Search icon

UNIPRES SOUTHEAST U.S.A., INC.

Company Details

Name: UNIPRES SOUTHEAST U.S.A., INC.
Jurisdiction: MISSISSIPPI
Business Type: Profit Corporation
Status: Good Standing
Effective Date: 10 Jan 2002 (23 years ago)
Business ID: 711582
ZIP code: 39074
County: Scott
State of Incorporation: MISSISSIPPI
Principal Office Address: 1001 Fountain Drive, 1001 Fountain DriveForest, MS 39074

Agent

Name Role Address
Dheenadayalan, Balaji Agent 1001 Fountain Road, Forest, MS 39074

Incorporator

Name Role Address
Michihiko Nakazato Incorporator 201 Kirby Dr, Portland, TN 37148
Sadao Haga Incorporator 201 Kirby Dr, Portland, TN 37148
Toshinori Mochizuki Incorporator PO Box799, Portland, TN 37148
Rose Hawkins Incorporator 201 Kirgby Dr, Portland, TN 37148

President

Name Role Address
Balaji Dheenadayalan President 1001 Fountain Drive, Forest, MS 39074

Secretary

Name Role Address
Senthil Kumar Natarajan Secretary 1001 Fountain Drive, Forest, MS 39074

Treasurer

Name Role Address
Takayoshi Inaba Treasurer 575 N Sage Rd, White House, TN 37188

Director

Name Role Address
Junichi Takahashi Director 575 N Sage Rd, White House, TN 37188

Filings

Type Status Filed Date Description
Annual Report Filed 2024-04-07 Annual Report For UNIPRES SOUTHEAST U.S.A., INC.
Annual Report Filed 2023-03-17 Annual Report For UNIPRES SOUTHEAST U.S.A., INC.
Annual Report Filed 2022-04-05 Annual Report For UNIPRES SOUTHEAST U.S.A., INC.
Annual Report Filed 2021-04-08 Annual Report For UNIPRES SOUTHEAST U.S.A., INC.
Annual Report Filed 2020-04-01 Annual Report For UNIPRES SOUTHEAST U.S.A., INC.
Amendment Form Filed 2020-02-26 Amendment For UNIPRES SOUTHEAST U.S.A., INC.
Annual Report Filed 2019-04-04 Annual Report For UNIPRES SOUTHEAST U.S.A., INC.
Annual Report Filed 2018-02-15 Annual Report For UNIPRES SOUTHEAST U.S.A., INC.
Annual Report Filed 2017-01-12 Annual Report For UNIPRES SOUTHEAST U.S.A., INC.
Annual Report Filed 2016-03-31 Annual Report For UNIPRES SOUTHEAST U.S.A., INC.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346198526 0419400 2022-09-02 1001 FOUNTAIN DRIVE, FOREST, MS, 39074
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2022-09-28
Emphasis L: AUTOSUP
Case Closed 2023-03-28

Related Activity

Type Accident
Activity Nr 1942109

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100022 A01
Issuance Date 2023-03-01
Abatement Due Date 2023-03-23
Current Penalty 13394.0
Initial Penalty 13394.0
Final Order 2023-03-27
Nr Instances 3
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1):29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. a. Kaizen PM Maintenance - On or about September 27, 2022, an air hose, welding cables and other material were on the floor, exposing employees to a trip hazard. b. Battery Charging and Storage Area - On or about September 27, 2022, oil was on the floor, exposing employees to a slip hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100023 D04
Issuance Date 2023-03-01
Abatement Due Date 2023-03-23
Current Penalty 11162.0
Initial Penalty 11162.0
Final Order 2023-03-27
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(d)(4): The employer did not ensure that the side rails of through or sidestep ladders extend at least 42 inches (1.1 m) above the top of the access level or landing platform served by the ladder. a. Blanking Press Pit - On or about September 27, 2022, the fixed ladder on the north side of the pit, at the end of the press table, did not have side rails that extended at least 42 inches above the landing, exposing employees to a 15 to 20 foot fall hazard onto concrete.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2023-03-01
Abatement Due Date 2023-03-23
Current Penalty 11162.0
Initial Penalty 11162.0
Final Order 2023-03-27
Nr Instances 1
Nr Exposed 20
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. a. Plant - On or about September 28, 2022, periodic inspection of the lockout/tagout procedures were not conducted at least annually, exposing employees to caught in and struck by hazards in the robotic cells from pneumatic, hydraulic and electrical energy sources.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100147 D02
Issuance Date 2023-03-01
Abatement Due Date 2023-03-23
Current Penalty 15625.0
Initial Penalty 15625.0
Final Order 2023-03-27
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a. Assembly Cell 21A - On or about September 2, 2022, the employer did not ensure the robotic spot welding cell was able to be adequately locked out to prevent a struck by hazard to employees.
Citation ID 01005
Citaton Type Serious
Standard Cited 19101030 F02 I
Issuance Date 2023-03-01
Abatement Due Date 2023-03-23
Current Penalty 6696.0
Initial Penalty 6696.0
Final Order 2023-03-27
Nr Instances 1
Nr Exposed 15
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1030(f)(2)(i): Hepatitis B vaccination was not made available within 10 working days of initial assignment to all employee(s) with occupational exposure:Note: Does not apply to employees who have previously received the complete hepatitis B vaccination series, for whom antibody testing has indicated immunity, or for whom the vaccine is contraindicated for medical reasons. a. Plant - On or about September 27, 2022, the designated first aid responders had not been offered the hepatitis B vaccine.
Citation ID 02001
Citaton Type Other
Standard Cited 19100145 E02
Issuance Date 2023-03-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-03-27
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.145(e)(2):The wording of signs was not easily read and concise. a. Die Maintenance - On or about September 27, 2022, the hydraulic die spotter warning signs and labels were written in a foreign language and not understood by the employees.
Citation ID 02002
Citaton Type Other
Standard Cited 19100305 G01 IV A
Issuance Date 2023-03-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-03-27
Nr Instances 2
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. a. Scrap Scales - On or about September 27, 2022, the scrap scales were plugged into relocatable power taps that were daisy changed and plugged into an extension cord.
Citation ID 02003
Citaton Type Other
Standard Cited 19100305 J01 I
Issuance Date 2023-03-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-03-27
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(j)(1)(i):Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact. a. Kaizen PM Maintenance, Behind Zhizouka Drill Press - On or about September 27, 2022, the screws were missing from a receptacle cover and the cover was partially opened.
339798688 0419400 2014-06-05 1001 FOUNTAIN DRIVE, FOREST, MS, 39074
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-06-06
Emphasis L: AUTOSUP, L: FORKLIFT, P: AUTOSUP
Case Closed 2014-07-22

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100253 B04 III
Issuance Date 2014-06-11
Current Penalty 1377.0
Initial Penalty 2295.0
Final Order 2014-07-07
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: (a) Back Dock near Dock Door No. 7 - On or about June 5, 2014 oxygen and acetylene cylinders were improperly stored 18 inches apart.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100254 D09 III
Issuance Date 2014-06-11
Current Penalty 1721.4
Initial Penalty 2869.0
Final Order 2014-07-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replace: (a) Die Maintenance Shop and Kaizen Area - On or about June 5, 2014 the cables on the arc welders were damaged.
Citation ID 02001
Citaton Type Other
Standard Cited 19100147 C04 II
Issuance Date 2014-06-11
Abatement Due Date 2014-07-08
Current Penalty 540.0
Initial Penalty 900.0
Final Order 2014-07-07
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this sec: (a) Jobsite - On or about June 6, 2014, the employer did not have equipment specific energy control procedures for the Nut and Bolt welders in the assembly area.

Court Cases

Docket Number Nature of Suit Filing Date Disposition
1800383 Civil Rights Employment 2018-06-12 settled
Circuit Fifth Circuit
Origin original proceeding
Jurisdiction federal question
Jury Demand Plaintiff demands jury
Demanded Amount 0
Termination Class Action Missing
Procedural Progress other
Nature Of Judgment no monetary award
Judgement missing
Arbitration On Termination Missing
Office 3
Filing Date 2018-06-12
Termination Date 2019-05-10
Date Issue Joined 2018-11-16
Section 1981
Sub Section JB
Status Terminated

Parties

Name JERRELS
Role Plaintiff
Name UNIPRES SOUTHEAST U.S.A., INC.
Role Defendant

Date of last update: 19 Mar 2025

Sources: Mississippi Secretary of State