Search icon

B-LINE FABRICATION COMPANY LLC

Company Details

Name: B-LINE FABRICATION COMPANY LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Good Standing
Effective Date: 22 Oct 1999 (26 years ago)
Business ID: 677677
ZIP code: 39503
County: Harrison
State of Incorporation: MISSISSIPPI
Principal Office Address: 13465 Oneal Rd, 13465 Oneal RdGulfport, MS 39503-5516

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
B-LINE FABRICATION COMPANY, LLC 401K PROFIT SHARING PLAN 2016 640869848 2017-12-15 B-LINE FABRICATION COMPANY, LLC 26
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1987-01-01
Business code 332900
Sponsor’s telephone number 2288323286
Plan sponsor’s address 13465 O'NEAL ROAD, GULFPORT, MS, 39503

Signature of

Role Plan administrator
Date 2017-12-15
Name of individual signing RAYBURN BROADUS JR
Valid signature Filed with authorized/valid electronic signature
B-LINE FABRICATION COMPANY, LLC 401K PROFIT SHARING PLAN 2016 640869848 2017-06-22 B-LINE FABRICATION COMPANY, LLC 23
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1987-01-01
Business code 332900
Sponsor’s telephone number 2288323286
Plan sponsor’s address 13465 O'NEAL ROAD, GULFPORT, MS, 39503

Signature of

Role Plan administrator
Date 2017-06-22
Name of individual signing RAY BROADUS JR
Valid signature Filed with authorized/valid electronic signature
Role Employer/plan sponsor
Date 2017-06-22
Name of individual signing RAY BROADUS JR
Valid signature Filed with authorized/valid electronic signature
B-LINE FABRICATION COMPANY, LLC 401K PROFIT SHARING PLAN 2015 640869848 2016-07-25 B-LINE FABRICATION COMPANY, LLC 26
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1987-01-01
Business code 332900
Sponsor’s telephone number 2288323286
Plan sponsor’s address 13465 O'NEAL ROAD, GULFPORT, MS, 39503

Signature of

Role Plan administrator
Date 2016-07-25
Name of individual signing RAY BROADUS JR
Valid signature Filed with authorized/valid electronic signature
Role Employer/plan sponsor
Date 2016-07-25
Name of individual signing RAY BROADUS JR
Valid signature Filed with authorized/valid electronic signature
B-LINE FABRICATION COMPANY, LLC 401K PROFIT SHARING PLAN 2014 640869848 2015-07-10 B-LINE FABRICATION COMPANY, LLC 31
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1987-01-01
Business code 332900
Sponsor’s telephone number 2288323286
Plan sponsor’s address 13465 O'NEAL ROAD, GULFPORT, MS, 39503

Signature of

Role Plan administrator
Date 2015-07-10
Name of individual signing RAY BROADUS JR
Valid signature Filed with authorized/valid electronic signature
B-LINE FABRICATION COMPANY, LLC 401(K) PROFIT SHA 2013 640869848 2014-08-25 B-LINE FABRICATION COMPANY, LLC 39
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1987-01-01
Business code 332900
Sponsor’s telephone number 2288323286
Plan sponsor’s address 13465 O'NEAL ROAD, GULFPORT, MS, 39503

Signature of

Role Plan administrator
Date 2014-08-25
Name of individual signing RAY BROADUS, JR
Valid signature Filed with authorized/valid electronic signature
B-LINE FABRICATION COMPANY, LLC 401(K) PROFIT SHA 2012 640869848 2013-03-29 B-LINE FABRICATION COMPANY, LLC 20
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1987-01-01
Business code 332900
Sponsor’s telephone number 2288323286
Plan sponsor’s address 13465 O'NEAL ROAD, GULFPORT, MS, 39503

Signature of

Role Plan administrator
Date 2013-03-29
Name of individual signing RAY BROADUS, JR
Valid signature Filed with authorized/valid electronic signature
B-LINE FABRICATION COMPANY, LLC 401(K) PROFIT SHA 2011 640869848 2012-06-19 B-LINE FABRICATION COMPANY, LLC 38
Three-digit plan number (PN) 001
Effective date of plan 1987-01-01
Business code 332900
Sponsor’s telephone number 2288323286
Plan sponsor’s address 13465 O'NEAL ROAD, GULFPORT, MS, 39503

Plan administrator’s name and address

Administrator’s EIN 640869848
Plan administrator’s name B-LINE FABRICATION COMPANY, LLC
Plan administrator’s address 13465 O'NEAL ROAD, GULFPORT, MS, 39503
Administrator’s telephone number 2288323286

Signature of

Role Plan administrator
Date 2012-06-19
Name of individual signing RAY BROADUS, JR
Valid signature Filed with authorized/valid electronic signature
B-LINE FABRICATION COMPANY, LLC 401(K) PROFIT SHA 2011 640869848 2012-07-12 B-LINE FABRICATION COMPANY, LLC 38
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1987-01-01
Business code 332900
Sponsor’s telephone number 2288323286
Plan sponsor’s address 13465 O'NEAL ROAD, GULFPORT, MS, 39503

Plan administrator’s name and address

Administrator’s EIN 640869848
Plan administrator’s name B-LINE FABRICATION COMPANY, LLC
Plan administrator’s address 13465 O'NEAL ROAD, GULFPORT, MS, 39503
Administrator’s telephone number 2288323286

Signature of

Role Plan administrator
Date 2012-07-12
Name of individual signing RAY BROADUS, JR
Valid signature Filed with authorized/valid electronic signature
B-LINE FABRICATION COMPANY, LLC 401K PROFIT SHARING PLAN 2010 640869848 2011-07-07 B-LINE FABRICATION COMPANY, LLC 38
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1987-01-01
Business code 332900
Sponsor’s telephone number 2288323286
Plan sponsor’s address 13465 ONEAL ROAD, GULFPORT, MS, 395035516

Plan administrator’s name and address

Administrator’s EIN 640869848
Plan administrator’s name B-LINE FABRICATION COMPANY, LLC
Plan administrator’s address 13465 ONEAL ROAD, GULFPORT, MS, 395035516
Administrator’s telephone number 2288323286

Signature of

Role Plan administrator
Date 2011-07-07
Name of individual signing LINDA BROADUS
Valid signature Filed with authorized/valid electronic signature
Role Employer/plan sponsor
Date 2011-07-07
Name of individual signing RAY BROADUS JR.
Valid signature Filed with incorrect/unrecognized electronic signature

Agent

Name Role Address
RAYBURN BROADUS Agent 13465 O, GULFPORT, MS 39503

Member

Name Role Address
Ray Broadus Jr Member 11421 Bethel Road, SAUCIER, MS 39574

Manager

Name Role Address
Jeremy Broadus Manager 18677 HWY. 67, BILOXI, MS 39532

Filings

Type Status Filed Date Description
Annual Report LLC Filed 2024-02-20 Annual Report For B-LINE FABRICATION COMPANY LLC
Annual Report LLC Filed 2023-01-31 Annual Report For B-LINE FABRICATION COMPANY LLC
Annual Report LLC Filed 2022-02-22 Annual Report For B-LINE FABRICATION COMPANY LLC
Annual Report LLC Filed 2021-01-28 Annual Report For B-LINE FABRICATION COMPANY LLC
Annual Report LLC Filed 2020-01-16 Annual Report For B-LINE FABRICATION COMPANY LLC
Annual Report LLC Filed 2019-04-10 Annual Report For B-LINE FABRICATION COMPANY LLC
Annual Report LLC Filed 2018-02-13 Annual Report For B-LINE FABRICATION COMPANY LLC
Annual Report LLC Filed 2017-01-31 Annual Report For B-LINE FABRICATION COMPANY LLC
Annual Report LLC Filed 2016-02-23 Annual Report For B-LINE FABRICATION COMPANY LLC
Annual Report LLC Filed 2015-03-09 Annual Report For B-LINE FABRICATION COMPANY LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344448741 0419400 2019-11-13 13465 ONEAL ROAD, GULFPORT, MS, 39503
Inspection Type Planned
Scope Partial
Safety/Health Health
Close Conference 2019-11-13
Emphasis L: HINOISE, P: HINOISE
Case Closed 2020-01-10

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100141 D02 II
Issuance Date 2019-12-17
Abatement Due Date 2020-01-10
Current Penalty 1363.8
Initial Penalty 2273.0
Final Order 2020-01-10
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: (a) On or about November 13,2019, The employer failed to provide the lavatory with cold and hot/tepid water exposing employees to ingestion of hazardous chemicals such as but not limited to slugger cutting fluid, diesel fuel #2, Shopcoat Primer, Red Oxide.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100141 D02 III
Issuance Date 2019-12-17
Abatement Due Date 2020-01-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-01-10
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(d)(2)(iii): Lavatories were not provided with hand soap or similar cleansing agent: On or about November 13, 2019, employees were not provided with hand soap or other cleansing agents thus exposing employees to chemical ingestion hazards from but not limited to slugger cutting fluid, diesel fuel #2, Shopcoat Primer, Red Oxide.
339792111 0419400 2014-06-05 13465 ONEAL ROAD, GULFPORT, MS, 39503
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2014-06-05
Emphasis L: SILICA, N: SILICA
Case Closed 2014-09-03

Related Activity

Type Inspection
Activity Nr 964280
Safety Yes
Type Referral
Activity Nr 892234
Health Yes
Type Inspection
Activity Nr 979952
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100134 C
Issuance Date 2014-07-22
Abatement Due Date 2014-08-08
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2014-08-18
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: (a) paint and sand blast area - On or about June 05, 2014 employees were using half face tight fitting respirators without a respiratory protection program.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100134 I07
Issuance Date 2014-07-22
Abatement Due Date 2014-08-15
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: (a) Air compressor shed - On or about June 05, 2014 employees were using a sand blasting hood with air supplied breathing air from air compressor that had a high temperature but the carbon monoxide levels were not monitored.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19101200 F05 I
Issuance Date 2014-07-22
Abatement Due Date 2014-08-01
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2014-08-18
Nr Instances 10
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: (a) Paint building - On or about June 05, 2014 employees were exposed to unlabeled containers.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19101200 F05 II
Issuance Date 2014-07-22
Abatement Due Date 2014-08-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-18
Nr Instances 10
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: (a) Paint area - On or about June 5, 2014 employees were exposed to chemicals such as thinners without the appropriate hazard warnings.
Citation ID 01004
Citaton Type Serious
Standard Cited 19101200 H03 IV
Issuance Date 2014-07-22
Abatement Due Date 2014-08-15
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2014-08-18
Nr Instances 20
Nr Exposed 20
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(3)(iv): The employer did not provide employees with effective information and training on hazardous chemicals in their work area. The training did not include an explanation of the labeling system and did not include an explanation of the safety data sheets, including the order of information and how employees could obtain and use the appropriate hazard information: (a) Site wide - On or about June 05, 2014 employees were working with and around hazardous chemicals and had not been provided training on safety data sheets and the labeling system.
339642803 0419400 2014-03-20 13465 ONEAL ROAD, GULFPORT, MS, 39503
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-03-20
Emphasis L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
Case Closed 2014-09-03

Related Activity

Type Referral
Activity Nr 892234
Health Yes
Type Inspection
Activity Nr 979211
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2014-07-22
Abatement Due Date 2014-08-01
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire hazards and hazardous chemicals. (a) Paint shed - On or about March 20, 2014, a siphon hose was used to transfer flammable solvent, RSC 1020 thinner, from a 55 gallon drum into 5 gallon buckets.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100106 E02 II
Issuance Date 2014-07-22
Abatement Due Date 2014-08-01
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(e)(2)(ii): Flammable or combustible liquids were not stored in tanks or closed containers: (a) In the shop - On or about March 20, 2014, solvent was stored in open top 5 gallon containers.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100106 E06 II
Issuance Date 2014-07-22
Abatement Due Date 2014-08-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and containers being electrically interconnected. (a) In paint shed - On or about March 20, 2014, RSC 1020 thinner was being transferred from 55 gallon containers into 5 gallon buckets without being grounded and bonded to each other.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100132 A
Issuance Date 2014-07-22
Abatement Due Date 2014-08-01
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a) In the shop - On or about March 20, 2014, an employee was exposed to fall hazards while operating a fork truck without wearing a seat belt.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100147 C04 II
Issuance Date 2014-07-22
Abatement Due Date 2014-08-15
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 20
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) In the shop - On or about March 20, 2014, there were no specific energy control procedures for the press brake, roll former, angle cutter, iron worker, air compressor, or other equipment requiring specific procedures.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2014-07-22
Abatement Due Date 2014-08-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 20
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) In the shop - On or about March 20, 2014, annual inspection of energy control procedures had not been performed for the press brake, roll former, angle cutter, iron worker, air compressor, or other equipment requiring specific procedures.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19100147 C06 II
Issuance Date 2014-07-22
Abatement Due Date 2014-08-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 20
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) In the shop - On or about March 20, 2014, there were no certified inspection records identifying who performed the lockout, date, and who conducted the inspection for the press brake, roll former, angle cutter, iron worker, air compressor, or other equipment requiring specific procedures.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100176 C
Issuance Date 2014-07-22
Abatement Due Date 2014-08-08
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.176(c): Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage: (a) In the paint shed - On or about March 20, 2014, closed and opened containers of cured and uncured paints or solvents were left to accumulate along a wall creating hazards of tripping, fires, explosion or pest harborage.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19100212 A
Issuance Date 2014-07-22
Abatement Due Date 2014-08-08
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-08-18
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Geka iron worker - On or about March 20, 2014, the foot control device was not protected from objects falling onto it and causing the machine to operate while employees were near the point of operation. b) Peddinghaus angle cutting - On or about March 20, 2014, the point of operation was not guarded when running 3 inch parts.
Citation ID 01006B
Citaton Type Serious
Standard Cited 19100212 A03 IV D
Issuance Date 2014-07-22
Abatement Due Date 2014-08-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(iv)(d): One or more methods of machine guarding were not provided to protect the operator and other employees in the press brake area of operation (front and back) from hazards such as those created at the point of operation, and ingoing nip points : (a) Press brake - On or about March 20, 2014, the press brake was not guarded to prevent or stop the machine when someone placed their hands near the point of operation.
Citation ID 02001
Citaton Type Other
Standard Cited 19100178 P01
Issuance Date 2014-07-22
Abatement Due Date 2014-08-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s); a) In the shop - On or about March 20, 2014, employees were exposed to struck-by hazards because the horn was defective on the Hyster fork truck.
Citation ID 02002
Citaton Type Other
Standard Cited 19100179 J02 III
Issuance Date 2014-07-22
Abatement Due Date 2014-08-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.179(j)(2)(iii): A certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, was not maintained: (a) DeShazo 5-Ton overhead crane - On or about March 20, 2014, there were no monthly certification inspection records of the overhead crane hooks with the date, signature, and identifier of the hooks.
Citation ID 02003
Citaton Type Other
Standard Cited 19100179 M01
Issuance Date 2014-07-22
Abatement Due Date 2014-08-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.179(m)(1): A certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier for the ropes which were inspected were not being kept on file where readily available to appointed personnel: (a) DeShazo 5-Ton overhead crane - On or about March 20, 2014, there were no monthly certification inspection records of the overhead crane ropes with the date, signature, and identifier of the rope (cable).
Citation ID 02004
Citaton Type Other
Standard Cited 19100253 B04 III
Issuance Date 2014-07-22
Abatement Due Date 2014-08-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-18
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) Outside of the building - On or about March 20, 2014, an oxygen cylinder was 11 feet 4 inches from fuel gases.

Date of last update: 18 Mar 2025

Sources: Mississippi Secretary of State