Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-12-31
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2016-03-24
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2016-03-01 |
Abatement Due Date |
2016-03-03 |
Current Penalty |
6700.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-03-24 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. (a) Porch area - On or about December 31, 2015 employees were exposed to a fall hazard while working on a flat roof 28 feet above concrete with no fall protection. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2016-03-01 |
Abatement Due Date |
2016-03-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-03-24 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): "Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. (a) Main Roof of Priority One Bank - On or about December 31, 2015 employees were exposed to a fall hazard while working on a steep roof 35 feet the ground with no fall protection. The pitch of the roof was 7/12. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260502 H01 III |
Issuance Date |
2016-03-01 |
Abatement Due Date |
2016-03-03 |
Current Penalty |
0.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-03-24 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(h)(1)(iii): The safety monitor shall be on the same walking/working surface and within visual sighting distance of the employee being monitored (a) Porch area - On or about December 31, 2015 employees were exposed to a fall hazard while working on a flat roof due to the safety monitor not being on the same level and not actively observing all employees involved in work on the roof. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2016-03-01 |
Abatement Due Date |
2016-03-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-03-24 |
Nr Instances |
3 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: (a) Priority One Bank (construction site) - On or about December 31, 2015 the employer did not maintain a Hazardous Communication Program. Employees were exposed to potential serious injury while using a Flammable Liquid known as Firestone Ultra-Ply Bonding Adhesive without the availability of a Safety Data Sheet (SDS) in the work area. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19261412 K |
Issuance Date |
2016-03-01 |
Abatement Due Date |
2016-03-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-03-24 |
Nr Instances |
5 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1412(k): All documents produced under this section must be available, during the applicable document retention period, to all persons who conduct inspections under this section. [75 FR 48146, August 9, 2010] (a) Priority One Bank - On or about December 31, 2015 there was a crane truck in operation with no crane current records available on-site for inspection. The records inside the vehicle were from 2011. Crane records such as: load charts, operator manual, operating speeds, special hazard warnings, instructions were not current or available for inspection. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19261413 E |
Issuance Date |
2016-03-01 |
Abatement Due Date |
2016-03-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-03-24 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1413(e): All documents produced under this section must be available, during the applicable document retention period, to all persons who conduct inspections under this section. [75 FR 48148, August 9, 2010] (a) Priority One Bank - On or about December 31, 2015 there was a crane truck in operation with no crane current records available on-site for inspection. The records inside the vehicle were from 2011. Crane record such as: wire rope inspection records were not current or available for inspection. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19261417 C01 |
Issuance Date |
2016-03-01 |
Abatement Due Date |
2016-03-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-03-24 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1417(c)(1): The procedures applicable to the operation of the equipment, including rated capacities (load charts), recommended operating speeds, special hazard warnings, instructions, and operator's manual, must be readily available in the cab at all times for use by the operator. (a) Priority One Bank - On or about December 31, 2015 there was a crane truck in operation with no crane current records available on-site for inspection. The records inside the vehicle were from 2011. Crane records such as: safety device or operational aid, critical part control system, power plant, braking system, load sustaining structure, structural components etc. were not current or available for inspection. |
|
|