Name: | Aztec Masonry, Inc. |
Jurisdiction: | MISSISSIPPI |
Business Type: | Profit Corporation |
Status: | Good Standing |
Effective Date: | 22 Mar 2006 (19 years ago) |
Business ID: | 889058 |
State of Incorporation: | TENNESSEE |
Principal Office Address: | 1310 Rebel Rd. Cordova, TN 38018 |
Name | Role | Address |
---|---|---|
Stallings, Gene | Agent | 68 Vaughn Lane, Olive Branch, MS 38654 |
Name | Role | Address |
---|---|---|
Melchor Olguin | Director | 1310 Rebel Rd., Cordova, TN 38018 |
Olivia Olguin | Director | 1310 Rebel Rd., Cordova, TN 38018 |
Name | Role | Address |
---|---|---|
Melchor Olguin | President | 1310 Rebel Rd., Cordova, TN 38018 |
Name | Role | Address |
---|---|---|
Olivia Olguin | Vice President | 1310 Rebel Rd., Cordova, TN 38018 |
Type | Status | Filed Date | Description |
---|---|---|---|
Annual Report | Filed | 2025-01-27 | Annual Report For Aztec Masonry, Inc. |
Annual Report | Filed | 2024-02-22 | Annual Report For Aztec Masonry, Inc. |
Annual Report | Filed | 2023-02-13 | Annual Report For Aztec Masonry, Inc. |
Annual Report | Filed | 2022-02-10 | Annual Report For Aztec Masonry, Inc. |
Annual Report | Filed | 2021-09-24 | Annual Report For Aztec Masonry, Inc. |
Notice to Dissolve/Revoke | Filed | 2021-09-07 | Notice of Intent to Dissolve: AR: Aztec Masonry, Inc. |
Annual Report | Filed | 2020-09-10 | Annual Report For Aztec Masonry, Inc. |
Notice to Dissolve/Revoke | Filed | 2020-08-28 | Notice to Dissolve/Revoke |
Annual Report | Filed | 2019-09-04 | Annual Report For Aztec Masonry, Inc. |
Notice to Dissolve/Revoke | Filed | 2019-08-22 | Notice to Dissolve/Revoke |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340493329 | 0419400 | 2015-03-25 | 58 MEADOW BROOK DRIVE, HICKORY FLAT, MS, 38633 | |||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1049319 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 C02 |
Issuance Date | 2015-04-08 |
Current Penalty | 2940.0 |
Initial Penalty | 4900.0 |
Final Order | 2015-05-05 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: (a) Jobsite - On or about March 25, 2015 employees used masonry scaffolding without base plates. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2014-11-04 |
Emphasis | N: CTARGET, L: FALL, P: CTARGET |
Case Closed | 2014-12-09 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260701 B |
Issuance Date | 2014-11-18 |
Current Penalty | 816.0 |
Initial Penalty | 1360.0 |
Final Order | 2014-12-08 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: (a) West side of Worksite - On or about November 4, 2014 employees were exposed to impalement hazards while working near or walking near reinforcing steel that was 9 inches to 48 inches high, and they were not protected by caps placed over the ends of the steel. |