Search icon

Montel Builders, LLC

Company Details

Name: Montel Builders, LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Dissolved
Effective Date: 09 Mar 2006 (19 years ago)
Business ID: 888197
ZIP code: 39046
County: Madison
State of Incorporation: MISSISSIPPI
Principal Office Address: 323 A HAWKINS THOMPSON LN.CANTON, MS 39046

Agent

Name Role Address
Thompson, Montel C Agent 323 A Hawkins-Thompson Lane, Canton, MS 39046

Member

Name Role Address
Phillip M Nelson Member 1220 Highway 51 North, Madison, MS 39110

Manager

Name Role Address
Montel Thompson Manager 323 A HAWKINS THOMPSON LN., CANTON, MS 39046

Filings

Type Status Filed Date Description
Admin Dissolution Filed 2012-12-07 Admin Dissolution
Notice to Dissolve/Revoke Filed 2012-09-14 Notice to Dissolve/Revoke
Annual Report LLC Filed 2011-05-11 Annual Report LLC
Formation Form Filed 2006-03-09 Formation

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340037738 0419400 2014-10-24 LOT 52, ST. REGIS SUBDIVISION, MADISON, MS, 39110
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-10-24
Emphasis L: FALL, P: FALL
Case Closed 2018-03-05

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2014-12-18
Abatement Due Date 2014-12-31
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2015-01-14
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Construction Site - On or about October 24, 2014, the grounding prongs were missing from three extension cords.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 III
Issuance Date 2014-12-18
Abatement Due Date 2014-12-31
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2015-01-14
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(iii): Each employee on a crawling board (chicken ladder) was not protected by a personal fall arrest system, a guardrail system (with minimum 200 pound toprail capacity), or by a three-fourth inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board; a) Construction Site - On or about October 24, 2014, an employee was working from a crawling board (chicken ladder) without using any form of fall protection. The employee was exposed to a 16.7 feet fall.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260452 A04
Issuance Date 2014-12-18
Abatement Due Date 2014-12-31
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2015-01-14
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(a)(4): Diagonal bracing in both directions were not installed across the entire outside face of all double- and single-pole scaffolds. a) Construction Site - On or about October 24, 2014, an employee was working from a crawling board (chicken ladder) and a single pole scaffold without having cross bracing on the scaffold poles.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2014-12-18
Abatement Due Date 2014-12-31
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2015-01-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Construction Site - On or about October 24, 2014, the employees had not received scaffold training.
Citation ID 02001
Citaton Type Other
Standard Cited 19260416 E01
Issuance Date 2014-12-18
Abatement Due Date 2014-12-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-14
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used. a) Construction Site - On or about October 24, 2014, A circular skill saw was plugged into an extension cord that had torn outer insulation at the female plug.
Citation ID 02002
Citaton Type Other
Standard Cited 19260451 C02
Issuance Date 2014-12-18
Abatement Due Date 2014-12-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-14
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) Construction Site - On or about October 24, 2014, an employee was working from a crawling board (chicken ladder) and a pole scaffold without having mud sills under each support leg.