Search icon

S & R Development, Inc

Headquarter

Company Details

Name: S & R Development, Inc
Jurisdiction: MISSISSIPPI
Business Type: Profit Corporation
Status: Good Standing
Effective Date: 30 Jun 2006 (19 years ago)
Business ID: 894787
ZIP code: 39157
County: Madison
State of Incorporation: MISSISSIPPI
Principal Office Address: 115 West Jackson Street, Suite 2DRidgeland, MS 39157

Links between entities

Type Company Name Company Number State
Headquarter of S & R Development, Inc, ALABAMA 000-365-371 ALABAMA

Agent

Name Role Address
Patel, Mitesh S Agent 114 Bridgewater Crossing, Ridgeland, MS 39157

Incorporator

Name Role Address
Patel, Suresh Incorporator 1000 Veterans Memorial Drive, Kosciusko, MS 39090

Director

Name Role Address
Hiren S. Patel Director 114 Bridgewater Crossing, Ridgeland, MS 39157
Mitesh S. Patel Director 114 Bridgewater Crossing, Ridgeland, MS 39157

President

Name Role Address
Hiren S. Patel President 114 Bridgewater Crossing, Ridgeland, MS 39157

Treasurer

Name Role Address
Hiren S. Patel Treasurer 114 Bridgewater Crossing, Ridgeland, MS 39157

Secretary

Name Role Address
Mitesh S. Patel Secretary 114 Bridgewater Crossing, Ridgeland, MS 39157

Vice President

Name Role Address
Mitesh S. Patel Vice President 114 Bridgewater Crossing, Ridgeland, MS 39157

Filings

Type Status Filed Date Description
Annual Report Filed 2025-01-17 Annual Report For S & R Development, Inc
Annual Report Filed 2024-01-30 Annual Report For S & R Development, Inc
Annual Report Filed 2023-04-20 Annual Report For S & R Development, Inc
Annual Report Filed 2022-09-15 Annual Report For S & R Development, Inc
Notice to Dissolve/Revoke Filed 2022-09-05 Notice of Intent to Dissolve: AR: S & R Development, Inc
Annual Report Filed 2021-04-14 Annual Report For S & R Development, Inc
Annual Report Filed 2020-04-01 Annual Report For S & R Development, Inc
Annual Report Filed 2019-01-29 Annual Report For S & R Development, Inc
Annual Report Filed 2018-04-19 Annual Report For S & R Development, Inc
Annual Report Filed 2017-03-21 Annual Report For S & R Development, Inc

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343738092 0419400 2019-01-25 N. STATE ST. AND LORENZ BLVD., JACKSON, MS, 39216
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-01-25
Emphasis L: FALL, N: CTARGET, P: CTARGET
Case Closed 2019-06-21

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B14
Issuance Date 2019-05-20
Abatement Due Date 2019-06-05
Current Penalty 2125.8
Initial Penalty 3543.0
Final Order 2019-06-18
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(14): "Wall openings." Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 m) above the walking/working surface, shall be protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. a. Elevator Shafts - On or about January 25, 2019 the second floor elevator shafts were not adequately guarded to prevent employees from falling into the shafts. The employees were exposed to a 15 foot fall onto concrete.
342317054 0419400 2017-05-04 210 N. FRONTAGE RD., MERIDIAN, MS, 39301
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-05-04
Emphasis L: FALL, P: FALL, L: FORKLIFT
Case Closed 2017-08-24

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2017-08-14
Abatement Due Date 2017-08-29
Current Penalty 1818.0
Initial Penalty 3386.0
Final Order 2017-08-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide. a. Drive Thru Canopy - On or about May 4, 2017 an employee was standing on the top guardrails of a personnel work platform that was supported by a JLG rough terrain forklift.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 F14
Issuance Date 2017-08-14
Abatement Due Date 2017-08-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(14): Makeshift devices, such as but not limited to boxes and barrels, were used on top of scaffold platforms to increase the working level height of employees: a. Drive Thru Canopy - on or about May 4, 2017 a wooden board was placed across the mid rails of a personnel work platform to increase the working height.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02 V
Issuance Date 2017-08-14
Abatement Due Date 2017-08-29
Current Penalty 1095.0
Initial Penalty 2032.0
Final Order 2017-08-24
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(v): The employer used a forklift to support a scaffold platform without ensuring that the entire platform was attached to the fork. a. Drive Thru Canopy - On or about May 4, 2017 a personnel work platform was not secured to the forks of the JLG rough terrain forklift that was used to elevate the work platform.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2017-08-14
Abatement Due Date 2017-08-29
Current Penalty 1095.0
Initial Penalty 2032.0
Final Order 2017-08-24
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment and enclosures was not permanent and continuous. a. Drive Thru Canopy - On or about May 4, 2017 the grounding prong was missing from a 3 outlet power adapter that was plugged into an extension cord.
Citation ID 02001
Citaton Type Other
Standard Cited 19260405 G02 IV
Issuance Date 2017-08-14
Abatement Due Date 2017-08-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-24
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a. Drive Thru Canopy - On or about May 4, 2017 an extension cord female plug did not have strain relief. The outer insulation was pulled from the plug.
341008720 0419400 2015-10-22 210 NORTH FRONTAGE ROAD, MERIDIAN, MS, 39301
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-10-22
Emphasis L: FALL
313629248 0419400 2010-02-16 RIVERWIND EAST DRIVE, PEARL, MS, 39208
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2010-02-16
Emphasis L: FALL, S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT, S: POWERED IND VEHICLE
Case Closed 2010-03-22

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2010-02-19
Abatement Due Date 2010-03-10
Current Penalty 500.0
Initial Penalty 500.0
Nr Instances 1
Nr Exposed 2
Gravity 02
313626442 0419400 2009-08-25 1013 N. GLOSTER, TUPELO, MS, 38804
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2009-08-25
Emphasis S: FALL FROM HEIGHT, L: FALL
Case Closed 2009-12-24

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260028 A
Issuance Date 2009-09-04
Abatement Due Date 2009-09-11
Current Penalty 175.0
Initial Penalty 375.0
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B14
Issuance Date 2009-09-04
Abatement Due Date 2009-09-10
Current Penalty 2025.0
Initial Penalty 4000.0
Nr Instances 1
Nr Exposed 2
Gravity 10
311419568 0419400 2009-04-16 121 HOSPITALITY DRIVE, FLOWOOD, MS, 39232
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2009-04-16
Case Closed 2009-04-22

Date of last update: 21 Mar 2025

Sources: Mississippi Secretary of State