344792924
|
0419400
|
2020-06-16
|
6509 WASHINGTON AVE., OCEAN SPRINGS, MS, 39564
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2020-06-16
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-07-18
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 F15 |
Issuance Date |
2020-08-07 |
Abatement Due Date |
2020-09-01 |
Current Penalty |
5398.0 |
Initial Penalty |
5398.0 |
Final Order |
2020-10-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(15): Ladders were used on scaffolds to increase the working level height of employees: without satisfying the criteria of subparagraphs (i) - (iv) of this paragraph.Note: This paragraph does not apply to large area scaffolds where the employer has satisfied the following criteria: the ladder was placed against a structure which was not a part of the scaffold and the scaffold was secured against the sideways. (a) Front of building - On or about June 16, 2020 the employer allowed employees working from the scaffolding to use a step ladder to increase their working level, exposing employees to fall hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260451 E01 |
Issuance Date |
2020-08-07 |
Abatement Due Date |
2020-09-01 |
Current Penalty |
433.0 |
Initial Penalty |
433.0 |
Final Order |
2020-10-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a) East side of scaffolding - On or about June 16, 2020 The employer allowed employees working from the welded tubular scaffolding to access through the cross bracing, exposing them to falls hazards. |
|
|
339087959
|
0419400
|
2013-05-23
|
1785 BEACH BLVD, BILOXI, MS, 39531
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-05-23
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-09-05
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B02 |
Issuance Date |
2013-06-25 |
Abatement Due Date |
2013-07-08 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide: (a) 1785 Beach Blvd in Biloxi, MS - On or about May 23, 2013, an employee was using a 2 by 12 board for a scaffold platform. The actual width was 11.5 inches. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E08 |
Issuance Date |
2013-06-25 |
Abatement Due Date |
2013-07-08 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(8): Direct access to or from another surface was used when the scaffold was more than 14 inches (36 cm) horizontally and/or 24 inches (61 cm) vertically from the other surface: (a) 1785 Beach Blvd in Biloxi, MS - On or about May 23, 2013, an employee was standing with one foot on a scaffold platform and the other foot about 36 inches away to another surface on a wall. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2013-06-25 |
Abatement Due Date |
2013-07-08 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) 1785 Beach Blvd in Biloxi, MS - On or about May 23, 2013, an employee was working between one of the scaffolds and the edge of the 2nd floor without any fall protection. The edge of the 2nd floor was 17 feet above the ground. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2013-06-25 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-07-23 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access. (a) 1785 Beach Blvd in Biloxi, MS - On or about May 23, 2013, the extension ladder used by employees to access the 2nd floor extended only 6 inches above the upper landing. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260451 B01 |
Issuance Date |
2013-06-25 |
Abatement Due Date |
2013-07-08 |
Current Penalty |
5600.0 |
Initial Penalty |
5600.0 |
Final Order |
2013-07-23 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): 29 CFR 1926.450(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: (a) 1785 Beach Blvd in Biloxi, MS - On or about May 23, 2013, employees were using two scaffolds in which the working platforms were not fully planked on either scaffold. HOBBS CONSTRUCTION, LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.451(b)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 311417976 CITATION NUMBER 1, ITEM NUMBER 3, ISSUED ON 01/08/2009, WITH A FINAL ORDER DATE OF 2/3/2009, WITH RESPECT TO A WORKPLACE LOCATED AT 10495 HWY 49 SOUTH IN GULFPORT, MS. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19260451 G01 |
Issuance Date |
2013-06-25 |
Abatement Due Date |
2013-07-08 |
Current Penalty |
4000.0 |
Initial Penalty |
4000.0 |
Final Order |
2013-07-23 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) 1785 Beach Blvd in Biloxi, MS - On or about May 23, 2013, employees was working from two different scaffold platforms on seperate scaffolds that were both 10 feet 3 inches above the floor. HOBBS cONSTRUCTION, LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.451(g)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 311417976 CITATION NUMBER 1, ITEM NUMBER 5, ISSUED ON 01/08/2009, WITH A FINAL ORDER DATE OF 2/3/2009, WITH RESPECT TO A WORKPLACE LOCATED AT 10495 HWY 49 SOUTH IN GULFPORT, MS. |
|
|
311417976
|
0419400
|
2008-12-18
|
10495 HWY 49 SOUTH, GULFPORT, MS, 39503
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-12-18
|
Emphasis |
L: FALL, S: FALL FROM HEIGHT
|
Case Closed |
2009-09-14
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2009-01-08 |
Abatement Due Date |
2009-01-23 |
Current Penalty |
300.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 A01 |
Issuance Date |
2009-01-08 |
Abatement Due Date |
2009-01-23 |
Current Penalty |
300.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2009-01-08 |
Abatement Due Date |
2009-01-23 |
Current Penalty |
300.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 V |
Issuance Date |
2009-01-08 |
Abatement Due Date |
2009-01-23 |
Current Penalty |
300.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2009-01-08 |
Abatement Due Date |
2009-01-23 |
Current Penalty |
300.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
|