Inspection Nr Report ID Date Opened Site Address
338455835 0419400 2013-01-22 120 FLEITAS AVE., PASS CHRISTIAN, MS, 39571
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-01-22
Emphasis P: FALL, L: FALL
Case Closed 2018-10-18

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260405 A02 II I
Issuance Date 2013-02-11
Abatement Due Date 2013-03-01
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2013-03-20
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points: (a) North Entrance - On or about January 22, 2013 employees were exposed to electrical shock hazards while working in the interior of the residence and they were not protected by adequate protection for flexible cords passing through a hole in the north side door.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2013-02-11
Abatement Due Date 2013-03-01
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2013-03-20
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: (a) East Side of Roof - On or about January 22, 2013 employees were exposed to fall hazards while installing a window and standing at the edge of a steep roof. Employees were not protected by guardrail systems with toeboards, safety net systems, or personal fall arrest systems.
Citation ID 02001
Citaton Type Other
Standard Cited 19260405 G02 IV
Issuance Date 2013-02-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-03-20
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) North End of Construction Site - On or about January 22, 2013 employees were exposed to electric shock hazards while working near an energized flexible cord with no strain relief at the outlet plug.