Name: | R H PLUMBING, INC. |
Jurisdiction: | MISSISSIPPI |
Business Type: | Profit Corporation |
Status: | Good Standing |
Effective Date: | 23 Dec 1991 (33 years ago) |
Business ID: | 584688 |
ZIP code: | 38801 |
County: | Lee |
State of Incorporation: | MISSISSIPPI |
Principal Office Address: | 2036 South Green StreetTupelo, MS 38801 |
Type | Company Name | Company Number | State |
---|---|---|---|
Headquarter of | R H PLUMBING, INC., ALABAMA | 000-030-826 | ALABAMA |
Name | Role | Address |
---|---|---|
RICHARD R HANLON | Agent | RR 2 BOX 2-C, OKOLONA, MS 38860 |
Name | Role | Address |
---|---|---|
Kenneth M Burns | Incorporator | 330 Main St, Okolona, MS 38860 |
Name | Role | Address |
---|---|---|
R H Plumbing Inc | President | 2036 South Green Street, Tupelo, MS 38801 |
Name | Role | Address |
---|---|---|
Helen Hanlon | Vice President | Post Offce Box 417, Okolona, MS 38860 |
Type | Status | Filed Date | Description |
---|---|---|---|
Annual Report | Filed | 2024-02-22 | Annual Report For R H PLUMBING, INC. |
Annual Report | Filed | 2023-03-13 | Annual Report For R H PLUMBING, INC. |
Annual Report | Filed | 2022-03-18 | Annual Report For R H PLUMBING, INC. |
Annual Report | Filed | 2021-03-05 | Annual Report For R H PLUMBING, INC. |
Annual Report | Filed | 2020-02-10 | Annual Report For R H PLUMBING, INC. |
Annual Report | Filed | 2019-03-13 | Annual Report For R H PLUMBING, INC. |
Annual Report | Filed | 2018-01-30 | Annual Report For R H PLUMBING, INC. |
Annual Report | Filed | 2017-01-26 | Annual Report For R H PLUMBING, INC. |
Annual Report | Filed | 2016-02-16 | Annual Report For R H PLUMBING, INC. |
Annual Report | Filed | 2015-06-23 | Annual Report For R H PLUMBING, INC. |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345016620 | 0419400 | 2020-11-04 | 1804 S. GREEN ST., TUPELO, MS, 38801 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1501723 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1502111 |
Safety | Yes |
Type | Accident |
Activity Nr | 1683239 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100147 C04 I |
Issuance Date | 2021-04-30 |
Abatement Due Date | 2021-05-24 |
Current Penalty | 13653.0 |
Initial Penalty | 13653.0 |
Final Order | 2021-05-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. a. Cooper Tire & Rubber Co., North Air Dryer - On or about November 4, 2020, the specific lockout procedures were not utilized prior to installing a valve on the intake header of the air dryer, exposing employees to a struck-by hazard. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100147 C07 I A |
Issuance Date | 2021-04-30 |
Abatement Due Date | 2021-05-24 |
Current Penalty | 6144.0 |
Initial Penalty | 6144.0 |
Final Order | 2021-05-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. (a) Cooper Tire & Rubber Co., North Air Dryer - On or about November 4, 2020, employees installing a valve on the intake header of the air dryer had not received authorized employee training, exposing employees to a struck-by hazard. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19100147 D03 |
Issuance Date | 2021-04-30 |
Abatement Due Date | 2021-05-24 |
Current Penalty | 8601.0 |
Initial Penalty | 8601.0 |
Final Order | 2021-05-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(d)(3): All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). a) Cooper Tire & Rubber Co. North Air Dryer - On or about November 4, 2020, employees installing a valve on the intake header of the air dryer did not relieve the header air pressure before attempting to remove the coupler and flange, exposing employees to a struck-by hazard. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19100147 D04 I |
Issuance Date | 2021-04-30 |
Abatement Due Date | 2021-05-24 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-05-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. a) Cooper Tire & Rubber Co., North Air Dryer, - On or about November 4, 2020, employees installing a valve on the intake header of the air dryer did not place locks on the air dryer energy isolating devices, exposing employees to a struck-by hazard. |
Citation ID | 01003C |
Citaton Type | Serious |
Standard Cited | 19100147 D06 |
Issuance Date | 2021-04-30 |
Abatement Due Date | 2021-05-24 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-05-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(d)(6):Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee did not verify that isolation and de-energization of the machine or equipment had been accomplished. a) Cooper Tire & Rubber Co., North Air Dryer - On or about November 4, 2020, employees installing a valve on the intake header of the air dryer did not verify if the air dryer was depressurized before attempting to remove a coupler and flange from the intake header, exposing employees to a struck-by hazard. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100147 F02 I |
Issuance Date | 2021-04-30 |
Abatement Due Date | 2021-05-24 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-05-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(f)(2)(i):Whenever outside personnel were engaged in activities covered by the scope and application of this standard, the on-site employer and the outside employer did not inform each other of their respective lockout or tagout procedures: (a) Facility - On or about November 4, 2020, R H Plumbing, Inc. and Cooper Tire & Rubber Co. did not inform each of their respective lockout/tagout procedures prior to R H Plumbing employees working on the north air dryer. |
Inspection Type | Referral |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2020-06-19 |
Case Closed | 2020-06-20 |
Related Activity
Type | Referral |
Activity Nr | 1609904 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1480201 |
Safety | Yes |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2001-03-27 |
Emphasis | S: CONSTRUCTION |
Case Closed | 2001-04-30 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260404 B01 II |
Issuance Date | 2001-04-10 |
Abatement Due Date | 2001-04-13 |
Current Penalty | 250.0 |
Initial Penalty | 525.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 05 |
Date of last update: 14 Mar 2025
Sources: Mississippi Secretary of State