345420582
|
0419400
|
2021-07-13
|
311 TUSCALOOSA ROAD, COLUMBUS, MS, 39705
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2021-07-13
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2021-07-28
|
|
343773420
|
0419400
|
2019-02-08
|
509 UNIVERSITY DRIVE, STARKVILLE, MS, 39759
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-02-08
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2019-03-11
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 II |
Issuance Date |
2019-03-05 |
Current Penalty |
2386.8 |
Initial Penalty |
3978.0 |
Final Order |
2019-03-11 |
Nr Instances |
5 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(ii): Covers were not provided for holes in which an employee on a walking/working surface could trip or step: (a) Breezeway Between Phase 1 and Phase 2 - On or about February 08, 2019 17 inch deep open floor holes for the mounting of structural steel uprights were not covered. Employees were exposed to trip and fall hazards. |
|
|
341346369
|
0419400
|
2016-03-22
|
111 CONFEDERATE DR., CALEDONIA, MS, 39740
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-03-22
|
Emphasis |
L: FALL, L: FORKLIFT, N: CTARGET, P: CTARGET
|
Case Closed |
2016-03-25
|
|
341095933
|
0419400
|
2015-12-03
|
505 2ND AVENUE NORTH, COLUMBUS, MS, 39701
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-12-03
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2015-12-22
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260405 A02 II I |
Issuance Date |
2015-12-15 |
Current Penalty |
1428.0 |
Initial Penalty |
2380.0 |
Final Order |
2015-12-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables were not protected from damage, sharp corners and projections, or pinch points. (a) Job Trailer - On or about December 03, 2015 two extensions cords were not protected from the sharp corner of a opening and closing door. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 II |
Issuance Date |
2015-12-15 |
Current Penalty |
1428.0 |
Initial Penalty |
2380.0 |
Final Order |
2015-12-22 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76cm) whichever is less were not equipped with one stairrail system along each unprotected side or edge: (a) Jobsite - On or about December 03, 2015 open sided wooden stairways did not have complete stairrail systems. - Storage Trailer - Office Trailer |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2015-12-15 |
Current Penalty |
1428.0 |
Initial Penalty |
2380.0 |
Final Order |
2015-12-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed. (a) Jobsite - On or about December 03, 2015 an 8 foot fiberglass folding ladder was used as as a straight ladder. |
|
|
339609380
|
0419400
|
2014-02-25
|
2031 US HWY 45 NORTH, COLUMBUS, MS, 39705
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-02-25
|
Emphasis |
L: FALL, L: FORKLIFT, N: TRENCH, P: FALL
|
Case Closed |
2014-04-17
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2014-04-07 |
Abatement Due Date |
2014-04-11 |
Current Penalty |
1285.2 |
Initial Penalty |
2142.0 |
Final Order |
2014-04-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as follows: (a) Scaffold - On or about February 25, 2014 an employee was exposed to a fall hazard from a scaffold not being fully decked or planked. Only one deck was installed on the scaffold. Employee would fall 13.8 feet to broken concrete. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2014-04-07 |
Abatement Due Date |
2014-04-11 |
Current Penalty |
1606.8 |
Initial Penalty |
2678.0 |
Final Order |
2014-04-17 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. (a) Scaffold - On or about February 25, 2014 an employee was exposed to a fall hazard while standing on a scaffold 13.8 feet above concrete with no base-plates installed. (b) Scaffold - On or about February 25, 2014 three employees were exposed to a fall hazard while standing on a scaffold 9 feet above concrete with no base-plates installed. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2014-04-07 |
Abatement Due Date |
2014-04-11 |
Current Penalty |
1606.8 |
Initial Penalty |
2678.0 |
Final Order |
2014-04-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. (a) Scaffold - On or about February 25, 2014 an employee was exposed to a fall hazard while standing on a scaffold 13.8 feet above concrete. Employees were not protected from falling to a lower level by a guardrail system or personal fall arrest system or safety net system. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260452 W01 |
Issuance Date |
2014-04-07 |
Abatement Due Date |
2014-04-11 |
Current Penalty |
1285.2 |
Initial Penalty |
2142.0 |
Final Order |
2014-04-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(w)(1): Scaffolds was not braced by cross, horizontal, or diagonal braces, or combination thereof, to prevent racking or collapse of the scaffold and to secure vertical members together laterally so as to automatically square and align the vertical members. Scaffolds shall be plumb, level, and squared. All brace connections were not secured. (a) Scaffold - On or about February 25, 2014 employees were exposed to a fall hazard of 13.8 feet while working on a scaffold that was missing cross-braces on the front and back-side. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2014-04-07 |
Abatement Due Date |
2014-05-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-04-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employers did not maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: (a) Construction Site - On or about February 25, 2014 the employer did not maintain a written hazard communication program. Employees were handling Crown paint thinner. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260451 F07 |
Issuance Date |
2014-04-07 |
Abatement Due Date |
2014-04-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-04-17 |
Nr Instances |
4 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person. (a) Scaffold - On or about February 25, 2014 employees were exposed to a fall hazard from scaffold not being erected and altered under the supervision of a competent person. |
|
|