Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2022-07-15 |
Abatement Due Date |
2022-08-08 |
Current Penalty |
5801.0 |
Initial Penalty |
5801.0 |
Final Order |
2022-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1):Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is not fully planked. (a) Rear of house - On or about May 19, 2022 the employer instructed employee to use the welded tubular scaffolding to paint the exterior of building that was not fully planked exposing employees to fall hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 I |
Issuance Date |
2022-07-15 |
Abatement Due Date |
2022-08-08 |
Current Penalty |
5801.0 |
Initial Penalty |
5801.0 |
Final Order |
2022-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1)(i):Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. (a) Rear of house - On or about May 19, 2022 the employer instructed the employee(s) to use the scaffolding that the company erected that has scaffolding wooden planks with gaps between them larger than 1 inch exposing employees to fall hazards. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2022-07-15 |
Abatement Due Date |
2022-08-08 |
Current Penalty |
4144.0 |
Initial Penalty |
4144.0 |
Final Order |
2022-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: (a) Exterior of house wall - On or about May 19, 2022 the employer instructed his employee to use the scaffolding that is missing base plates and mud sills to apply paint to the exterior of the building exposing employee to fall hazards. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 F04 |
Issuance Date |
2022-07-15 |
Abatement Due Date |
2022-08-08 |
Current Penalty |
5801.0 |
Initial Penalty |
5801.0 |
Final Order |
2022-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(4):Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired. (a) West side of house - On or about May 19, 2022 the employer had his employees use the welded tubular scaffolding that has rusted structural sections to apply bricks and paint exposing employees to fall hazards. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2022-07-15 |
Abatement Due Date |
2022-08-08 |
Current Penalty |
5801.0 |
Initial Penalty |
5801.0 |
Final Order |
2022-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level by fall protection established in accordance with paragraphs (g)(1)(i) through (vii) of this section: (a) Exterior house walls - On or about May 19, 2022 the employer instructed his worker to use the scaffolding to apply paint to the exterior of the house wall that is grater than 10 feet high without the use of any fall protection system exposing the employee to fall hazards. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260452 C02 |
Issuance Date |
2022-07-15 |
Abatement Due Date |
2022-08-08 |
Current Penalty |
4144.0 |
Initial Penalty |
4144.0 |
Final Order |
2022-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(c)(2):All brace connections were not secured. (a) Rear of house - On or about May 19, 2022 the employer instructed his employee to use the welded tubular scaffolding to apply paint to the exterior of the house wall where the scaffolding bracing was not secured to the frame exposing employee to fall hazards. |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19260452 C04 |
Issuance Date |
2022-07-15 |
Abatement Due Date |
2022-08-08 |
Current Penalty |
4144.0 |
Initial Penalty |
4144.0 |
Final Order |
2022-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(c)(4):Where uplift could occur which would displace scaffold end frames or panels, the frames or panels were not locked together vertically by pins or equivalent means: (a) Rear and west side of house - On or about May 19, 2022 the employer had his worker(s) use the scaffolding to install bricks and paint the bricks from the scaffolding that is missing locking pins exposing employees to fall hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260454 A |
Issuance Date |
2022-07-15 |
Abatement Due Date |
2022-08-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(a):The employer did not have each employee who performed work on a scaffold be trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used, and to understand the procedures to control or minimize those hazards. (a) Rear and west side of house - On or about May 19, 2022 the employer instructed his employee to use the scaffolding to paint the exterior of the brick wall without receiving training exposing him to fall hazards. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260503 A02 |
Issuance Date |
2022-07-15 |
Abatement Due Date |
2022-08-08 |
Current Penalty |
465.0 |
Initial Penalty |
465.0 |
Final Order |
2022-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2):The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii): (a) Rear and west side of house - On or about May 19, 2022 the employer instructed employees to use the scaffolding to paint the exterior without receiving fall protection training exposing them to fall hazards. |
|