340808971
|
0419400
|
2015-07-21
|
1735 N. WASHINGTON ST., VICKSBURG, MS, 39183
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-07-21
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2015-07-30
|
Related Activity
Type |
Inspection |
Activity Nr |
1058735 |
Safety |
Yes |
|
|
340769595
|
0419400
|
2015-06-30
|
1735 N. WASHINGTON ST., VICKSBURG, MS, 39183
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-06-30
|
Case Closed |
2015-06-30
|
Related Activity
Type |
Complaint |
Activity Nr |
996003 |
Safety |
Yes |
|
|
340587351
|
0419400
|
2015-04-22
|
1735 N. WASHINGTON ST., VICKSBURG, MS, 39183
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-04-23
|
Emphasis |
L: FORKLIFT, N: AMPUTATE
|
Case Closed |
2015-07-16
|
Related Activity
Type |
Complaint |
Activity Nr |
977065 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2015-06-17 |
Abatement Due Date |
2015-07-31 |
Current Penalty |
3000.0 |
Initial Penalty |
3000.0 |
Final Order |
2015-07-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. (a) Press Department, Veneer Glue Spread Layup Operation, North End of Discharge Roller Conveyor - On or about April 22, 2015 employees were exposed to getting caught in/by the first two live, powered rolls which were about 4 feet wide and 3 feet above the floor due to the employee's inability to access an emergency stop cord. |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19100304 G06 VI C 5 |
Issuance Date |
2015-06-17 |
Abatement Due Date |
2015-06-19 |
Current Penalty |
0.0 |
Initial Penalty |
2250.0 |
Final Order |
2015-07-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(6)(vi)(C)(5): Exposed noncurrent-carrying metal parts of cord- and plug-connected equipment that could have become energized were not grounded under the following condition(s) listed in (C) of this paragraph, i.e., (5) cord- and plug-connected appliances used in damp or wet locations, or by employees standing on the ground or on metal floors or working inside of metal tanks or boilers: (a) Press Department, Veneer Glue Spread Layup Operation, Northwest Corner of Infeed Core-Stack Scissor Table - On or about April 22, 2015 employees were exposed to an ungrounded extension cord supplying power to one of two overhead pedestal fans via a yellow AWG 12/3 extension cord having a 3-way female end but which was missing the grounding prong at its male attachment plug. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2015-06-17 |
Abatement Due Date |
2015-06-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure. (a) Press Department, Veneer Glue Spread Layup Operation, Northwest Corner of Infeed Core-Stack Scissor Table - On or about April 22, 2015, employees were using extension cords as a substitute for fixed wiring due to the lack of a sufficient number of hard-wired outlets in the area. Extension cords were powering two overhead pedestal fans via an orange AWG 12/3 extension cord and a yellow AWG 12/3 extension cord. |
|
|
304316888
|
0419400
|
2003-01-09
|
1085 HIGHWAY 80 WEST, JACKSON, MS, 39204
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2003-01-27
|
Case Closed |
2003-01-27
|
Related Activity
Type |
Complaint |
Activity Nr |
204183644 |
Health |
Yes |
|
|
107092090
|
0419400
|
1997-09-23
|
1085 HIGHWAY 80 WEST, JACKSON, MS, 39206
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
1997-09-23
|
Case Closed |
1997-09-25
|
Related Activity
Type |
Complaint |
Activity Nr |
201349834 |
Health |
Yes |
|
|
301032769
|
0419400
|
1997-08-12
|
1085 HIGHWAY 80 WEST, JACKSON, MS, 39206
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
1997-08-27
|
Case Closed |
1997-09-30
|
Related Activity
Type |
Referral |
Activity Nr |
201360401 |
Safety |
Yes |
|
|
107094906
|
0419400
|
1996-09-16
|
1085 HIGHWAY 80 WEST, JACKSON, MS, 39206
|
|
Inspection Type |
Accident
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
1996-09-19
|
Case Closed |
1996-11-25
|
Related Activity
Type |
Accident |
Activity Nr |
101360121 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
1996-10-30 |
Abatement Due Date |
1996-12-02 |
Current Penalty |
1625.0 |
Initial Penalty |
1625.0 |
Nr Instances |
3 |
Nr Exposed |
10 |
Related Event Code (REC) |
Accident |
Gravity |
03 |
|
|
18134643
|
0419400
|
1993-02-08
|
1085 HIGHWAY 80 WEST, JACKSON, MS, 39206
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Health
|
Close Conference |
1993-02-08
|
Case Closed |
1993-02-08
|
|
101252179
|
0419400
|
1987-06-09
|
HWY. 80, JACKSON, MS, 39204
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
1987-06-09
|
Case Closed |
1987-06-19
|
Related Activity
Type |
Complaint |
Activity Nr |
71210793 |
Health |
Yes |
|
|
101632891
|
0419400
|
1987-02-10
|
HWY. 80, JACKSON, MS, 39204
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
1987-02-12
|
Case Closed |
1987-02-24
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19101200 G08 |
Issuance Date |
1987-02-18 |
Abatement Due Date |
1987-03-06 |
Nr Instances |
1 |
Nr Exposed |
10 |
|
|
13582341
|
0419400
|
1982-10-12
|
416 HWY 80 WEST, Jackson, MS, 39204
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1982-10-14 |
Case Closed |
1983-05-06 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 A08 |
Issuance Date |
1982-11-15 |
Abatement Due Date |
1982-11-30 |
Initial Penalty |
240.0 |
Contest Date |
1982-11-15 |
Nr Instances |
1 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100242 B |
Issuance Date |
1982-11-15 |
Abatement Due Date |
1982-11-30 |
Contest Date |
1982-11-15 |
Nr Instances |
1 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100243 C03 |
Issuance Date |
1982-11-15 |
Abatement Due Date |
1982-11-17 |
Contest Date |
1982-11-15 |
Nr Instances |
1 |
|
|