Name: | THREE S ENTERPRISES, INC. |
Jurisdiction: | MISSISSIPPI |
Business Type: | Profit Corporation |
Status: | Dissolved |
Effective Date: | 19 Jul 1977 (48 years ago) |
Business ID: | 301454 |
State of Incorporation: | MISSISSIPPI |
Principal Office Address: | 53 Major Ridge RoadRinggold, GA 30736 |
Name | Role | Address |
---|---|---|
Lisa Seago | Agent | 6308 Burris Road, Smithdale, MS 39664 |
Name | Role | Address |
---|---|---|
Etta Seago | Director | 53 Major Ridge Road, Ringold, GA 30736 |
Name | Role | Address |
---|---|---|
Etta Seago | President | 53 Major Ridge Road, Ringold, GA 30736 |
Name | Role | Address |
---|---|---|
Etta Seago | Treasurer | 53 Major Ridge Road, Ringold, GA 30736 |
Name | Role | Address |
---|---|---|
Sharon Seago Henley | Vice President | 53 Major Ridge Road, Ringgold, GA 30736 |
Name | Role | Address |
---|---|---|
Sharon Seago Henley | Secretary | 53 Major Ridge Road, Ringgold, GA 30736 |
Type | Status | Filed Date | Description |
---|---|---|---|
Dissolution | Filed | 2025-03-07 | Dissolution For THREE S ENTERPRISES, INC. |
Amendment Form | Filed | 2024-09-09 | Amendment For THREE S ENTERPRISES, INC. |
Annual Report | Filed | 2024-04-15 | Annual Report For THREE S ENTERPRISES, INC. |
Annual Report | Filed | 2023-04-13 | Annual Report For THREE S ENTERPRISES, INC. |
Annual Report | Filed | 2022-04-15 | Annual Report For THREE S ENTERPRISES, INC. |
Annual Report | Filed | 2021-04-14 | Annual Report For THREE S ENTERPRISES, INC. |
Annual Report | Filed | 2020-04-08 | Annual Report For THREE S ENTERPRISES, INC. |
Annual Report | Filed | 2019-04-04 | Annual Report For THREE S ENTERPRISES, INC. |
Merger | Filed | 2018-06-11 | Merger For THREE S ENTERPRISES, INC. |
Correction Amendment Form | Filed | 2018-05-03 | Correction For THREE S ENTERPRISES, INC. |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342479656 | 0419400 | 2017-07-18 | 614 W. PRESLEY BLVD., MCCOMB, MS, 39648 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1239999 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2017-09-07 |
Abatement Due Date | 2017-09-11 |
Current Penalty | 2719.75 |
Initial Penalty | 4945.0 |
Final Order | 2017-09-22 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a) On or about July 18, 2017 a employee left middle ring finger was amputated due to the guards on the Edger were not affixed to protect from rotating chains and sprockets. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2016-07-06 |
Emphasis | N: AMPUTATE |
Case Closed | 2018-01-03 |
Related Activity
Type | Referral |
Activity Nr | 1107987 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100147 C02 II |
Issuance Date | 2016-12-20 |
Abatement Due Date | 2017-01-13 |
Current Penalty | 6000.0 |
Initial Penalty | 8730.0 |
Final Order | 2017-01-11 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(2)(ii): An energy isolating device that was capable of being locked out, did not utilize a lockout device, which rendered the machine or equipment inoperative: (a) Jobsite - On or about June 24, 2016, an employee was clearing a jammed board on the Double Head Notcher and the equipment was not locked out to prevent accidental startup. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100147 C04 I |
Issuance Date | 2016-12-20 |
Abatement Due Date | 2017-01-13 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-01-11 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Jobsite - On or about June 24, 2016, the employer had not developed energy control procedures for the Double Head Notcher. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100303 B01 VIII |
Issuance Date | 2016-12-20 |
Current Penalty | 6000.0 |
Initial Penalty | 8730.0 |
Final Order | 2017-01-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(b)(1)(viii): Electrical equipment was not free from recognized hazards based on other factors that contribute to the practical safeguarding of persons using or likely to come in contact with the equipment: (a) Jobsite - On or about June 24, 2016, the labeling on the electrical control panel on the Double Head Notcher was not durable enough to allow proper identification of each control. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19040039 A02 |
Issuance Date | 2016-12-20 |
Current Penalty | 0.0 |
Initial Penalty | 3500.0 |
Final Order | 2017-01-11 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours: (a) Facility - On or about June 24, 2016 an employee was involved in a work-related accident which resulted in the amputation of two fingers. The employer failed to report the incident to the Occupational Safety and Health Administration (OSHA) as required. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2015-06-17 |
Emphasis | N: AMPUTATE, L: FORKLIFT, P: AMPUTATE |
Case Closed | 2015-08-04 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100023 D01 III |
Issuance Date | 2015-07-21 |
Current Penalty | 1890.0 |
Initial Penalty | 3150.0 |
Final Order | 2015-07-31 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.23(d)(1)(iii): Flight(s) of stairs with 4 or more risers, less than 44 inches wide and having both sides open were not equipped with one standard stair railing on each side: East Saw Mill - On or about June 17, 2015, the stairs leading to the saw platform were not equipped with a handrail on each side. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6754287306 | 2020-04-30 | 0470 | PPP | 614 W Presley Blvd, MCCOMB, MS, 39648-5306 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4489998302 | 2021-01-23 | 0470 | PPS | 614 W Presley Blvd, McComb, MS, 39648-5306 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|