Search icon

ENVIRONMENTAL CONSTRUCTION CORP.

Company Details

Name: ENVIRONMENTAL CONSTRUCTION CORP.
Jurisdiction: MISSISSIPPI
Business Type: Profit Corporation
Status: Good Standing
Effective Date: 21 Jul 1975 (50 years ago)
Business ID: 210918
ZIP code: 39571
County: Harrison
State of Incorporation: MISSISSIPPI
Principal Office Address: 105 Palmwood Dr.PASS CHRISTIAN, MS 39571

Agent

Name Role Address
Michelle S. McNair Agent 105 Palmwood Dr., Pass Christian, MS 39571

Director

Name Role Address
Claude D. Thompson Director 408 Oak Alley, Houma, LA 70360
Dale C. Thompson Jr. Director 303 Oak Alley, Houma, LA 70360

President

Name Role Address
Claude D. Thompson President 408 Oak Alley, Houma, LA 70360

Vice President

Name Role Address
Dale C. Thompson Jr. Vice President 303 Oak Alley, Houma, LA 70360

Filings

Type Status Filed Date Description
Annual Report Filed 2024-04-08 Annual Report For ENVIRONMENTAL CONSTRUCTION CORP.
Annual Report Filed 2023-02-16 Annual Report For ENVIRONMENTAL CONSTRUCTION CORP.
Annual Report Filed 2022-01-18 Annual Report For ENVIRONMENTAL CONSTRUCTION CORP.
Amendment Form Filed 2021-01-27 Amendment For ENVIRONMENTAL CONSTRUCTION CORP.
Annual Report Filed 2021-01-07 Annual Report For ENVIRONMENTAL CONSTRUCTION CORP.
Annual Report Filed 2020-05-14 Annual Report For ENVIRONMENTAL CONSTRUCTION CORP.
Amendment Form Filed 2020-02-21 Amendment For ENVIRONMENTAL CONSTRUCTION CORP.
Amendment Form Filed 2019-08-08 Amendment For ENVIRONMENTAL CONSTRUCTION CORP.
Annual Report Filed 2019-03-22 Annual Report For ENVIRONMENTAL CONSTRUCTION CORP.
Annual Report Filed 2018-03-13 Annual Report For ENVIRONMENTAL CONSTRUCTION CORP.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337902217 0419400 2012-12-12 125 CHURCH AVE., PASS CHRISTIAN, MS, 39571
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-12-18
Emphasis L: FALL, P: FALL
Case Closed 2014-02-05

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2013-01-28
Abatement Due Date 2013-02-14
Current Penalty 400.0
Initial Penalty 1600.0
Final Order 2013-02-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a. Trinity Episcopal Church, 125 Church Ave, Pass Christian MS - On or about December 12, 2012 the grounding prong was missing from a yellow heavy duty extension cord that supplied power to a spray washer.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261431 B01
Issuance Date 2013-01-28
Abatement Due Date 2013-02-14
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2013-02-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1431(b)(1): When using equipment to hoist employees, the employees must be in a personnel platform that meets the requirements of paragraph (e) of this section. a. Trinity Episcopal Church, 125 Church Ave, Pass Christian MS - On or about December 12, 2012 employees were observed using a man basket that was not built in accordance with 1926.1431(e). The man basket had the following discrepancies: 1. The basket did not have standard guardrails; 1926.1431(e)(6). 2. The basket did not have grab rails installed on the inside; 1926.1431(e)(7). 3. The basket did not have overhead protection to prevent the employee from being struck by overhead objects. The employee is standing directly beneath the overhaul ball when inside the basket; 1926.1431(e)(10). 4. The basket was not weight tested. The basket should be weight tested and marked with the rated capacity; 1926.1431(e)(12.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261431 D05 V
Issuance Date 2013-01-28
Abatement Due Date 2013-02-14
Current Penalty 1800.0
Initial Penalty 2800.0
Final Order 2013-02-12
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1431(d)(5)(v): Anti two-block. A device which automatically prevents damage and load failure from contact between the load block, overhaul ball, or similar component, and the boom tip (or fixed upper block or similar component) must be used. The device(s) must prevent such damage/failure at all points where two-blocking could occur. Exception: This device is not required when hoisting personnel in pile driving operations. Instead, paragraph (p)(2) of this section specifies how to prevent two-blocking during such operations. a. Trinity Episcopal Church, 125 Church Ave., Pass Chirstian MS - On or about December 12, 2012 a truck crane that was used to lift an employee in a man basket was not equipped with an anti two-block device.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261427 F05
Issuance Date 2013-01-28
Abatement Due Date 2013-02-14
Current Penalty 900.0
Initial Penalty 2000.0
Final Order 2013-02-12
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1427(f)(5): The operator-in-training must not operate the equipment in any of the following circumstances (29 CFR 1926.1427(f)(5)(i) through (f)(5)(iv)) unless the exception stated in paragraph (f)(5)(v) of this section is applicable: a. Trinity Episcopal Church, 125 Church Ave, Pass Chirstian MS - On or about December 12, 2012 a crane operator was observed using a Manitex 1770C truck mounted crane to lift an employee that was in a man basket. The crane operator was not fully trained on the Manitex 1770C truck mounted crane; the crane operator was not trained to lift personnel with the crane.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261431 K10 I
Issuance Date 2013-01-28
Abatement Due Date 2013-02-14
Current Penalty 700.0
Initial Penalty 1600.0
Final Order 2013-02-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1431(k)(10)(i): Except over water, employees occupying the personnel platform must be provided and use a personal fall arrest system. The system must be attached to a structural member within the personnel platform. When working over or near water, the requirements of 1926.106 apply. a. Trinity Episcopal Church, 125 Church Ave, Pass Christian MS - On or about December 12, 2012 an employee was elevated in a man basket without wearing a personal fall arrest system.
101559771 0419400 1986-11-19 VIDALIA RD., PASS CHRISTIAN, MS, 39571
Inspection Type Planned
Scope NoInspection
Safety/Health Safety
Close Conference 1986-11-19
Case Closed 1986-11-21

Date of last update: 16 Apr 2025

Sources: Mississippi Secretary of State