Search icon

METRO AUTO PAINTING, INC.

Company Details

Name: METRO AUTO PAINTING, INC.
Jurisdiction: MISSISSIPPI
Business Type: Profit Corporation
Status: Dissolved
Effective Date: 11 Jan 1979 (46 years ago)
Business ID: 211559
ZIP code: 39157
County: Madison
State of Incorporation: MISSISSIPPI
Principal Office Address: 743 Ridgewood Rd, 743 Ridgewood RdRidgeland, MS 39157

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
401K EMPLOYEE RETIREMENT PLAN 2023 640621598 2024-07-22 METRO AUTO PAINTING, INC. 12
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2022-01-01
Business code 811120
Sponsor’s telephone number 6019564009
Plan sponsor’s address 743 RIDGEWOOD ROAD, RIDGELAND, MS, 39157

Plan administrator’s name and address

Administrator’s EIN 452557054
Plan administrator’s name RETIREMENT PLAN SERVICES, LLC
Plan administrator’s address 4209 LAKELAND DRIVE, FLOWOOD, MS, 39232
Administrator’s telephone number 6019191023

Signature of

Role Plan administrator
Date 2024-07-22
Name of individual signing SCOTT HILL
Valid signature Filed with authorized/valid electronic signature
401K EMPLOYEE RETIREMENT PLAN 2022 640621598 2023-07-21 METRO AUTO PAINTING, INC. 0
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2022-01-01
Business code 811120
Sponsor’s telephone number 6019564009
Plan sponsor’s address 743 RIDGEWOOD ROAD, RIDGELAND, MS, 39157

Plan administrator’s name and address

Administrator’s EIN 452557054
Plan administrator’s name RETIREMENT PLAN SERVICES, LLC
Plan administrator’s address 4209 LAKELAND DRIVE, FLOWOOD, MS, 39232
Administrator’s telephone number 6019191023

Signature of

Role Plan administrator
Date 2023-07-21
Name of individual signing SCOTT HILL
Valid signature Filed with authorized/valid electronic signature

Agent

Name Role Address
RICHARD WAYNE DALLAS Agent 743 RIDGEWOOD RD, RIDGELAND, MS 39157

Incorporator

Name Role Address
Richard Wayne Dallas Incorporator 3111 Lynch St, Jackson, MS 39209
Sherry Lea Dallas Incorporator Route 1 Box 110, Pickens, MS 39209

Director

Name Role Address
Shane J. Thomas Director 743 Ridgewood Rd, Ridgeland, MS 39157

President

Name Role Address
Shane J. Thomas President 743 Ridgewood Rd, Ridgeland, MS 39157

Filings

Type Status Filed Date Description
Admin Dissolution Filed 2024-12-01 Action of Intent to Dissolve: AR: METRO AUTO PAINTING, INC.
Notice to Dissolve/Revoke Filed 2024-09-01 Notice of Intent to Dissolve: AR: METRO AUTO PAINTING, INC.
Annual Report Filed 2023-02-23 Annual Report For METRO AUTO PAINTING, INC.
Annual Report Filed 2022-03-08 Annual Report For METRO AUTO PAINTING, INC.
Annual Report Filed 2021-01-28 Annual Report For METRO AUTO PAINTING, INC.
Annual Report Filed 2020-03-18 Annual Report For METRO AUTO PAINTING, INC.
Annual Report Filed 2019-03-05 Annual Report For METRO AUTO PAINTING, INC.
Annual Report Filed 2018-03-14 Annual Report For METRO AUTO PAINTING, INC.
Annual Report Filed 2017-04-10 Annual Report For METRO AUTO PAINTING, INC.
Annual Report Filed 2016-03-31 Annual Report For METRO AUTO PAINTING, INC.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344316476 0419400 2019-09-10 743 RIDGEWOOD ROAD, RIDGELAND, MS, 39157
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2019-09-10
Emphasis L: LEAD, N: LEAD, P: LEAD
Case Closed 2020-08-06

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2020-03-05
Abatement Due Date 2020-03-27
Current Penalty 1387.8
Initial Penalty 2313.0
Final Order 2020-03-20
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Facility - On or about September 10, 2019 the employer did not develop a respiratory protection a written respiratory protection program governing the usage of a 3M, negative pressure, half mask, air purifying respirator used in the workplace exposing employees to respirable hazards.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2020-03-05
Abatement Due Date 2020-03-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-20
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Facility - On or about September 10, 2019, the employer did not provide a medical evaluation for employees required to use a 3M, negative pressure, half mask, air purifying respirator in the workplace, exposing employees to respiratory system hazards.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 K
Issuance Date 2020-03-05
Abatement Due Date 2020-03-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-20
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k): The employer did not provide comprehensive, understandable, and effective annual training to employees who were required to use respirators: (a) Facility - On or about September 10, 2019, the employer did not provide the employees with adequate training for employees required to use a 3M, negative pressure, half mask, air purifying respirator exposing employees to respirable hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100141 A03 I
Issuance Date 2020-03-05
Abatement Due Date 2020-03-27
Current Penalty 1387.8
Initial Penalty 2313.0
Final Order 2020-03-20
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed: (a) Body Shop - On or about September 10, 2019 the bathroom was not maintained in a sanitary condition exposing the employees to germs and other potential infectious diseases.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100253 B02 II
Issuance Date 2020-03-05
Abatement Due Date 2020-03-13
Current Penalty 1850.4
Initial Penalty 3084.0
Final Order 2020-03-20
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior: (a) Body Shop Area - On or about September 10, 2019 employees were exposed to a struck by hazard due to the acetylene cylinder not being secured. (b) Body Shop Area - On or about September 10, 2019 employees were exposed to a struck by hazard due to the oxygen cylinder not being secured.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100253 B04 III
Issuance Date 2020-03-05
Abatement Due Date 2020-03-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-20
Nr Instances 2
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: (a) Body shop - On or about September 10, 2019 the employer stored acetylene and oxygen cylinders together exposing the employees to fire hazards.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100303 B02
Issuance Date 2020-03-05
Abatement Due Date 2020-03-13
Current Penalty 1850.4
Initial Penalty 3084.0
Final Order 2020-03-20
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Facility - On or about September 10, 2019 three electrical boxes used for temporary power were not mounted exposing the employees to an electrical shock hazard.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100305 B02 I
Issuance Date 2020-03-05
Abatement Due Date 2020-03-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-20
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) Paint booth - On or about September 10, 2019 the electrical junction box did not have a cover over the live electrical wires exposing the employees to an electrical shock hazard.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2020-03-05
Abatement Due Date 2020-03-27
Current Penalty 1387.8
Initial Penalty 2313.0
Final Order 2020-03-20
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Facility - On or about September 10, 2019 the employer did not develop a written hazard communication program providing information to employees about the chemicals they are exposed to in the workplace such as but not limited lacquer thinner, primer, paints and other hazardous chemicals exposing the employees to chemical hazards.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2020-03-05
Abatement Due Date 2020-03-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-20
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Facility - On or about September 10, 2019 the employer did not provide training on the chemicals they are exposed to in the workplace such as but not limited lacquer thinner, primer, paints and other hazardous chemicals exposing the employees to chemical hazards.
Citation ID 02001
Citaton Type Other
Standard Cited 19100106 E06 I
Issuance Date 2020-03-05
Abatement Due Date 2020-03-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-20
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat: (a) Flammable storage Area - "No Smoking" signs were not posted in or near the flammable storage area exposing the employees to a fire hazard.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4868057110 2020-04-13 0470 PPP 743 RIDGEWOOD RD 743 RIDGEWOOD RD, RIDGELAND, MS, 39157
Loan Status Date 2022-02-19
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 151285
Loan Approval Amount (current) 151285
Undisbursed Amount 0
Franchise Name -
Lender Location ID 188567
Servicing Lender Name Loan Source Incorporated
Servicing Lender Address 353 East 83rd Street Suite 3H, NEW YORK, NY, 10028
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address RIDGELAND, MADISON, MS, 39157-0002
Project Congressional District MS-03
Number of Employees 13
NAICS code 811121
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 39848
Originating Lender Name Cadence Bank
Originating Lender Address TUPELO, MS
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 153320.09
Forgiveness Paid Date 2021-08-26

Date of last update: 16 Apr 2025

Sources: Mississippi Secretary of State