Search icon

NSB Boats, LLC

Company Details

Name: NSB Boats, LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Good Standing
Effective Date: 30 Oct 2002 (22 years ago)
Business ID: 724626
ZIP code: 38821
County: Monroe
State of Incorporation: MISSISSIPPI
Principal Office Address: 500 WaterWay DriveAmory, MS 38821
Historical names: NAUTIC STAR, LLC

Agent

Name Role Address
CORPORATION SERVICE COMPANY Agent 109 Executive Drive, Suite 3, Madison, MS 39110

Member

Name Role Address
MasterCraft Boat Holdings, Inc. Member 100 Cherokee Cove Drive, Vonore, TN 37885

Filings

Type Status Filed Date Description
Annual Report LLC Filed 2025-03-06 Annual Report For NSB Boats, LLC
Annual Report LLC Filed 2024-03-14 Annual Report For NSB Boats, LLC
Annual Report LLC Filed 2023-04-05 Annual Report For NSB Boats, LLC
Amendment Form Filed 2022-11-14 Amendment For NAUTIC STAR, LLC
Annual Report LLC Filed 2022-04-13 Annual Report For NAUTIC STAR, LLC
Registered Agent Change of Address Filed 2022-03-31 Agent Address Change For CORPORATION SERVICE COMPANY
Annual Report LLC Filed 2021-04-15 Annual Report For NAUTIC STAR, LLC
Annual Report LLC Filed 2020-04-10 Annual Report For NAUTIC STAR, LLC
Annual Report LLC Filed 2019-04-12 Annual Report For NAUTIC STAR, LLC
Annual Report LLC Filed 2018-04-09 Annual Report For NAUTIC STAR, LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341724755 0419400 2016-08-23 500 WATERWAY DRIVE, AMORY, MS, 38821
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2016-08-23
Case Closed 2017-02-21

Related Activity

Type Inspection
Activity Nr 1123182
Health Yes
341680023 0419400 2016-07-22 500 WATERWAY DRIVE, AMORY, MS, 38821
Inspection Type Monitoring
Scope Complete
Safety/Health Safety
Close Conference 2016-07-22
Case Closed 2016-09-08

Related Activity

Type Inspection
Activity Nr 1118458
Safety Yes
341231827 0419400 2016-02-05 500 WATERWAY DRIVE, AMORY, MS, 38821
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2016-02-19
Emphasis L: HINOISE
Case Closed 2016-06-29

Related Activity

Type Referral
Activity Nr 1058603
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100095 G06
Issuance Date 2016-06-01
Abatement Due Date 2016-08-29
Current Penalty 1560.0
Initial Penalty 2295.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels : (a) Griinder - On or about February 22, 2016 grinder operator was exposed to continuous noise at continuous noise of approximately 96 decibels during 400 minutes sampling period. Exposure calculations included a zero increment for the time not sampled.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100134 G01 I A
Issuance Date 2016-06-01
Abatement Due Date 2016-07-01
Current Penalty 1560.0
Initial Penalty 2295.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function. (a) Lamination Small Parts and RTM - On or about January 28, 2016 two painters that were required to wear tight fitting respirators had full beards.
Citation ID 02001
Citaton Type Other
Standard Cited 19100107 B05 I
Issuance Date 2016-06-01
Abatement Due Date 2016-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(5)(i): There were no visible gauge(s), audible alarm(s) or pressure activated device(s) installed on paint spray booth(s) to indicate or insure that the required air velocity was maintained. (a) Paint Booths - On or about February 22, 2016 a gauge was not installed on paint booths to indicate a loss of pressure for changing filters.
Citation ID 02002
Citaton Type Other
Standard Cited 19100141 D02 II
Issuance Date 2016-06-01
Abatement Due Date 2016-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: (a) Restrooms - On or about February 22, 2016 hot water was not provided for employees to wash their hands after using spray guns with styrene.
341184588 0419400 2016-01-15 500 WATERWAY DRIVE, AMORY, MS, 38821
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-01-29
Emphasis L: MARITIME, P: MARITIME
Case Closed 2016-09-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100106 E02 IV A
Issuance Date 2016-06-01
Abatement Due Date 2016-07-01
Current Penalty 4380.0
Initial Penalty 6300.0
Final Order 2016-06-23
Nr Instances 6
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(e)(2)(iv)(a): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were not kept in covered containers when not actually in use: (a) Lamination Staging Area - On or about January 27, 2016 55 gallon drums containing flammable gel coat residue were not covered.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100106 E03 V A
Issuance Date 2016-06-01
Abatement Due Date 2016-08-29
Current Penalty 4380.0
Initial Penalty 6300.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(e)(3)(v)(a): Areas as defined in paragraph (e)(3)(i) of this section using Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were not ventilated at a rate of not less than 1 cubic foot per minute per square foot of solid floor area. This was not accomplished by natural or mechanical ventilation with discharge or exhaust to a safe location outside of the building. Provision was not made for introduction of makeup air in such a manner as not to short circuit the ventilation. Ventilation was not arranged to include all floor areas or pits where flammable vapors may collect. (a) Lamination Mixing Room - On or about January 27, 2016 the mixing room did not have mechanical ventilation or adequate natural ventilation.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100107 B03
Issuance Date 2016-06-01
Abatement Due Date 2016-07-01
Current Penalty 4380.0
Initial Penalty 6300.0
Final Order 2016-06-23
Nr Instances 5
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(3): The floor surface of a spray booth and operator's working area, if combustible, was not covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues. (a) R & D Paint Booth - On or about January 27, 2016 the paint booth floors were covered with combustible paper. The paint booth walls were covered with plastic shrink wrap. The shrink wrap did not provide static dissipation and the shrink wrap did not have a maximum breakdown voltage of 4 kV to prevent accumulation of a hazardous static discharge. (b) Lamination Molding Paint Area - On or about January 27, 2016 the paint booth floors were covered with combustible paper. The paint booth walls were covered with plastic shrink wrap. The shrink wrap did not provide static dissipation. The shrink wrap did not have a maximum breakdown voltage of 4 kV to prevent accumulation of a hazardous static discharge
Citation ID 01004
Citaton Type Serious
Standard Cited 19100107 B05 IV
Issuance Date 2016-06-01
Abatement Due Date 2016-08-09
Current Penalty 2600.0
Initial Penalty 3825.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: (a) R & D Paint Booth - On or about January 27, 2016 the paint booth did not have a sprinkler system.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100107 C06
Issuance Date 2016-06-01
Abatement Due Date 2016-08-29
Current Penalty 4380.0
Initial Penalty 6300.0
Final Order 2016-06-23
Nr Instances 2
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: (a) Facility - On or about January 27, 2016 the lighting, electrical panels, receptacles and equipment in the following locations were not rated for Class 1, Division 1 areas. (i) R & D Spray Area - On or about January 27, 2016 electrical receptacles, electrical panels on the outside of the paint booth, bench grinder and battery chargers on work table within 20 feet of the spray area were not explosion proof. (ii) Lamination Small Parts - On or about January 27, 2016 electrical panels, electrical disconnects and exhaust fan on the wall between the ventilation systems were within 20 feet of the spray area and were not explosion proof. (ii) Lamination Molding Paint Booths - On or about January 27, 2016 fluorescent light fixtures and wiring were not explosion proof. Gel coat residue was on the light fixtures and on the wall at or above the light fixtures. (iv) Mixing Room - On or about January 27, 2016 fluorescent light fixture, orange extension cord and radio was not explosion proof.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100107 C09 I
Issuance Date 2016-06-01
Abatement Due Date 2016-08-09
Current Penalty 4380.0
Initial Penalty 6300.0
Final Order 2016-06-23
Nr Instances 6
Nr Exposed 20
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(c)(9)(i): All metal parts of spray booths, exhaust ducts, and piping systems conveying flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) or aerated solids were not properly electrically grounded in an effective and permanent manner: (a) R & D - On or about January 27, 2016 Magnum Venus Paint (MVP) sprayers and chopper sprayers were not grounded. (b) Lamination - On or about January 27, 2016 the Magnum Venus Paint (MVP) sprayers and chopper sprayers were not grounded. (c) Offshore - On or about January 27, 2016 the Magnum Venus Paint (MVP) sprayers and chopper sprayers were not grounded.
Citation ID 01007
Citaton Type Serious
Standard Cited 19100107 G02
Issuance Date 2016-06-01
Abatement Due Date 2016-07-01
Current Penalty 4380.0
Initial Penalty 6300.0
Final Order 2016-06-23
Nr Instances 4
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(g)(2): All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of non-sparking material. (a) Lamination Molding Painting Area - On or about January 27, 2016 painting area number 4 had an excessive amount of gel coat build-up in the back of the room.
Citation ID 01008
Citaton Type Serious
Standard Cited 19100147 C07 I
Issuance Date 2016-06-01
Abatement Due Date 2016-07-29
Current Penalty 2080.0
Initial Penalty 3060.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) Throughout Facility - On or about January 28, 2016 the employer failed to train all affected and authorized maintenance employees on the energy control program to ensure they understand the hazards and have the skills required for the safe application and removal of energy controls.
Citation ID 01009
Citaton Type Serious
Standard Cited 19100304 G05
Issuance Date 2016-06-01
Abatement Due Date 2016-07-01
Current Penalty 1660.0
Initial Penalty 2295.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 10
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. (a) Offshore - On or about January 15, 2016 an extension cord used for a handheld DeWalt buffer did not have a grounding prong.
Citation ID 01010
Citaton Type Serious
Standard Cited 19100305 A02 IX
Issuance Date 2016-06-01
Abatement Due Date 2016-07-29
Current Penalty 2090.0
Initial Penalty 3060.0
Final Order 2016-06-23
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded. (a) Store, Parts Room - On or about January 27, 2016 light fixtures above storage racks were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard.
Citation ID 01011
Citaton Type Serious
Standard Cited 19100305 B02 I
Issuance Date 2016-06-01
Abatement Due Date 2016-07-29
Current Penalty 2090.0
Initial Penalty 3060.0
Final Order 2016-06-23
Nr Instances 5
Nr Exposed 220
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) Employee Break Rooms - On or about January 28, 2016 two electrical outlets used to supply power for the two Coca-Cola vending machines were not protected from electrical shock by the use of cover plates.
Citation ID 01012A
Citaton Type Serious
Standard Cited 19100305 G01 IV A
Issuance Date 2016-06-01
Abatement Due Date 2016-08-29
Current Penalty 1660.0
Initial Penalty 2295.0
Final Order 2016-06-23
Nr Instances 7
Nr Exposed 220
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure (a) Throughout Building - On or about January 28, 2016 electrical extension cords were being used instead of permanent wiring to supply power to power strips.
Citation ID 01012B
Citaton Type Serious
Standard Cited 19100305 G01 IV B
Issuance Date 2016-06-01
Abatement Due Date 2016-08-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: (a) Paint Room Adjacent to Forman's Office - On or about January 27, 2016 the overhead electrical door power cord is fed through a hole in the metal wall.
Citation ID 01013
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2016-06-01
Abatement Due Date 2016-08-29
Current Penalty 3220.0
Initial Penalty 4590.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 200
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Throughout Facility - On or about January 28, 2016 employees exposed to hazardous chemicals such as, but not limited to, vinylester gel coat, resin and organic peroxide had not received hazard communication training.
Citation ID 02001
Citaton Type Other
Standard Cited 19100159 C10
Issuance Date 2016-06-01
Abatement Due Date 2016-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.159(c)(10): The minimum vertical clearance of 18 inches between automatic sprinkler systems sprinklers and the material below was not maintained: (a) Material Storage Room - On or about January 29, 2016 material stored on top storage rack was within the 18 inches minimum vertical clearance of the automatic sprinkler head.
Citation ID 02002
Citaton Type Other
Standard Cited 19100178 A04
Issuance Date 2016-06-01
Abatement Due Date 2016-08-29
Current Penalty 100.0
Initial Penalty 765.0
Final Order 2016-06-23
Nr Instances 5
Nr Exposed 15
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: (a) Throughout Building - On or about January 28, 2016 employees operating electrical hand trucks that have been modified without the manufacturer's prior written approval.
Citation ID 02003
Citaton Type Other
Standard Cited 19100303 G01
Issuance Date 2016-06-01
Abatement Due Date 2016-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Lamination, Small Parts Spray Area - On or about January 28, 2016 employees did not have ready access to the electrical panels in case of an emergency. The electrical panels were covered with plastic shrink wrap and two 55 gallon drums were against the panels.
Citation ID 02004
Citaton Type Other
Standard Cited 19100304 B03 II C 3
Issuance Date 2016-06-01
Abatement Due Date 2016-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug were not visually inspected before use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage, and equipment found damaged or defective was not removed from use until repaired: (a) Offshore - On or about January 15, 2016 extension cords for the hand held buffers had torn outer insulation throughout the length of the cords.
Citation ID 02005
Citaton Type Other
Standard Cited 19100305 G02 III
Issuance Date 2016-06-01
Abatement Due Date 2016-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. (a) Lamination RTM - On or about January 27, 2016 Toyota electric hand power cord plug did not have strain relief.
Citation ID 02006
Citaton Type Other
Standard Cited 19101200 F06
Issuance Date 2016-06-01
Abatement Due Date 2016-07-01
Current Penalty 100.0
Initial Penalty 765.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier, signal word, hazard statement(s), pictogram(s), precautionary statement(s) and name, address, and telephone number of the chemical manufacturer, importer, or other responsible party. (a) Lamination RTM Resin Transfer Mold - On or about January 27, 2016 a 5 gallon bucket containing scrap gel coat was not labeled.

Date of last update: 20 Mar 2025