345921852
|
0419400
|
2022-04-26
|
4665 WINSTEAD ROAD, MERIDIAN, MS, 39307
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2022-04-26
|
Case Closed |
2022-04-27
|
Related Activity
Type |
Inspection |
Activity Nr |
1556900 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1557037 |
Health |
Yes |
|
|
345569008
|
0419400
|
2021-10-04
|
4665 WINSTEAD ROAD, MERIDIAN, MS, 39307
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2021-10-04
|
Emphasis |
N: AMPUTATE, N: DUSTEXPL
|
Case Closed |
2023-04-03
|
Related Activity
Type |
Complaint |
Activity Nr |
1814204 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1557037 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
2237.4 |
Initial Penalty |
3729.0 |
Final Order |
2022-03-08 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: A struck-by hazard from PVC piping used to transport compressed air from an air compressor to the shop areas. a. Shop Area - On or about October 4, 2021 employees were exposed to struck-by hazards while working with and around Polyvinyl Chloride (PVC) pipes that were used to transport compressed air at 90 psi in the front shop area and 130 psi in the spray room. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100305 J01 I |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
1119.0 |
Initial Penalty |
1865.0 |
Final Order |
2022-03-08 |
Nr Instances |
3 |
Nr Exposed |
7 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(j)(1)(i):Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact: a. Shop - On or about October 4, 2021 electrical receptacles located in the front shop area and paint booth area did not have faceplates to prevent contact with energized parts. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 A01 |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-03-08 |
Nr Instances |
1 |
Nr Exposed |
7 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. a. Shop Area - On or about October 4, 2021 wood dust was on the walls, ceiling and equipment exposing employees to a fire hazard. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100303 B02 |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-03-08 |
Nr Instances |
1 |
Nr Exposed |
7 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. a. Paint Booth Area - On or about October 4, 2021 an electrical receptacle located in the paint booth area had an opened neutral exposing employees to a fire hazard. |
|
|
345570378
|
0419400
|
2021-10-04
|
4665 WINSTEAD ROAD, MERIDIAN, MS, 39307
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2021-10-04
|
Emphasis |
N: AMPUTATE, N: DUSTEXPL
|
Case Closed |
2023-06-27
|
Related Activity
Type |
Inspection |
Activity Nr |
1556900 |
Safety |
Yes |
|
Type |
Complaint |
Activity Nr |
1814204 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
1119.0 |
Initial Penalty |
1865.0 |
Final Order |
2023-03-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Variance |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1):A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Facility - On or about October 4, 2021 the employer did not have a written respiratory protection program for employees required to wear a 3M Half Facepiece respirator during painting, exposing employees to respiratory hazards. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-03-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace: Facility - On or about October 4, 2021 the employer did not provide a medical evaluation for the painter using a 3M half face piece respirator exposing the employees to respiratory hazards. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100134 F02 |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-03-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece was used, and at least annually thereafter: Facility - On or about October 4, 2021 the employer did not ensure that the painter was fit tested prior to using a 3M half face piece respirator exposing employees to respiratory hazards. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100134 K |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-03-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k): The employer did not provided effective training to employees who are required to use respirators: Facility - On or about October 4, 2021 2021 the employer did not provide respiratory training to the employee(s) required to use a 3m half face piece respirator exposing employees to respiratory hazards. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100106 E02 IV D |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
1119.0 |
Initial Penalty |
1865.0 |
Final Order |
2023-03-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve. (A) Paint storage area - On or about October 4, 2021, employees were exposed to fire hazards in that a 55-gallon container of flammable solvent (Ultra-Kleen Spray Equipment Solution - 5113) did not have a self closing valve. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100106 E06 II |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-03-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: (A) Paint storage area - On or about October 4, 2021, employees were exposed to fire hazards due to static electricity discharge ignition of flammable solvent (Ultra-Kleen Spray Equipment Solution - 5113) while being dispensed into secondary containers without being bonded. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
1119.0 |
Initial Penalty |
1865.0 |
Final Order |
2023-03-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1):The employer did not develop, implement and maintain at the workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g) and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met: (a) Facility - On or about October 4, 2021 employees were exposed to chemical exposure hazards due to the employer had not developed a written hazard communication program governing the use of chemicals such as but not limited to paint reducers, hardeners, stains and other hazardous chemicals. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2022-01-26 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-03-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work areas at the time of their initial assignment and whenever a new hazard that the employees had not been trained about was introduced into their work area: (a) Facility - On or about October 4, 2021 employees were exposed to chemical exposure due to the lack of training on the chemicals being utilized in the workplace such as but not limited to paint reducers, hardeners, stains and other hazardous chemicals. |
|
|