Name: | Jason Morris Construction, LLC |
Jurisdiction: | MISSISSIPPI |
Business Type: | Limited Liability Company |
Status: | Dissolved |
Effective Date: | 22 Aug 2006 (19 years ago) |
Business ID: | 897588 |
ZIP code: | 38655 |
County: | Lafayette |
State of Incorporation: | MISSISSIPPI |
Principal Office Address: | 359 COTTON ROADOXFORD, MS 38655 |
Name | Role | Address |
---|---|---|
FREELAND MARTZ, PLLC | Agent | 302 Enterprise Drive, Suite A, Oxford, MS 38655 |
Name | Role | Address |
---|---|---|
JASON MORRIS | Manager | 359 COTTON ROAD, OXFORD, MS 38655 |
Name | Role | Address |
---|---|---|
JASON MORRIS | Member | 359 COTTON ROAD, OXFORD, MS 38655 |
Type | Status | Filed Date | Description |
---|---|---|---|
Admin Dissolution | Filed | 2024-12-01 | Action of Intent to Dissolve: AR: Jason Morris Construction, LLC |
Notice to Dissolve/Revoke | Filed | 2024-09-01 | Notice of Intent to Dissolve: AR: Jason Morris Construction, LLC |
Annual Report LLC | Filed | 2023-03-09 | Annual Report For Jason Morris Construction, LLC |
Annual Report LLC | Filed | 2022-01-12 | Annual Report For Jason Morris Construction, LLC |
Annual Report LLC | Filed | 2021-02-09 | Annual Report For Jason Morris Construction, LLC |
Annual Report LLC | Filed | 2020-05-13 | Annual Report For Jason Morris Construction, LLC |
Annual Report LLC | Filed | 2019-11-07 | Annual Report For Jason Morris Construction, LLC |
Annual Report LLC | Filed | 2019-11-06 | Annual Report For Jason Morris Construction, LLC |
Notice to Dissolve/Revoke | Filed | 2019-08-22 | Notice to Dissolve/Revoke |
Amendment Form | Filed | 2018-06-12 | Amendment For Jason Morris Construction, LLC |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339661209 | 0419400 | 2014-04-03 | 11105 HWY 6, THAXTON, MS, 38871 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2014-06-11 |
Abatement Due Date | 2014-06-23 |
Current Penalty | 1200.0 |
Initial Penalty | 2000.0 |
Final Order | 2014-06-27 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) Road adjacent to 11105 Hwy 6, Thaxton, MS - On or about April 3, 2014, employees were exposed to fall hazards while working and standing over 8 feet above the floor on the ceiling sub-floor and joists of the inside rooms. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2014-06-11 |
Abatement Due Date | 2014-06-18 |
Current Penalty | 1200.0 |
Initial Penalty | 2000.0 |
Final Order | 2014-06-27 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) Road adjacent to 11105 Hwy 6, Thaxton, MS - On or about April 3, 2014, an employee was working while standing with the right foot on the highest usable step and the left foot on the back cross bracing. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2014-06-11 |
Abatement Due Date | 2014-06-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-06-27 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: Road adjacent to 11105 Hwy 6, Thaxton, MS - On or about April 3, 2014, employees were exposed to fall hazards because of using the top step and the top cap of a 7 foot step ladder. (a) An employee stood on the top step of a step ladder while framing near the top edge of a wall. (b) An employee used a step ladder to descend from the ceiling rafters by stepping on the top cap and top step of a step ladder. |
Date of last update: 06 May 2025
Sources: Company Profile on Mississippi Secretary of State Website