341443141
|
0419400
|
2016-04-29
|
101 E. VETERANS DRIVE, BOONEVILLE, MS, 38829
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-04-29
|
Case Closed |
2016-08-09
|
Related Activity
Type |
Inspection |
Activity Nr |
1110907 |
Safety |
Yes |
|
|
341109072
|
0419400
|
2015-12-08
|
101 E. VETERANS DRIVE, BOONEVILLE, MS, 38829
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-12-09
|
Emphasis |
L: FOODPRO, N: AMPUTATE
|
Case Closed |
2016-01-29
|
Related Activity
Type |
Referral |
Activity Nr |
1042538 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 B01 |
Issuance Date |
2016-01-08 |
Abatement Due Date |
2016-01-12 |
Current Penalty |
1530.0 |
Initial Penalty |
2550.0 |
Final Order |
2016-01-29 |
Nr Instances |
1 |
Nr Exposed |
100 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. (a) Footbath - On or about December 8, 2015 a drain located inside the footbath protruded upward from the floor and created a tripping hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II D |
Issuance Date |
2016-01-08 |
Abatement Due Date |
2016-01-26 |
Current Penalty |
2550.0 |
Initial Penalty |
4250.0 |
Final Order |
2016-01-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control. (a) Line 6 - On or about December 8, 2015 the 180 Formax meat slicer's interlock door could be opened while the blade was still turning. Employees were exposed to an amputation hazard. |
|
|
339061962
|
0419400
|
2013-05-02
|
100 PLUMROSE DRIVE, BOONEVILLE, MS, 38829
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-05-03
|
Emphasis |
L: FOODPRO, N: AMPUTATE, N: SSTARG12, P: SSTARG12
|
Case Closed |
2013-08-19
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2013-07-19 |
Current Penalty |
1326.0 |
Initial Penalty |
2550.0 |
Final Order |
2013-08-19 |
Nr Instances |
1 |
Nr Exposed |
14 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. (a) Vacuum Tunnel - On or about May 3, 2013 employees using an air hose provided in the basement for cleaning motors, pumps, etc. were exposed to an air embolism due to the connected unidentified brand silver air nozzle emitting compressed air at over 100 psig. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2013-07-19 |
Current Penalty |
1658.0 |
Initial Penalty |
3188.0 |
Final Order |
2013-08-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. (a) Electrical Room across hall from USDA Office - On or about 5/3/2013 employees were exposed to electrical shock due to the inability to identify or lockout the correct disconnect switch because the 480 VAC Allen-Bradley Centerline MCC Disconnect Switch at top in back corner of room was not labeled as to what it controlled. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100304 G06 VI C 5 |
Issuance Date |
2013-07-19 |
Current Penalty |
1658.0 |
Initial Penalty |
3188.0 |
Final Order |
2013-08-19 |
Nr Instances |
1 |
Nr Exposed |
14 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(6)(vi)(C)(5): Supports, enclosures, and equipment to be grounded. Exposed noncurrent-carrying metal parts of cord- and plug-connected equipment that may become energized shall be grounded under any of the following conditions: If the equipment is of the following types: Cord- and plug-connected appliances used in damp or wet locations, or by employees standing on the ground or on metal floors or working inside of metal tanks or boilers; (a) Vacuum Tunnel beneath Boxing Area of Plant - On or about May 3, 2013 employees were exposed to electrical shock due to the absence of a grounding prong on the cord/plug of a 38 inch diameter Dayton mobile fan being used for general ventilation in the tunnel. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2013-07-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. (a) North wall of Slicing Room, between Slicing Lines #4 & #5 - On or about 5/2/2013 employees were exposed to electrical shock due to missing strain-relief at the hard-wired, black, 4-wire current supply cord coming from the bottom of a Siemens side-throw Safety Switch and going to the Koch Dicer. The black, 4-conductor flexible electrical cord had pulled out of the yellow plastic strain-relief connector at bottom of the Siemens Safety Switch. |
|
|
311412993
|
0419400
|
2008-01-18
|
101 E. VETERANS DRIVE, BOONEVILLE, MS, 38829
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2008-01-24
|
Emphasis |
L: FOODPRO, N: SSTARG07, S: AMPUTATIONS, S: ELECTRICAL
|
Case Closed |
2008-02-26
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100219 C04 I |
Issuance Date |
2008-02-07 |
Abatement Due Date |
2008-02-12 |
Current Penalty |
740.0 |
Initial Penalty |
1300.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
|
306655978
|
0419400
|
2004-06-24
|
101 E. VETERANS DRIVE, BOONEVILLE, MS, 38829
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2004-07-01
|
Emphasis |
S: ERGONOMICS, N: AMPUTATE, L: FOODPRO, S: AMPUTATIONS
|
Case Closed |
2004-11-01
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100119 D02 IA |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Current Penalty |
500.0 |
Initial Penalty |
2625.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100119 E02 |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100119 E03 V |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100119 E03 II |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001E |
Citaton Type |
Serious |
Standard Cited |
19100119 E03 IV |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001F |
Citaton Type |
Serious |
Standard Cited |
19100119 E03 VI |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001G |
Citaton Type |
Serious |
Standard Cited |
19100119 E03 III |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001H |
Citaton Type |
Serious |
Standard Cited |
19100119 E03 III |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001I |
Citaton Type |
Serious |
Standard Cited |
19100119 E05 |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001J |
Citaton Type |
Serious |
Standard Cited |
19100119 E05 |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001K |
Citaton Type |
Serious |
Standard Cited |
19100119 E06 |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001L |
Citaton Type |
Serious |
Standard Cited |
19100119 F01 I |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001M |
Citaton Type |
Serious |
Standard Cited |
19100119 L01 |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01001N |
Citaton Type |
Serious |
Standard Cited |
19100119 O01 |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2004-09-03 |
Abatement Due Date |
2004-09-23 |
Current Penalty |
500.0 |
Initial Penalty |
1125.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|