339749723
|
0419400
|
2014-04-24
|
301 W. SUNFLOWER, RULEVILLE, MS, 38771
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-04-24
|
Emphasis |
L: FORKLIFT, P: AMPUTATE, N: AMPUTATE
|
Case Closed |
2014-06-02
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2014-05-07 |
Abatement Due Date |
2014-05-15 |
Current Penalty |
2000.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-06-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Final Inspection Area - On or about April 24, 2014 the baler in the final inspection area was not guarded to prevent employees from accidentally getting part of the body in the point of operation. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2014-05-07 |
Abatement Due Date |
2014-06-03 |
Current Penalty |
1300.0 |
Initial Penalty |
2100.0 |
Final Order |
2014-06-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Jobsite - On or about April 24, 2014 unused openings in 220 volt electrical circuit panel box were not effectively closed. Employees were exposed to contacting live electric parts. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100333 B02 |
Issuance Date |
2014-05-07 |
Abatement Due Date |
2014-06-03 |
Current Penalty |
0.0 |
Initial Penalty |
3500.0 |
Final Order |
2014-06-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were de-energized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2): (a) Jobsite - On or about April 24, 2014 employees were performing electrical installations and the equipment was not locked out or tagged to prevent accidental re-energization. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100333 B02 I |
Issuance Date |
2014-05-07 |
Abatement Due Date |
2014-06-03 |
Current Penalty |
2000.0 |
Initial Penalty |
0.0 |
Final Order |
2014-06-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.333(b)(2)(i): The employer did not make a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 available for inspection by employees and by the Assistant Secretary of Labor and his or her authorized representatives: (a) Jobsite - On or about April 24, 2014, employees were performing electrical installations and repairs and the employer did not have a copy of the written lockout and tagout procedures. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040032 B02 II |
Issuance Date |
2014-05-07 |
Abatement Due Date |
2014-06-03 |
Current Penalty |
233.0 |
Initial Penalty |
700.0 |
Final Order |
2014-06-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.32(b)(2)(ii): 29 CFR 1904.32(b)(2)(ii): The employer did not enter the calendar year covered, the company's name, establishment name, establishment address, annual average number of employees covered by the OSHA 300 Log, and the total hours worked by all employees covered by the OSHA 300 Log. (a) Jobsite - On or about April 24, 2014 the 2013 OSHA 300A did not include the correct calendar year, column J was incorrect and the total hours worked by all employees was not provided. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19040032 B03 |
Issuance Date |
2014-05-07 |
Abatement Due Date |
2014-06-03 |
Current Penalty |
233.0 |
Initial Penalty |
700.0 |
Final Order |
2014-06-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.32(b)(3): 29 CFR 1904.32(b)(3): The Summary of Work-Related Injury and Illnesses (OSHA Form 300A or equivalent) was not properly certified: (a) Jobsite - On or about April 24, 2014 the OSHA 300A Annual Summary of Work-Related Injuries and Illnesses was not certified by a company executive. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19040032 B05 |
Issuance Date |
2014-05-07 |
Abatement Due Date |
2014-06-03 |
Current Penalty |
234.0 |
Initial Penalty |
700.0 |
Final Order |
2014-06-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.32(b)(5): A copy of the annual summary of work-related injuries and illnesses was not posted. (a) Jobsite - On or about April 24, 2014 a copy of the 2013 OSHA 300A Annual Summary of Work-Related Injuries and Illnesses was not posted in the workplace. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100132 D02 |
Issuance Date |
2014-05-07 |
Abatement Due Date |
2014-06-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-06-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment had been performed through a written certification that identified the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and which identifies the document as a certification of hazard assessment: (a) Jobsite - On or about April 24, 2014 the employer did not have documentation to certify a hazard assessment of the workplace has been conducted. |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19100134 C |
Issuance Date |
2014-05-07 |
Abatement Due Date |
2014-06-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-06-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: (a) Jobsite - On or about April 24, 2014 the employer was requiring employees to use respirators and had not implemented a written respiratory protection program. |
|
Citation ID |
02006 |
Citaton Type |
Other |
Standard Cited |
19100178 P01 |
Issuance Date |
2014-05-07 |
Abatement Due Date |
2014-06-03 |
Current Penalty |
700.0 |
Initial Penalty |
700.0 |
Final Order |
2014-06-02 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) (a) Jobsite - On or about April 24, 2014 employees were using forklifts that were in need of repair in that: (1) Hyster 8869 did not have an operable horn or backup alarm (2) TCM 519 did not have an operable lights or backup alarm |
|
|
313626251
|
0419400
|
2009-08-27
|
4410 HIGHWAY 49 WEST, DREW, MS, 38737
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2009-08-27
|
Emphasis |
L: SCRAPMTL
|
Case Closed |
2009-10-28
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A02 |
Issuance Date |
2009-10-02 |
Abatement Due Date |
2009-10-29 |
Current Penalty |
525.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2009-10-02 |
Abatement Due Date |
2009-10-29 |
Current Penalty |
525.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2009-10-02 |
Abatement Due Date |
2009-10-29 |
Current Penalty |
525.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|
311421374
|
0419400
|
2009-08-21
|
301 W. SUNFLOWER, RULEVILLE, MS, 38771
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2009-10-06
|
Emphasis |
L: SCRAPMTL
|
Case Closed |
2010-01-08
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2009-11-19 |
Abatement Due Date |
2009-12-16 |
Current Penalty |
525.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100141 D02 II |
Issuance Date |
2009-11-19 |
Abatement Due Date |
2009-12-16 |
Current Penalty |
525.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100141 D02 IV |
Issuance Date |
2009-11-19 |
Abatement Due Date |
2009-12-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100303 B07 I |
Issuance Date |
2009-11-19 |
Abatement Due Date |
2009-11-24 |
Current Penalty |
446.0 |
Initial Penalty |
446.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 |
Issuance Date |
2009-11-19 |
Abatement Due Date |
2009-12-16 |
Current Penalty |
875.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
|
308767243
|
0419400
|
2005-05-17
|
301 WEST SUNFLOWER STREET, RULEVILLE, MS, 38771
|
|
Inspection Type |
Monitoring
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2005-05-17
|
Case Closed |
2005-05-17
|
Related Activity
Type |
Inspection |
Activity Nr |
306657669 |
|
|
306657669
|
0419400
|
2004-11-30
|
301 WEST SUNFLOWER STREET, RULEVILLE, MS, 38771
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2004-12-01
|
Case Closed |
2005-07-13
|
Related Activity
Type |
Complaint |
Activity Nr |
204188395 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19101000 C |
Issuance Date |
2005-01-10 |
Abatement Due Date |
2005-06-30 |
Current Penalty |
1200.0 |
Initial Penalty |
2100.0 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
05 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19101000 E |
Issuance Date |
2005-01-10 |
Abatement Due Date |
2005-03-15 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
01 |
|
|
306656455
|
0419400
|
2004-07-13
|
4410 HIGHWAY 49 WEST, DREW, MS, 38737
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2004-07-14
|
Case Closed |
2005-03-11
|
Related Activity
Type |
Complaint |
Activity Nr |
204187413 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100141 A03 I |
Issuance Date |
2004-07-29 |
Abatement Due Date |
2004-08-10 |
Current Penalty |
675.0 |
Initial Penalty |
675.0 |
Nr Instances |
1 |
Nr Exposed |
11 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100141 A05 |
Issuance Date |
2004-07-29 |
Abatement Due Date |
2004-08-24 |
Nr Instances |
2 |
Nr Exposed |
21 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A05 |
Issuance Date |
2004-07-29 |
Abatement Due Date |
2004-08-10 |
Current Penalty |
675.0 |
Initial Penalty |
675.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100219 E01 I |
Issuance Date |
2004-07-29 |
Abatement Due Date |
2004-08-10 |
Current Penalty |
675.0 |
Initial Penalty |
675.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19101200 H |
Issuance Date |
2004-07-29 |
Abatement Due Date |
2004-08-24 |
Current Penalty |
675.0 |
Initial Penalty |
675.0 |
Nr Instances |
15 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100037 B02 |
Issuance Date |
2004-07-29 |
Abatement Due Date |
2004-08-17 |
Nr Instances |
1 |
Nr Exposed |
21 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
|
304315559
|
0419400
|
2002-10-02
|
301 W. SUNFLOWER, RULEVILLE, MS, 38771
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2002-10-22
|
Case Closed |
2003-06-13
|
Related Activity
Type |
Inspection |
Activity Nr |
304312838 |
|
|
304313588
|
0419400
|
2002-04-03
|
301 W. SUNFLOWER, RULEVILLE, MS, 38771
|
|
Inspection Type |
Monitoring
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2002-04-03
|
Case Closed |
2002-04-04
|
Related Activity
Type |
Inspection |
Activity Nr |
304312333 |
|
|
304312838
|
0419400
|
2002-02-07
|
301 W. SUNFLOWER, RULEVILLE, MS, 38771
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2002-03-22
|
Case Closed |
2003-10-29
|
Related Activity
Type |
Complaint |
Activity Nr |
202971990 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100134 B01 |
Issuance Date |
2002-03-26 |
Abatement Due Date |
2002-04-19 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19101000 A02 |
Issuance Date |
2002-03-26 |
Abatement Due Date |
2003-07-31 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
FTA Inspection NR |
304315559 |
FTA Issuance Date |
2002-10-23 |
FTA Current Penalty |
600.0 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19101000 E |
Issuance Date |
2002-03-26 |
Abatement Due Date |
2003-07-31 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
FTA Inspection NR |
304315559 |
FTA Issuance Date |
2002-10-23 |
FTA Current Penalty |
600.0 |
|
|
304312333
|
0419400
|
2002-01-10
|
301 W. SUNFLOWER, RULEVILLE, MS, 38771
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2002-01-18
|
Case Closed |
2002-04-26
|
Related Activity
Type |
Complaint |
Activity Nr |
202971677 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 II |
Issuance Date |
2002-03-04 |
Abatement Due Date |
2002-03-21 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100134 K06 |
Issuance Date |
2002-03-04 |
Abatement Due Date |
2002-03-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
|