Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-10-24
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-03-05
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2014-12-18 |
Abatement Due Date |
2014-12-31 |
Current Penalty |
2400.0 |
Initial Penalty |
2400.0 |
Final Order |
2015-01-14 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Construction Site - On or about October 24, 2014, the grounding prongs were missing from three extension cords. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 III |
Issuance Date |
2014-12-18 |
Abatement Due Date |
2014-12-31 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(iii): Each employee on a crawling board (chicken ladder) was not protected by a personal fall arrest system, a guardrail system (with minimum 200 pound toprail capacity), or by a three-fourth inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board; a) Construction Site - On or about October 24, 2014, an employee was working from a crawling board (chicken ladder) without using any form of fall protection. The employee was exposed to a 16.7 feet fall. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260452 A04 |
Issuance Date |
2014-12-18 |
Abatement Due Date |
2014-12-31 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(a)(4): Diagonal bracing in both directions were not installed across the entire outside face of all double- and single-pole scaffolds. a) Construction Site - On or about October 24, 2014, an employee was working from a crawling board (chicken ladder) and a single pole scaffold without having cross bracing on the scaffold poles. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260454 A |
Issuance Date |
2014-12-18 |
Abatement Due Date |
2014-12-31 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Construction Site - On or about October 24, 2014, the employees had not received scaffold training. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260416 E01 |
Issuance Date |
2014-12-18 |
Abatement Due Date |
2014-12-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used. a) Construction Site - On or about October 24, 2014, A circular skill saw was plugged into an extension cord that had torn outer insulation at the female plug. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260451 C02 |
Issuance Date |
2014-12-18 |
Abatement Due Date |
2014-12-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) Construction Site - On or about October 24, 2014, an employee was working from a crawling board (chicken ladder) and a pole scaffold without having mud sills under each support leg. |
|
|