341546299
|
0419400
|
2016-05-31
|
108 MORRIS TULLOS DRIVE, MORTON, MS, 39117
|
|
Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2016-08-30
|
Emphasis |
L: POULTRY4
|
Case Closed |
2016-09-19
|
Related Activity
Type |
Referral |
Activity Nr |
1080201 |
Safety |
Yes |
|
|
341439727
|
0419400
|
2016-04-28
|
921 SOUTH MAIN STREET, FOREST, MS, 39074
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-10-20
|
Emphasis |
L: FOODPRO, P: FOODPRO
|
Case Closed |
2016-11-04
|
Related Activity
Type |
Complaint |
Activity Nr |
1084840 |
Safety |
Yes |
Health |
Yes |
|
Type |
Complaint |
Activity Nr |
1103221 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2016-10-20 |
Abatement Due Date |
2016-11-14 |
Current Penalty |
2453.4 |
Initial Penalty |
4089.0 |
Final Order |
2016-11-03 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and with no obstructions: (a) Marination Area - On or about June 24, 2016, five 6 inch vacuum hoses were extending across the floor in the workarea creating a fall or trip hazard for employees walking/working in the area. |
|
|
341394625
|
0419400
|
2016-04-12
|
108 MORRIS TULLOS DRIVE, MORTON, MS, 39117
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-08-30
|
Emphasis |
L: POULTRY4, N: AMPUTATE, N: CHEMNEP
|
Case Closed |
2021-08-09
|
Related Activity
Type |
Referral |
Activity Nr |
1080201 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2016-09-16 |
Abatement Due Date |
2016-09-21 |
Current Penalty |
10000.0 |
Initial Penalty |
12471.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. (a) Production Area, Gizzard Chiller - On or about April 12, 2016 an employee using a high pressure hose to unjamming gizzards inside the gizzard chiller was struck by paddle on the hand when another employee turned machine on. The employee right middle finger and ring finger was broken. Lockout device was not affixed to gizzard chiller. |
|
|
341334423
|
0419400
|
2016-03-18
|
108 MORRIS TULLOS DRIVE, MORTON, MS, 39117
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-08-30
|
Emphasis |
L: FOODPRO, L: POULTRY4, N: AMPUTATE, N: CHEMNEP
|
Case Closed |
2021-08-09
|
Related Activity
Type |
Referral |
Activity Nr |
1071761 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2016-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
6057.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): Public Law 91-596, the Occupational Safety and Health Act of 1970, Section 5(a)(1): The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or are likely to cause death or serious physical harm to his employees, in that employees were exposed to a struck by hazard as a result of missing latch and load rating on a chain hoist. (a) Offal - On or about June 1, 2016, a chain hoist used to pull 150 pound filters out of the filter tank lacked a safety latch installed on the hook and a legible label exposing employees to a struck by hazard. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100022 C |
Issuance Date |
2016-09-16 |
Abatement Due Date |
2016-09-26 |
Current Penalty |
3000.0 |
Initial Penalty |
10689.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc. (a) Evisceration - On or about June 1, 2016, the employer lack covers over open drains thereby exposing backup gut pullers, sanitation employees and other employees working in evisceration to slip, trip and fall hazards. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100023 C03 |
Issuance Date |
2016-09-16 |
Abatement Due Date |
2016-10-11 |
Current Penalty |
10000.0 |
Initial Penalty |
12471.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board. (a) Evisceration 1st Processing - On or about June 8, 2016, an employee was observed hooking and unhooking his lanyard to traverse and clean the drip pans thereby being exposed to a 10 foot fall hazard. |
|
Citation ID |
01004A |
Citaton Type |
Other |
Standard Cited |
19100023 D01 |
Issuance Date |
2016-09-16 |
Current Penalty |
3000.0 |
Initial Penalty |
9086.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
30 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(d)(1): Flights of stairs having four or more risers were not equipped with a standard railing as specified in paragraphs (d)(1)(i) through (v) of this section: (a) Outside Shipping Department - On or about June 1, 2016, the stairway leading to shipping department lacked mid rails exposing employees to a fall hazard. |
|
Citation ID |
01004B |
Citaton Type |
Other |
Standard Cited |
19100024 H |
Issuance Date |
2016-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: (a) On or about June 1, 2016 fixed industrial stairs giving access to the waste water tank lacked a mid rail on one open side exposing employees and contractors to a fall hazard. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100146 C05 II B |
Issuance Date |
2016-09-16 |
Current Penalty |
7572.0 |
Initial Penalty |
7572.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
2 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(5)(ii)(B): When an entrance cover was removed, the opening was not promptly guarded by a railing, temporary cover, or other temporary barrier that would prevent an accidental fall through the opening and that would protect each employee (a) Bone Yard and Near Shipping Office - On or about June 1, 2016 employees were not protected from falling into open storm drains when using hoisting equipment to fish for and hoist pumps hoisted from the storm drains. Employees are exposed to 12-18 foot fall hazard. (b) Behind Waste Water Treatment - On or about June 1, 2016, employees were not protected from falling into an open pit when using hoisting equipment to fish for and hoist pumps from the pit. Employees are exposed to a 14 foot fall hazard. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100243 C01 |
Issuance Date |
2016-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
7126.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
22 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4) (a) Maintenance - On or about June 1, 2016 a grinder used by maintenance employees to grind on sheet metal lacked a guard exposing employees to the hazard of being struck by metal projectiles. |
|
Citation ID |
01007A |
Citaton Type |
Other |
Standard Cited |
19100219 C04 I |
Issuance Date |
2016-09-16 |
Abatement Due Date |
2016-09-26 |
Current Penalty |
3000.0 |
Initial Penalty |
10689.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) Offall - On or about June 1, 2016, the rotating shalt on the 2nd feather screw conveyor lacked a guard exposing employees assessing the stairway to the hazard of coming in contact with a rotating part. |
|
Citation ID |
01007B |
Citaton Type |
Other |
Standard Cited |
19100219 C04 II |
Issuance Date |
2016-09-16 |
Abatement Due Date |
2016-09-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: (a) Paw Chiller - On or about June 1, 2016 a keyway on a rotating shaft was not guarded exposing employees to the hazard of being struck-by or caught-in rotating part. |
|
Citation ID |
01008A |
Citaton Type |
Serious |
Standard Cited |
19100303 B06 |
Issuance Date |
2016-09-16 |
Abatement Due Date |
2016-09-26 |
Current Penalty |
10000.0 |
Initial Penalty |
12471.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(6): Unless identified for use in the operating environment, conductors or equipment were located in damp or wet locations; where exposed to gases, fumes, vapors, liquids, or other agents that had a deteriorating effect on the conductors or equipment; or where exposed to excessive temperatures: (a) Chemical Room - On or about June 8, 2016, employees were exposed to coming in contact with an electrical source because corrosive chemical from the central dispensing system located just above an electrical outlet had leaked onto the outlet and corroded the outlet and conduit. The employer had placed a plastic bag over the electrical outlet. |
|
Citation ID |
01008B |
Citaton Type |
Serious |
Standard Cited |
19100305 E01 |
Issuance Date |
2016-09-16 |
Abatement Due Date |
2016-09-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-10-07 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures: (a) Chemical Room - On or about June 8, 2016, employees were exposed to the hazard or contacting an energized source due to an electrical outlet being installed directly beneath the chemical central dispensing system. Corrosive chemical had leaked on and corroded the outlet and conduit. |
|
|
341153211
|
0419400
|
2016-01-04
|
410 KOCH DRIVE SUITE 100, MORTON, MS, 39117
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-01-05
|
Emphasis |
L: FOODPRO, L: POULTRY4, N: AMPUTATE, N: POULTRY
|
Case Closed |
2016-01-26
|
Related Activity
Type |
Referral |
Activity Nr |
1049305 |
Safety |
Yes |
|
|
340980721
|
0419400
|
2015-10-20
|
921 SOUTH MAIN STREET, FOREST, MS, 39074
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-10-20
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2016-01-08
|
Related Activity
Type |
Referral |
Activity Nr |
1028241 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 O01 |
Issuance Date |
2015-11-18 |
Abatement Due Date |
2015-12-04 |
Current Penalty |
4200.0 |
Initial Penalty |
7000.0 |
Final Order |
2016-01-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(o)(1): Load(s) on powered industrial truck(s) were not stable or safely arranged: a. Maintenance - On or about October 13, 2015 a forklift was used to lift a pallet jack for a drive wheel replacement. The pallet jack fell off the forklift and struck an employee. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2015-11-18 |
Abatement Due Date |
2015-11-27 |
Current Penalty |
600.0 |
Initial Penalty |
1000.0 |
Final Order |
2016-01-15 |
Nr Instances |
1 |
Nr Exposed |
608 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours. a. Koch Foods of Mississippi, LLC - On or about October 7, 2015 a maintenance employee was hospitalized due to a job related injury. The hospitalization was not reported to OSHA within 24 hours. |
|
|
340660323
|
0419400
|
2015-05-19
|
108 MORRIS TULLOS DRIVE, MORTON, MS, 39117
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-05-20
|
Case Closed |
2015-06-26
|
Related Activity
Type |
Complaint |
Activity Nr |
983579 |
Health |
Yes |
|
|
315308049
|
0419400
|
2012-03-20
|
108 MORRIS TULLOS DRIVE, MORTON, MS, 39117
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-03-22
|
Emphasis |
N: SSTARG11, S: AMPUTATIONS, N: POULTRY, N: PSMPQV, L: FOODPRO, L: FORKLIFT, S: STRUCK-BY, S: POWERED IND VEHICLE, S: NOISE, S: ELECTRICAL
|
Case Closed |
2012-07-23
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A02 |
Issuance Date |
2012-06-14 |
Abatement Due Date |
2012-07-31 |
Current Penalty |
1238.0 |
Initial Penalty |
2250.0 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2012-06-14 |
Abatement Due Date |
2012-06-19 |
Current Penalty |
1762.0 |
Initial Penalty |
3187.0 |
Nr Instances |
2 |
Nr Exposed |
6 |
Gravity |
05 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2012-06-14 |
Abatement Due Date |
2012-06-19 |
Current Penalty |
1762.0 |
Initial Penalty |
3187.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
05 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 III |
Issuance Date |
2012-06-14 |
Abatement Due Date |
2012-06-20 |
Current Penalty |
1238.0 |
Initial Penalty |
2250.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2012-06-14 |
Abatement Due Date |
2012-06-19 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
01 |
|
|
313635641
|
0419400
|
2011-01-26
|
5919 HIGHWAY 80 EAST, MORTON, MS, 39117
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-03-08
|
Case Closed |
2011-03-08
|
Related Activity
Type |
Complaint |
Activity Nr |
208142463 |
Safety |
Yes |
Health |
Yes |
|
|
313631087
|
0419400
|
2010-05-04
|
4688 HIGHWAY 80 EAST, MORTON, MS, 39117
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2010-05-05
|
Emphasis |
S: ELECTRICAL, S: HISPANIC, S: STRUCK-BY, S: NOISE, L: FOODPRO, S: POWERED IND VEHICLE
|
Case Closed |
2010-06-18
|
Related Activity
Type |
Complaint |
Activity Nr |
207562232 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 F03 II |
Issuance Date |
2010-05-12 |
Abatement Due Date |
2010-05-17 |
Current Penalty |
930.0 |
Initial Penalty |
1500.0 |
Nr Instances |
12 |
Nr Exposed |
12 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 I |
Issuance Date |
2010-05-12 |
Abatement Due Date |
2010-05-17 |
Current Penalty |
1170.0 |
Initial Penalty |
1875.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
|
306652553
|
0419400
|
2003-12-23
|
4688 HIGHWAY 80 EAST, MORTON, MS, 39117
|
|
Inspection Type |
Monitoring |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2003-12-23 |
Case Closed |
2003-12-30 |
Related Activity
Type |
Inspection |
Activity Nr |
306651167 |
|
|
306651167
|
0419400
|
2003-08-15
|
4688 HIGHWAY 80 EAST, MORTON, MS, 39117
|
|
Inspection Type |
Complaint |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2003-08-18 |
Emphasis |
S: FOOD PROCESSING |
Case Closed |
2004-02-26 |
Related Activity
Type |
Complaint |
Activity Nr |
204185110 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 IIB |
Issuance Date |
2003-10-09 |
Abatement Due Date |
2004-02-15 |
Current Penalty |
2275.0 |
Initial Penalty |
2275.0 |
Nr Instances |
20 |
Nr Exposed |
43 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2003-10-09 |
Abatement Due Date |
2003-11-05 |
Current Penalty |
1300.0 |
Initial Penalty |
1300.0 |
Nr Instances |
1 |
Nr Exposed |
18 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100219 C02 I |
Issuance Date |
2003-10-09 |
Abatement Due Date |
2003-11-05 |
Current Penalty |
1300.0 |
Initial Penalty |
1300.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
|
|