowed employees to work from the tops of recreational vehicles without fall protection exposing employees to fall hazards of up to 12'. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100213 D01 |
Issuance Date |
2021-09-17 |
Abatement Due Date |
2021-10-12 |
Current Penalty |
1404.6 |
Initial Penalty |
2341.0 |
Final Order |
2021-10-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(d)(1):Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: (a) Repair bay on east side of facility - On or about March 25, 2021 the employer allowed carpenters to operate Craftsman table saw that was not guarded exposing employees to amputation hazard. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2021-09-17 |
Abatement Due Date |
2021-10-12 |
Current Penalty |
1053.0 |
Initial Penalty |
1755.0 |
Final Order |
2021-10-14 |
Nr Instances |
6 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed: (a) Repair bay on east side of facility - On or about March 25, 2021 the employer allowed employees use a circuit breaker panel that was missing panel blanks and a quad-outlet box that had two knockouts missing exposing employees to electrical shock. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 I |
Issuance Date |
2021-09-17 |
Abatement Due Date |
2021-10-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i):Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) Repair bay on east side of facility - On or about March 25, 2021 duplex outlet box powering chop saw and cell phone charging block did not have a cover exposing employees to an electrical shock hazard. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2021-09-17 |
Abatement Due Date |
2021-10-12 |
Current Penalty |
1053.0 |
Initial Penalty |
1755.0 |
Final Order |
2021-10-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1):Employer had not developed or implemented a written hazard communication program including the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (a) Facility - On or about March 25, 2021 employees used chemical products such as, but not limited to, automotive paint, roof sealant, body filler and the employer did not have a written hazard communication program exposing employees to respiratory illnesses. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2021-09-17 |
Abatement Due Date |
2021-10-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-14 |
Nr Instances |
10 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): (a) Facility - On or about March 25, 2021 employees used chemical products such as, but not limited to, Polyester Resin Marine Grade, EVERCOAT Kitty Hair Fiberglass Reinforced Body Filler, Lesonal Basecoat SB, dicor products - LAP SEALANT 501LSD (contains naphtha)and the employer did not have safety data sheets exposing employees to respiratory illnesses. |
|
Citation ID |
01004C |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2021-09-17 |
Abatement Due Date |
2021-10-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Repair bays and paint spray room - On or about March 25, 2021 employees used chemical products such as, but not limited to, automotive paint, lap sealant and the employer did not provide training as required exposing employees to respiratory illnesses. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100132 D02 |
Issuance Date |
2021-09-17 |
Abatement Due Date |
2021-10-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: (a) Facility - On or about March 25, 2021 the employer did not verify that an assessment of the workplace had been conducted to identify hazards that would require the use of personal protective equipment exposing employees to fall hazards. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100333 B02 I |
Issuance Date |
2021-09-17 |
Abatement Due Date |
2021-10-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-10-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.333(b)(2)(i):The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives: (a) Repair bays - On or about March 25, 2021 the employer allowed employees to repair, replace and service recreational vehicles' and travel trailers' electrical systems, components and appliances and the employer did not have written energy control procedures (lockout tagout) exposing employees to electrical shock hazards. |
|