Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2013-11-07
|
Emphasis |
N: PMETALS, P: PMETALS
|
Case Closed |
2014-07-21
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-02-05 |
Current Penalty |
960.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rest(s) shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch: (a) Shop Area - On or about November 6, 2013 the work rest on the Baldor bench grinder was 2 inches from the wheel. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2014-01-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the wheel periphery(s) and the adjustable tongue or the end of the safety peripheral member at the top shall never exceed one-fourth inch: (a) Shop - On or about November 6, 2013 a Baldor bench grinder did not have a tongue guard. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2014-01-14 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. (a) North End of Shop - On or about November 6, 2013, the electrical box was not mounted. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 I |
Issuance Date |
2014-01-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidentalcontact by use of approved cabinets or other forms of approved enclosures or by any of the following means: (a) North End of Shop - On or about November 6, 2013 the electrical box did not have a faceplate. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-01-22 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident: (a) East Wall - On or about November 6, 2014 electrical breaker boxes were not labeled. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100303 G01 |
Issuance Date |
2014-01-14 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. (a) North End - On or about November 6, 2013 the electrical panel was blocked by the storage of supplies and parts. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100132 D02 |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-01-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. (a) Facility - On or abount November 6, 2013 the employer did not certify that a workplace hazard assessment had been performed. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-01-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: (a) Facility - On or about November 6, 2013 the employer had not developed and implemented a written hazard communication program for employees using chemicals, such as, propane, oxygen, etc. |
|
|