Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-03-07
|
Emphasis |
N: SSTARG12, L: FORKLIFT, P: SSTARG12
|
Case Closed |
2013-06-19
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II C |
Issuance Date |
2013-05-24 |
Abatement Due Date |
2013-06-13 |
Current Penalty |
2160.0 |
Initial Penalty |
3600.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii)(C): Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. (a) Viking Range, East Plant - On or about March 26, 2013 specific procedures for controlling hazardous energy when performing maintenance on equipment were not developed and implemented. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2013-05-24 |
Abatement Due Date |
2013-05-31 |
Current Penalty |
2160.0 |
Initial Penalty |
3600.0 |
Final Order |
2013-06-19 |
Nr Instances |
5 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. (a) Canopy Department and Welding Department - on or about March 7, 2013, 3 stroke belt sanders located in the Canopy Departmentt and 2 stroke belt Sanders located in the Welding Department did not have idler wheel covers (guards). |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2013-05-24 |
Abatement Due Date |
2013-05-31 |
Current Penalty |
1620.0 |
Initial Penalty |
2700.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. (a) QC Test Panel - On or about March 7, 2013, the circuit breakers in electrical panel 31 were not labeled to indicate what each breaker controls. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100304 G05 |
Issuance Date |
2013-05-24 |
Abatement Due Date |
2013-05-24 |
Current Penalty |
1836.0 |
Initial Penalty |
3060.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective. (a) Welding Department - On or about March 7, 2013, the large commercial fan was not grounded. The power cord did not have a grounding prong. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 I |
Issuance Date |
2013-05-24 |
Abatement Due Date |
2013-05-24 |
Current Penalty |
1836.0 |
Initial Penalty |
3060.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. (a) Canopy Department - On or about March 7, 2013, the power cord for the Kuhlmeyer belt sander was not protected from abrasion and the opening where the power cord entered the electric motor was not closed. |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2013-05-24 |
Abatement Due Date |
2013-05-24 |
Current Penalty |
1836.0 |
Initial Penalty |
3060.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. (a) Maintenance Department - On or about March 6, 2013, circuit breaker number 28 was removed from the circuit breaker panel and the opening was not covered. The circuit breaker panel is located next to the roll-up door. |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2013-05-24 |
Abatement Due Date |
2013-05-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. (a). Model Department - On or about March 7, 2013, a knockout plug was missing from the electrical receptacle for the sander and punch press. The receptacle had an unused opening. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 |
Issuance Date |
2013-05-24 |
Abatement Due Date |
2013-06-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-06-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. (a). Welding Department - On or about March 6, 2013, the throw switch for the Millermatic 200 welder was blocked by empty compressed gas cylinders. |
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-07-12
|
Emphasis |
L: EISAOF, L: EISAX, L: FORKLIFT, N: AMPUTATE
|
Case Closed |
2012-08-30
|
Related Activity
Type |
Complaint |
Activity Nr |
440730 |
Safety |
Yes |
|
Type |
Referral |
Activity Nr |
450770 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2012-08-15 |
Abatement Due Date |
2012-08-17 |
Current Penalty |
2550.0 |
Initial Penalty |
4250.0 |
Final Order |
2012-09-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. a. Fabrication Department, 5601 Viking Road - On or about July 12, 2012 the interlock for the Salvagnini press brake door was bypassed and there was not a barrier in place to prevent the operator from placing his hands in the press danger zones. |
|
|