Search icon

D. Carroll Construction, LLC

Headquarter

Company Details

Name: D. Carroll Construction, LLC
Jurisdiction: MISSISSIPPI
Business Type: Limited Liability Company
Status: Good Standing
Effective Date: 24 Sep 2007 (18 years ago)
Business ID: 919655
ZIP code: 38655
County: Lafayette
State of Incorporation: MISSISSIPPI
Principal Office Address: 1420 North LamarOxford, MS 38655
Historical names: Carroll Construction & Development, LLC

Links between entities

Type Company Name Company Number State
Headquarter of D. Carroll Construction, LLC, ALABAMA 000-616-585 ALABAMA

Agent

Name Role Address
Carroll, David Agent 25 Cr 122;PO Box 149, Oxford, MS 38655

Manager

Name Role Address
David Carroll Manager P O BOX 1237, OXFORD, MS 38655

Filings

Type Status Filed Date Description
Annual Report LLC Filed 2024-03-25 Annual Report For D. Carroll Construction, LLC
Annual Report LLC Filed 2023-02-27 Annual Report For D. Carroll Construction, LLC
Annual Report LLC Filed 2022-03-28 Annual Report For D. Carroll Construction, LLC
Annual Report LLC Filed 2021-02-08 Annual Report For D. Carroll Construction, LLC
Annual Report LLC Filed 2020-02-25 Annual Report For D. Carroll Construction, LLC
Annual Report LLC Filed 2019-01-24 Annual Report For D. Carroll Construction, LLC
Annual Report LLC Filed 2018-03-06 Annual Report For D. Carroll Construction, LLC
Annual Report LLC Filed 2017-02-17 Annual Report For D. Carroll Construction, LLC
Annual Report LLC Filed 2016-01-21 Annual Report For D. Carroll Construction, LLC
Annual Report LLC Filed 2015-03-20 Annual Report For D. Carroll Construction, LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341492254 0419400 2016-05-18 1801 E. JACKSON AVE., OXFORD, MS, 38655
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-05-18
Emphasis L: FALL, P: FALL
Case Closed 2018-12-28

Related Activity

Type Inspection
Activity Nr 1155328
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2016-06-27
Abatement Due Date 2016-06-29
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2016-08-03
Nr Instances 8
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) All 8 buildings - On or about May 18, 2016 employees working from second level balconies 12 feet 6 inches high were not protected from falling to a lower level by the use of guardrail systems, safety net systems, or personal fall arrest systems.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2016-06-27
Abatement Due Date 2016-06-29
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2016-08-03
Nr Instances 8
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: (a) All 8 buildings on site - On or about May 18, 2016 employees using stairs not protected with a stairrail system along the unprotected side were exposed to a fall hazard.
341443661 0419400 2016-04-28 300 FAZIO DR., OXFORD, MS, 38655
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-04-28
Emphasis P: CTARGET, N: CTARGET, L: FALL
Case Closed 2023-05-17

Related Activity

Type Inspection
Activity Nr 1144272
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260300 B04 II
Issuance Date 2016-07-19
Abatement Due Date 2016-08-03
Current Penalty 3273.0
Initial Penalty 3273.0
Final Order 2016-08-17
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(4)(ii): The point of operation of machine(s) whose operation exposed an employee to injury was not guarded: a. Second Floor of County Clubhouse building - On or about April 28, 2016 a Sears 10 inch Craftsman table saw did not have a guard for the blade and the electric motor pulley.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2016-07-19
Current Penalty 3273.0
Initial Penalty 3273.0
Final Order 2016-08-17
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. Country Clubhouse Balcony - On or about April 28, 2016 an employee was observed on the balcony containing a guard rail system which lacked the mid rail thereby exposing employees to a fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260602 A09 II
Issuance Date 2016-07-19
Current Penalty 2782.0
Initial Penalty 2782.0
Final Order 2016-08-17
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(a)(9)(ii): Earth moving or compacting equipment which had an obstructed view to the rear was operated in reverse gear; such equipment did not have in operation a reverse signal alarm distinguishable from the surrounding noise level or did an employee signaled that it is safe to do so. a. Southside of Country Clubhouse Building - On or about April 28, 2016 a Bobcat skid-steer loader did not have a working backup alarm. The wires for the backup alarm were cut.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2016-07-19
Current Penalty 1669.0
Initial Penalty 1669.0
Final Order 2016-08-17
Nr Instances 2
Nr Exposed 10
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stair rail system along each unprotected side or edge. a. South Side of Country Clubhouse Building - On or about April 28, 2016, two set of temporary steps lacked standard ailing on one of the open side exposing employees to a fall hazard.
340491760 0419400 2015-03-26 HWY 3 AND LUCUS ST., MOORHEAD, MS, 38761
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-03-26
Emphasis P: CTARGET, N: CTARGET
Case Closed 2015-09-09

Related Activity

Type Inspection
Activity Nr 1049349
Safety Yes
Type Inspection
Activity Nr 1049328
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260405 B01
Issuance Date 2015-04-30
Current Penalty 2618.0
Initial Penalty 2618.0
Final Order 2015-05-27
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed: (a) Construction Site - On or about March 26, 2015 a circuit breaker box was missing one circuit breaker and no panel blank was in place.
315307389 0419400 2012-02-22 110 VALENTOUR ROAD, PEARL, MS, 39208
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-02-22
Emphasis L: EISAOF, L: EISAX, L: FALL, L: FORKLIFT, S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT, S: POWERED IND VEHICLE, S: STRUCK-BY, S: HISPANIC
Case Closed 2012-04-03

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2012-03-26
Abatement Due Date 2012-04-12
Current Penalty 1440.0
Initial Penalty 2400.0
Nr Instances 1
Nr Exposed 1
Gravity 05
315305623 0419400 2011-11-08 110 VALENTOUR ROAD, PEARL, MS, 39208
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2011-11-08
Emphasis L: EISAX, L: FALL, S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT, S: HISPANIC, S: ELECTRICAL
Case Closed 2011-12-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2011-11-29
Abatement Due Date 2011-12-23
Current Penalty 918.0
Initial Penalty 1530.0
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 J01 I
Issuance Date 2011-11-29
Abatement Due Date 2011-12-23
Current Penalty 918.0
Initial Penalty 1530.0
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2011-11-29
Abatement Due Date 2011-12-23
Current Penalty 1530.0
Initial Penalty 2550.0
Nr Instances 2
Nr Exposed 2
Gravity 05
313634321 0419400 2010-11-10 25 CONFEDERATE DR, OXFORD, MS, 38677
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2010-11-10
Emphasis S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT, L: FALL
Case Closed 2010-12-28

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2010-12-06
Abatement Due Date 2010-12-10
Current Penalty 2142.0
Initial Penalty 2142.0
Nr Instances 1
Nr Exposed 1
Gravity 05
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2010-12-06
Abatement Due Date 2010-12-10
Current Penalty 2142.0
Initial Penalty 2142.0
Nr Instances 1
Nr Exposed 1
Gravity 05
313633976 0419400 2010-10-29 HIGHWAY 333 NORTH, GRENADA DAM, GRENADA, MS, 38901
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2010-10-29
Emphasis S: POWERED IND VEHICLE, S: TRENCHING, S: ELECTRICAL, S: COMMERCIAL CONSTR, L: R4STMCON
Case Closed 2010-11-17

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260405 G02 IV
Issuance Date 2010-11-04
Abatement Due Date 2010-11-09
Current Penalty 1606.0
Initial Penalty 1606.0
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 F05 I
Issuance Date 2010-11-04
Abatement Due Date 2010-11-16
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 02002
Citaton Type Other
Standard Cited 19260416 E01
Issuance Date 2010-11-04
Abatement Due Date 2010-11-09
Nr Instances 1
Nr Exposed 1
Gravity 01
313632739 0419400 2010-09-09 HIGHWAY 333, GRENADA, MS, 38901
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2010-09-09
Emphasis S: TRENCHING, S: COMMERCIAL CONSTR, L: R4STMCON, S: POWERED IND VEHICLE
Case Closed 2010-09-13

Date of last update: 22 Mar 2025

Sources: Mississippi Secretary of State