346467822
|
0419400
|
2023-01-25
|
1002 HUNT ST, PICAYUNE, MS, 39466
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2023-01-25
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2023-03-31
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2023-02-13 |
Abatement Due Date |
2023-03-08 |
Current Penalty |
3615.6 |
Initial Penalty |
6026.0 |
Final Order |
2023-02-27 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) Facility - On or about January 25, 2023, employees were exposed to corrosive material while connecting the forklift's battery to the charging station without the use of an adequate eye wash station. |
|
|
343625828
|
0419400
|
2018-11-28
|
1002 HUNT STREET, PICAYUNE, MS, 39466
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-11-28
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2019-04-30
|
Related Activity
Type |
Referral |
Activity Nr |
1402953 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I A |
Issuance Date |
2019-04-03 |
Abatement Due Date |
2019-04-11 |
Current Penalty |
13260.0 |
Initial Penalty |
13260.0 |
Final Order |
2019-04-30 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: (a) North building - On or about November 28, 2018 the employer had not performed adequate training for employees who are authorized to perform energy control procedures exposing employees to amputation hazards from energy sources such as but not limited to electrical and kinetic energy while performing tasks including but not limited to start-up, maintenance, servicing, and jam clearing of the Farrell Compound Mixer. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I B |
Issuance Date |
2019-04-03 |
Abatement Due Date |
2019-04-11 |
Current Penalty |
13260.0 |
Initial Penalty |
0.0 |
Final Order |
2019-04-30 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: (a) North building - On or about November 28, 2018 the employer had not performed adequate training for employees who are affected when energy control procedures are applied to the Farrell Compound Mixer exposing employees to amputation hazards from energy sources such as but not limited to electrical and kinetic energy while performing tasks including but not limited to start-up, maintenance, servicing, and jam clearing. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2019-04-03 |
Abatement Due Date |
2019-04-25 |
Current Penalty |
13260.0 |
Initial Penalty |
13260.0 |
Final Order |
2019-04-30 |
Nr Instances |
6 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) North building - On or about November 28, 2018 the employer did not provide guarding to prevent employees exposure to amputation hazards at the point of operation while they fed whip material into the Farrel Compound Mixer machines by hand to build up the AMPs. |
|
Citation ID |
02001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2019-04-03 |
Abatement Due Date |
2019-04-18 |
Current Penalty |
13260.0 |
Initial Penalty |
132598.0 |
Final Order |
2019-04-30 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) North building - On or before November 28, 2018 the employer did not develop, document and utilize procedures for energy control exposing employees to amputation hazards from energy sources such as but not limited to electrical and kinetic energy while performing tasks including but not limited to start-up, maintenance, servicing, and jam clearing of the Farrell Compound Mixer. |
|
Citation ID |
02001B |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2019-04-03 |
Abatement Due Date |
2019-04-18 |
Current Penalty |
13260.0 |
Initial Penalty |
0.0 |
Final Order |
2019-04-30 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. (a) North building - On or before November 28, 2018 the employer did not affix a lockout or tagout device exposing employees to amputation hazards from energy sources such as but not limited to electrical and kinetic energy while performing tasks including but not limited to start-up, maintenance, servicing, and jam clearing of the Farrell Compound Mixer. |
|
|
313634057
|
0419400
|
2010-11-02
|
1002 HUNT ST, PICAYUNE, MS, 39466
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2011-01-24
|
Case Closed |
2011-01-24
|
Related Activity
Type |
Complaint |
Activity Nr |
207972530 |
Safety |
Yes |
Health |
Yes |
|
|
302399613
|
0419400
|
2001-02-08
|
1002 HUNT ST, PICAYUNE, MS, 39466
|
|
Inspection Type |
Monitoring
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2001-02-08
|
Case Closed |
2001-02-08
|
Related Activity
Type |
Inspection |
Activity Nr |
302394564 |
|
|
302394564
|
0419400
|
1999-12-01
|
1002 HUNT ST, PICAYUNE, MS, 39466
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1999-12-01
|
Emphasis |
N: SSINTARG
|
Case Closed |
2001-04-19
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
1999-12-30 |
Abatement Due Date |
2001-04-01 |
Current Penalty |
830.0 |
Initial Penalty |
1575.0 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100023 D01 IV |
Issuance Date |
1999-12-30 |
Abatement Due Date |
2000-01-12 |
Current Penalty |
360.0 |
Initial Penalty |
675.0 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
1999-12-30 |
Abatement Due Date |
2000-01-06 |
Current Penalty |
450.0 |
Initial Penalty |
900.0 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
02 |
|
|
302394515
|
0419400
|
1999-12-01
|
1002 HUNT ST, PICAYUNE, MS, 39466
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
1999-12-01
|
Emphasis |
N: SSINTARG
|
Case Closed |
2000-01-26
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19101030 C01 I |
Issuance Date |
1999-12-30 |
Abatement Due Date |
2000-01-27 |
Current Penalty |
360.0 |
Initial Penalty |
675.0 |
Nr Instances |
1 |
Nr Exposed |
21 |
Gravity |
01 |
|
|
18136218
|
0419400
|
1992-12-17
|
1002 HUNT ST, PICAYUNE, MS, 39466
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
1992-12-17
|
Case Closed |
1993-02-11
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19040002 B02 |
Issuance Date |
1993-01-22 |
Abatement Due Date |
1993-01-27 |
Nr Instances |
1 |
Gravity |
00 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100022 D01 |
Issuance Date |
1993-01-22 |
Abatement Due Date |
1993-02-10 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
00 |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100147 C01 |
Issuance Date |
1993-01-22 |
Abatement Due Date |
1993-02-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
00 |
|
Citation ID |
01004 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
1993-01-22 |
Abatement Due Date |
1993-02-10 |
Nr Instances |
1 |
Nr Exposed |
36 |
Gravity |
00 |
|
Citation ID |
01005A |
Citaton Type |
Other |
Standard Cited |
19101200 F05 |
Issuance Date |
1993-01-22 |
Abatement Due Date |
1993-02-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
00 |
|
Citation ID |
01005B |
Citaton Type |
Other |
Standard Cited |
19101200 F05 II |
Issuance Date |
1993-01-22 |
Abatement Due Date |
1993-02-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
00 |
|
|