Name: | TRIANGLE CONSTRUCTION COMPANY, INC. |
Jurisdiction: | MISSISSIPPI |
Business Type: | Profit Corporation |
Status: | Dissolved |
Effective Date: | 28 Dec 1959 (65 years ago) |
Business ID: | 425720 |
State of Incorporation: | MISSISSIPPI |
Principal Office Address: | 503 BARNETT BUILDINGJACKSON, MS |
Name | Role | Address |
---|---|---|
DALE H MCKIBBEN | Incorporator | 129 PASA ROBLES, JACKSON, MS |
HAROLD JAMES | Incorporator | 270 IRIS AVENUE, JACKSON, MS |
Type | Status | Filed Date | Description |
---|---|---|---|
Admin Dissolution | Filed | 1989-05-01 | Admin Dissolution |
Notice to Dissolve/Revoke | Filed | 1963-11-12 | Notice to Dissolve/Revoke |
Undetermined Event | Filed | 1960-01-01 | Undetermined Event |
Name Reservation Form | Filed | 1959-12-28 | Name Reservation |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341012722 | 0419400 | 2015-10-22 | 222 TAYLOR STREET, JACKSON, MS, 39216 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1103243 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1101288 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1101296 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1101185 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2015-12-15 |
Abatement Due Date | 2015-12-17 |
Current Penalty | 1122.0 |
Initial Penalty | 1870.0 |
Final Order | 2016-01-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. (a) Front of Taylor Court 2 - On or about October 22, 2015 an employee was exposed to a falling object hazard while working beneath loose soil inside a 5.8 feet deep trench including the spoil pile. This employee was not wearing hardhats while an excavator was in operation. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260651 C02 |
Issuance Date | 2015-12-15 |
Abatement Due Date | 2015-12-17 |
Current Penalty | 1346.4 |
Initial Penalty | 2244.0 |
Final Order | 2016-01-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees. (a) Front of Taylor Court 2 - On or about October 22, 2015 an employee was working inside a 5.8 feet deep trench including the spoil pile with no means of egress. There was no ladder in the trench. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260651 J02 |
Issuance Date | 2015-12-15 |
Abatement Due Date | 2015-12-17 |
Current Penalty | 1848.0 |
Initial Penalty | 3080.0 |
Final Order | 2016-01-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(j)(2): Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. (a) Front of Taylor Court 2 - On or about October 22, 2015 an employee was working inside a 5.8 feet deep trench with spoil pile directly next to the excavation. The spoil pile was not 2 feet away from the edge of the excavation. |
Date of last update: 02 Feb 2025