Search icon

Jackson Precast, Inc.

Headquarter

Company Details

Name: Jackson Precast, Inc.
Jurisdiction: MISSISSIPPI
Business Type: Profit Corporation
Status: Good Standing
Effective Date: 30 Mar 2004 (21 years ago)
Business ID: 853462
ZIP code: 39213
County: Hinds
State of Incorporation: MISSISSIPPI
Principal Office Address: 3325 Lawson StreetJackson, MS 39213

Links between entities

Type Company Name Company Number State
Headquarter of Jackson Precast, Inc., ALABAMA 000-008-822 ALABAMA

Agent

Name Role Address
De Voss, Matthew Agent 3325 Lawson Street, Jackson, MS 39213

Incorporator

Name Role Address
Penick Iv, William C. Incorporator 248 East Capitol Street, Suite 1400, Jackson, MS 39201

Director

Name Role Address
Jay Matthew Devoss Director 3325 Lawson Street, Jackson, MS 39213
James E Tolson Jr Director 5608 Shady Elm Circle, Plano, TX 75093

President

Name Role Address
Jay Matthew Devoss President 3325 Lawson Street, Jackson, MS 39213

Secretary

Name Role Address
James E Tolson Jr Secretary 5608 Shady Elm Circle, Plano, TX 75093

Filings

Type Status Filed Date Description
Annual Report Filed 2025-01-17 Annual Report For Jackson Precast, Inc.
Annual Report Filed 2024-01-15 Annual Report For Jackson Precast, Inc.
Annual Report Filed 2023-01-16 Annual Report For Jackson Precast, Inc.
Annual Report Filed 2022-04-04 Annual Report For Jackson Precast, Inc.
Annual Report Filed 2021-02-05 Annual Report For Jackson Precast, Inc.
Annual Report Filed 2020-02-03 Annual Report For Jackson Precast, Inc.
Annual Report Filed 2019-03-05 Annual Report For Jackson Precast, Inc.
Annual Report Filed 2018-01-30 Annual Report For Jackson Precast, Inc.
Annual Report Filed 2017-01-19 Annual Report For Jackson Precast, Inc.
Annual Report Filed 2016-02-09 Annual Report For Jackson Precast, Inc.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337613814 0419400 2012-11-27 3325 LAWSON STREET, JACKSON, MS, 39213
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2012-11-28
Emphasis L: FALL, L: FORKLIFT, L: HINOISE, P: HINOISE
Case Closed 2014-04-30

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100023 A08
Issuance Date 2013-03-19
Abatement Due Date 2013-03-26
Current Penalty 945.0
Initial Penalty 1890.0
Final Order 2013-04-09
Nr Instances 2
Nr Exposed 36
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk shall be guarded by either: (a) Bathroom - On or about November 7, 2012 two floor holes four inches wide and two inches in depth were not guarded by a cover.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100095 C01
Issuance Date 2013-03-19
Abatement Due Date 2013-04-12
Current Penalty 1339.0
Initial Penalty 2678.0
Final Order 2013-04-09
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(c)(1): The employer shall administer a continuing, effective hearing conservation program, as described in paragraphs (c) through (o) of this section, whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level (TWA) of 85 decibels measured on the A scale (slow response) or, equivalently, a dose of fifty percent. For purposes of the hearing conservation program, employee noise exposures shall be computed in accordance with appendix A and Table G-16a, and without regard to any attenuation provided by the use of personal protective equipment. (a) On or about December 7, 2012 the employer had not implemented a hearing conservation program for a sandblaster that was exposed to noise levels of 98.1 for a 8-hour time weighted average while performing sandblasting activities.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100095 G01
Issuance Date 2013-03-19
Abatement Due Date 2013-04-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-04-09
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(g)(1): The employer shall establish and maintain an audiometric testing program as provided in this paragraph by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels. (a) On or about December 7, 2012 the employer had not establish and maintained audiometeric testing for exployees exposed to noise levels that exceeded an 8 hour time-weighted average od 85 decibels.
Citation ID 01003
Citaton Type Other
Standard Cited 19100141 D02 II
Issuance Date 2013-03-19
Abatement Due Date 2013-04-12
Current Penalty 945.0
Initial Penalty 1890.0
Final Order 2013-04-09
Nr Instances 2
Nr Exposed 36
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(d)(2)(ii): Each lavatory shall be provided with hot and cold running water, or tepid running water. (a) On or about Novemeber 7, 2012 employee restroom was not equipped with hot or tepid running water.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100213 I01
Issuance Date 2013-03-19
Abatement Due Date 2013-03-29
Current Penalty 1260.0
Initial Penalty 2520.0
Final Order 2013-04-09
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(i)(1): All portions of the saw blade shall be enclosed or guarded, except for the working portion of the blade between the bottom of the guide rolls and the table. Bandsaw wheels shall be fully encased. The outside periphery of the enclosure shall be solid. The front and back of the band wheels shall be either enclosed by solid material or by wire mesh or perforated metal. Such mesh or perforated metal shall be not less than 0.037 inch (U.S. Gage No. 20), and the openings shall be not greater than three-eighths inch. Solid material used for this purpose shall be of an equivalent strength and firmness. The guard for the portion of the blade between the sliding guide and the upper-saw-wheel guard shall protect the saw blade at the front and outer side. This portion of the guard shall be self-adjusting to raise and lower with the guide. The upper-wheel guard shall be made to conform to the travel of the saw on the wheel. (a) On or about November 7, the Rockwell 14 inch band saw in the carpenter shop blade was not guarded at the point of operation.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100303 F01
Issuance Date 2013-03-19
Abatement Due Date 2013-03-29
Current Penalty 1071.0
Initial Penalty 2142.0
Final Order 2013-04-09
Nr Instances 3
Nr Exposed 36
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(f)(1): Motors and appliances. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. (a) On or about December 7, 2012 electrical panel box in the Production Bay #1 was not label as to what it control for quick disconnect purposes. (b) On or about December 7, 2012 electrical panel box in the Break Room was not label as to what it control for quick disconnect purposes. c.) On or about December 7, 2012 electrical panel box in the Welding Shop was not label as to what it control for quick disconnect purposes.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100305 B01 II
Issuance Date 2013-03-19
Abatement Due Date 2013-03-25
Current Penalty 2205.0
Initial Penalty 4410.0
Final Order 2013-04-09
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. (a) On or about November 26, 2012 in the Rebar Department employees were exposed to elecectrical shock hazards because of open spaces in a 220 volt panel box.
Citation ID 01007
Citaton Type Other
Standard Cited 19100305 G02 III
Issuance Date 2013-03-19
Abatement Due Date 2013-03-26
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2013-04-09
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. (a) on or about November 7, 2012 the Rebar Cutter and Bender machine strain release was broken exposing live wiring exposing employees to electrical shock.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
2256608508 2021-02-20 0470 PPS 3325 Lawson St, Jackson, MS, 39213-5741
Loan Status Date 2021-12-22
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 306500
Loan Approval Amount (current) 306500
Undisbursed Amount 0
Franchise Name -
Lender Location ID 71783
Servicing Lender Name Frost Bank
Servicing Lender Address 111 W Houston St, SAN ANTONIO, TX, 78205-1414
Rural or Urban Indicator U
Hubzone Y
LMI N
Business Age Description Existing or more than 2 years old
Project Address Jackson, HINDS, MS, 39213-5741
Project Congressional District MS-02
Number of Employees 32
NAICS code 327331
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 71783
Originating Lender Name Frost Bank
Originating Lender Address SAN ANTONIO, TX
Gender Male Owned
Veteran Unanswered
Forgiveness Amount 308708.48
Forgiveness Paid Date 2021-11-15
7140847003 2020-04-07 0470 PPP 3325 LAWSON ST, JACKSON, MS, 39213-5741
Loan Status Date 2021-05-21
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 251700
Loan Approval Amount (current) 251700
Undisbursed Amount 0
Franchise Name -
Lender Location ID 71783
Servicing Lender Name Frost Bank
Servicing Lender Address 111 W Houston St, SAN ANTONIO, TX, 78205-1414
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Existing or more than 2 years old
Project Address JACKSON, HINDS, MS, 39213-5741
Project Congressional District MS-02
Number of Employees 38
NAICS code 327331
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 71783
Originating Lender Name Frost Bank
Originating Lender Address SAN ANTONIO, TX
Gender Male Owned
Veteran Unanswered
Forgiveness Amount 254292.85
Forgiveness Paid Date 2021-04-28

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
1275388 Intrastate Non-Hazmat 2004-07-02 - - 1 1 Private(Property)
Legal Name JACKSON PRECAST INC
DBA Name -
Physical Address 3325 LAWSON STREET, JACKSON, MS, 39213, US
Mailing Address 3325 LAWSON STREET, JACKSON, MS, 39213, US
Phone (601) 321-8787
Fax (601) 321-8992
E-mail KCAMPBELL@JPI.MS

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 26 Mar 2025