Search icon

KWE, Inc.

Company Details

Name: KWE, Inc.
Jurisdiction: MISSISSIPPI
Business Type: Profit Corporation
Status: Dissolved
Effective Date: 22 Apr 1996 (29 years ago)
Business ID: 629303
ZIP code: 38829
County: Prentiss
State of Incorporation: MISSISSIPPI
Principal Office Address: 2011 N Second StreetBooneville, MS 38829
Historical names: EUBANK CONSTRUCTION CO. INC.

Agent

Name Role Address
Biz Agent, Inc. Agent 336 N. Green Street, P.O. Box 90 (38802), Tupelo, MS 38804

Incorporator

Name Role Address
Kimberly M. Eubank Incorporator 108 Carleigh Lane, Booneville, MS 38829
Kevin Eubank Incorporator 108 Carleigh Lane, Booneville, MS 38829

Director

Name Role Address
Kevin Eubank Director 2011 North Second Street, Booneville, MS 38829
Kimberly Eubank Director 2011 North Second Street, Booneville, MS 38829

President

Name Role Address
Kevin Eubank President 2011 North Second Street, Booneville, MS 38829

Vice President

Name Role Address
Charles Alan Thompson Vice President 2011 N 2nd Street, Booneville, MS 38829
Robert Rogers Vice President 2011 N 2nd Street, Booneville, MS 38829

Secretary

Name Role Address
Kimberly Eubank Secretary 2011 North Second Street, Booneville, MS 38829

Filings

Type Status Filed Date Description
Dissolution Filed 2023-07-24 Dissolution For KWE, Inc.
Annual Report Filed 2023-01-12 Annual Report For KWE, Inc.
Annual Report Filed 2022-01-17 Annual Report For KWE, Inc.
Annual Report Filed 2021-01-13 Annual Report For KWE, Inc.
Annual Report Filed 2020-08-21 Annual Report For KWE, Inc.
Amendment Form Filed 2019-11-07 Amendment For EUBANK CONSTRUCTION CO. INC.
Annual Report Filed 2019-01-25 Annual Report For EUBANK CONSTRUCTION CO. INC.
Annual Report Filed 2018-02-07 Annual Report For EUBANK CONSTRUCTION CO. INC.
Annual Report Filed 2017-03-22 Annual Report For EUBANK CONSTRUCTION CO. INC.
Annual Report Filed 2016-09-01 Annual Report For EUBANK CONSTRUCTION CO. INC.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340374388 0419400 2015-02-11 CR 219, BURNSVILLE, MS, 38833
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-02-11
Emphasis P: TRENCH, N: TRENCH
Case Closed 2015-03-30

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260651 C02
Issuance Date 2015-03-13
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2015-03-30
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees. (a) Jobsite - On or about February 11, 2015 employees worked the entire length of a trench 63 feet long x 5 feet 06 inch to 7 feet deep x 7 feet wide with vertical sides. The only egress was the 45 degree cut ramp on the east end.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260651 J02
Issuance Date 2015-03-13
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2015-03-30
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection by placing and keeping such materials or equipment at least 2 feet from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary was not provided. (a) Jobsite - On or about February 11, 2015 employees were exposed to a spoil pile that was positioned along the south wall of the trench.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260652 A01
Issuance Date 2015-03-13
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-03-30
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: (a) Jobsite - On or about February 11, 2015 employees working in an excavation that was greater than 5 feet deep. Employees working in type B soil were not protected from cave-in hazard by a trench shield protective system or sloping and benching system along the entire length of the trench.